CVE-2018-9086 (GCVE-0-2018-9086)
Vulnerability from cvelistv5
Published
2018-11-16 14:00
Modified
2024-08-05 07:17
Severity ?
VLAI Severity ?
EPSS score ?
Summary
In some Lenovo ThinkServer-branded servers, a command injection vulnerability exists in the BMC firmware download command. This allows a privileged user to download and execute arbitrary code inside the BMC. This can only be exploited by authorized privileged users.
References
▼ | URL | Tags | |
---|---|---|---|
[email protected] | https://support.lenovo.com/us/en/solutions/LEN-23836 | Patch, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://support.lenovo.com/us/en/solutions/LEN-23836 | Patch, Third Party Advisory |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Lenovo | ThinkServer BMC |
Version: unspecified < varies |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T07:17:51.040Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://support.lenovo.com/us/en/solutions/LEN-23836" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "ThinkServer BMC", "vendor": "Lenovo", "versions": [ { "lessThan": "varies", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "datePublic": "2018-11-16T00:00:00", "descriptions": [ { "lang": "en", "value": "In some Lenovo ThinkServer-branded servers, a command injection vulnerability exists in the BMC firmware download command. This allows a privileged user to download and execute arbitrary code inside the BMC. This can only be exploited by authorized privileged users." } ], "problemTypes": [ { "descriptions": [ { "description": "Arbitrary Code Execution", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-11-16T13:57:01", "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b", "shortName": "lenovo" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://support.lenovo.com/us/en/solutions/LEN-23836" } ], "solutions": [ { "lang": "en", "value": "Update BMC firmware" } ], "source": { "advisory": "LEN-23836", "discovery": "INTERNAL" }, "title": "Legacy Server BMC Remote Command Injection", "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "[email protected]", "ID": "CVE-2018-9086", "STATE": "PUBLIC", "TITLE": "Legacy Server BMC Remote Command Injection" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "ThinkServer BMC", "version": { "version_data": [ { "affected": "\u003c", "version_affected": "\u003c", "version_value": "varies" } ] } } ] }, "vendor_name": "Lenovo" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "In some Lenovo ThinkServer-branded servers, a command injection vulnerability exists in the BMC firmware download command. This allows a privileged user to download and execute arbitrary code inside the BMC. This can only be exploited by authorized privileged users." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Arbitrary Code Execution" } ] } ] }, "references": { "reference_data": [ { "name": "https://support.lenovo.com/us/en/solutions/LEN-23836", "refsource": "CONFIRM", "url": "https://support.lenovo.com/us/en/solutions/LEN-23836" } ] }, "solution": [ { "lang": "en", "value": "Update BMC firmware" } ], "source": { "advisory": "LEN-23836", "discovery": "INTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b", "assignerShortName": "lenovo", "cveId": "CVE-2018-9086", "datePublished": "2018-11-16T14:00:00", "dateReserved": "2018-03-27T00:00:00", "dateUpdated": "2024-08-05T07:17:51.040Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2018-9086\",\"sourceIdentifier\":\"[email protected]\",\"published\":\"2018-11-16T14:29:00.457\",\"lastModified\":\"2024-11-21T04:14:56.983\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"In some Lenovo ThinkServer-branded servers, a command injection vulnerability exists in the BMC firmware download command. This allows a privileged user to download and execute arbitrary code inside the BMC. This can only be exploited by authorized privileged users.\"},{\"lang\":\"es\",\"value\":\"En algunos servidores de marca Lenovo ThinkServer, existe una vulnerabilidad de inyecci\u00f3n de comandos en el comando de descarga del firmware de BMC. Esto permite que un usuario privilegiado descargue y ejecute c\u00f3digo arbitrario en el BMC. Esto solo puede ser explotado por usuarios privilegiados autorizados.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"[email protected]\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"[email protected]\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:P/A:P\",\"baseScore\":6.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"[email protected]\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:lenovo:thinkserver_rd340_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"64.00\",\"matchCriteriaId\":\"310C9518-E17E-4E40-9936-98258F89F6F3\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:lenovo:thinkserver_rd340:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6A48E001-1D62-4A25-8C7F-D4691BAEC3DC\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:lenovo:thinkserver_rd440_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"64.00\",\"matchCriteriaId\":\"74FA6345-B9DC-40D2-8F22-33BEA9BE76D9\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:lenovo:thinkserver_rd440:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3ED7B28A-1E10-4011-8250-8E060F74E3CC\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:lenovo:thinkserver_rd640_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"64.00\",\"matchCriteriaId\":\"1A558233-49C4-4CF9-A0D0-4AB2DDCEC458\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:lenovo:thinkserver_rd640:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9E66D761-1400-41AE-AAB7-E54B80B3FAC8\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:lenovo:thinkserver_td340_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"60.00\",\"matchCriteriaId\":\"1E03AAA4-6496-44B0-BBF8-8DDAE1316312\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:lenovo:thinkserver_td340:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"42109D0F-9FDD-4199-A946-64C453B40CFD\"}]}]}],\"references\":[{\"url\":\"https://support.lenovo.com/us/en/solutions/LEN-23836\",\"source\":\"[email protected]\",\"tags\":[\"Patch\",\"Third Party Advisory\"]},{\"url\":\"https://support.lenovo.com/us/en/solutions/LEN-23836\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Third Party Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…