CVE-2018-9086 (GCVE-0-2018-9086)
Vulnerability from cvelistv5
Published
2018-11-16 14:00
Modified
2024-08-05 07:17
Severity ?
Summary
In some Lenovo ThinkServer-branded servers, a command injection vulnerability exists in the BMC firmware download command. This allows a privileged user to download and execute arbitrary code inside the BMC. This can only be exploited by authorized privileged users.
Impacted products
Vendor Product Version
Lenovo ThinkServer BMC Version: unspecified   < varies
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T07:17:51.040Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://support.lenovo.com/us/en/solutions/LEN-23836"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "ThinkServer BMC",
          "vendor": "Lenovo",
          "versions": [
            {
              "lessThan": "varies",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2018-11-16T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "In some Lenovo ThinkServer-branded servers, a command injection vulnerability exists in the BMC firmware download command. This allows a privileged user to download and execute arbitrary code inside the BMC. This can only be exploited by authorized privileged users."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Arbitrary Code Execution",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-11-16T13:57:01",
        "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "shortName": "lenovo"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://support.lenovo.com/us/en/solutions/LEN-23836"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Update BMC firmware"
        }
      ],
      "source": {
        "advisory": "LEN-23836",
        "discovery": "INTERNAL"
      },
      "title": "Legacy Server BMC Remote Command Injection",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "[email protected]",
          "ID": "CVE-2018-9086",
          "STATE": "PUBLIC",
          "TITLE": "Legacy Server BMC Remote Command Injection"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "ThinkServer BMC",
                      "version": {
                        "version_data": [
                          {
                            "affected": "\u003c",
                            "version_affected": "\u003c",
                            "version_value": "varies"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Lenovo"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In some Lenovo ThinkServer-branded servers, a command injection vulnerability exists in the BMC firmware download command. This allows a privileged user to download and execute arbitrary code inside the BMC. This can only be exploited by authorized privileged users."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Arbitrary Code Execution"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.lenovo.com/us/en/solutions/LEN-23836",
              "refsource": "CONFIRM",
              "url": "https://support.lenovo.com/us/en/solutions/LEN-23836"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Update BMC firmware"
          }
        ],
        "source": {
          "advisory": "LEN-23836",
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
    "assignerShortName": "lenovo",
    "cveId": "CVE-2018-9086",
    "datePublished": "2018-11-16T14:00:00",
    "dateReserved": "2018-03-27T00:00:00",
    "dateUpdated": "2024-08-05T07:17:51.040Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2018-9086\",\"sourceIdentifier\":\"[email protected]\",\"published\":\"2018-11-16T14:29:00.457\",\"lastModified\":\"2024-11-21T04:14:56.983\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"In some Lenovo ThinkServer-branded servers, a command injection vulnerability exists in the BMC firmware download command. This allows a privileged user to download and execute arbitrary code inside the BMC. This can only be exploited by authorized privileged users.\"},{\"lang\":\"es\",\"value\":\"En algunos servidores de marca Lenovo ThinkServer, existe una vulnerabilidad de inyecci\u00f3n de comandos en el comando de descarga del firmware de BMC. Esto permite que un usuario privilegiado descargue y ejecute c\u00f3digo arbitrario en el BMC. Esto solo puede ser explotado por usuarios privilegiados autorizados.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"[email protected]\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"[email protected]\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:P/A:P\",\"baseScore\":6.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"[email protected]\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:lenovo:thinkserver_rd340_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"64.00\",\"matchCriteriaId\":\"310C9518-E17E-4E40-9936-98258F89F6F3\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:lenovo:thinkserver_rd340:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6A48E001-1D62-4A25-8C7F-D4691BAEC3DC\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:lenovo:thinkserver_rd440_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"64.00\",\"matchCriteriaId\":\"74FA6345-B9DC-40D2-8F22-33BEA9BE76D9\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:lenovo:thinkserver_rd440:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3ED7B28A-1E10-4011-8250-8E060F74E3CC\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:lenovo:thinkserver_rd640_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"64.00\",\"matchCriteriaId\":\"1A558233-49C4-4CF9-A0D0-4AB2DDCEC458\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:lenovo:thinkserver_rd640:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9E66D761-1400-41AE-AAB7-E54B80B3FAC8\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:lenovo:thinkserver_td340_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"60.00\",\"matchCriteriaId\":\"1E03AAA4-6496-44B0-BBF8-8DDAE1316312\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:lenovo:thinkserver_td340:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"42109D0F-9FDD-4199-A946-64C453B40CFD\"}]}]}],\"references\":[{\"url\":\"https://support.lenovo.com/us/en/solutions/LEN-23836\",\"source\":\"[email protected]\",\"tags\":[\"Patch\",\"Third Party Advisory\"]},{\"url\":\"https://support.lenovo.com/us/en/solutions/LEN-23836\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Third Party Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…
OSZAR »