Vulnerabilites related to siemens - simotion
CVE-2017-2680 (GCVE-0-2017-2680)
Vulnerability from cvelistv5
Published
2017-05-11 01:00
Modified
2024-09-10 09:33
Summary
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.
Impacted products
Vendor Product Version
Siemens Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller Version: All versions < V4.1.1 Patch04
Create a notification for this product.
   Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 Version: All versions < V4.2.1 Patch03
Create a notification for this product.
   Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P Version: All versions < V4.4.0 Patch01
Create a notification for this product.
   Siemens Extension Unit 12" PROFINET Version: All versions < V01.01.01
Create a notification for this product.
   Siemens Extension Unit 15" PROFINET Version: All versions < V01.01.01
Create a notification for this product.
   Siemens Extension Unit 19" PROFINET Version: All versions < V01.01.01
Create a notification for this product.
   Siemens Extension Unit 22" PROFINET Version: All versions < V01.01.01
Create a notification for this product.
   Siemens IE/AS-i Link PN IO Version: All versions
Create a notification for this product.
   Siemens IE/PB-Link (incl. SIPLUS NET variants) Version: All versions < V3.0
Create a notification for this product.
   Siemens SCALANCE M-800 family (incl. S615, MUM-800 and RM1224) Version: All versions < V4.03
Create a notification for this product.
   Siemens SCALANCE W-700 IEEE 802.11n family Version: All versions < V6.1
Create a notification for this product.
   Siemens SCALANCE X-200 family (incl. SIPLUS NET variants) Version: All versions < V5.2.2
Create a notification for this product.
   Siemens SCALANCE X-200IRT family (incl. SIPLUS NET variants) Version: All versions < V5.4.0
Create a notification for this product.
   Siemens SCALANCE X-300 family (incl. X408 and SIPLUS NET variants) Version: All versions < V4.1.0
Create a notification for this product.
   Siemens SCALANCE X408 family Version: All versions < V4.1.0
Create a notification for this product.
   Siemens SCALANCE X414 Version: All versions < V3.10.2
Create a notification for this product.
   Siemens SCALANCE XM-400 family Version: All versions < V6.1
Create a notification for this product.
   Siemens SCALANCE XR-500 family Version: All versions < V6.1
Create a notification for this product.
   Siemens SIMATIC CM 1542-1 Version: All versions < V2.0
Create a notification for this product.
   Siemens SIMATIC CM 1542SP-1 Version: All versions < V1.0.15
Create a notification for this product.
   Siemens SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) Version: All versions < V2.1.82
Create a notification for this product.
   Siemens SIMATIC CP 1243-1 (incl. SIPLUS variants) Version: All versions < V2.1.82
Create a notification for this product.
   Siemens SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) Version: 0   < *
Create a notification for this product.
   Siemens SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) Version: All versions
Create a notification for this product.
   Siemens SIMATIC CP 1243-7 LTE US Version: All versions < V2.1.82
Create a notification for this product.
   Siemens SIMATIC CP 1243-8 IRC Version: All versions < V2.1.82
Create a notification for this product.
   Siemens SIMATIC CP 1243-8 IRC Version: All versions < V2.1.82
Create a notification for this product.
   Siemens SIMATIC CP 1542SP-1 IRC (incl. SIPLUS variants) Version: All versions < V1.0.15
Create a notification for this product.
   Siemens SIMATIC CP 1543-1 (incl. SIPLUS variants) Version: All versions < V2.1
Create a notification for this product.
   Siemens SIMATIC CP 1543SP-1 (incl. SIPLUS variants) Version: All versions < V1.0.15
Create a notification for this product.
   Siemens SIMATIC CP 1604 Version: All versions < V2.7
Create a notification for this product.
   Siemens SIMATIC CP 1616 Version: All versions < V2.7
Create a notification for this product.
   Siemens SIMATIC CP 1626 Version: All versions < V1.1
Create a notification for this product.
   Siemens SIMATIC CP 343-1 (incl. SIPLUS variants) Version: All versions < V3.1.3
Create a notification for this product.
   Siemens SIMATIC CP 343-1 Advanced (incl. SIPLUS variants) Version: All versions
Create a notification for this product.
   Siemens SIMATIC CP 343-1 Lean (incl. SIPLUS variants) Version: All versions < V3.1.3
Create a notification for this product.
   Siemens SIMATIC CP 443-1 (incl. SIPLUS variants) Version: All versions < V3.2.17
Create a notification for this product.
   Siemens SIMATIC CP 443-1 Advanced (incl. SIPLUS variants) Version: All versions < V3.2.17
Create a notification for this product.
   Siemens SIMATIC CP 443-1 OPC UA Version: All versions
Create a notification for this product.
   Siemens SIMATIC DK-16xx PN IO Version: All versions < V2.7
Create a notification for this product.
   Siemens SIMATIC ET 200AL IM 157-1 PN Version: 0   < V1.0.2
Create a notification for this product.
   Siemens SIMATIC ET 200M (incl. SIPLUS variants) Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET 200MP IM 155-5 PN BA Version: 0   < V4.0.1
Create a notification for this product.
   Siemens SIMATIC ET 200MP IM 155-5 PN HF Version: 0   < V4.2.0
Create a notification for this product.
   Siemens SIMATIC ET 200MP IM 155-5 PN ST Version: 0   < V4.1.0
Create a notification for this product.
   Siemens SIMATIC ET 200pro IM 154-3 PN HF Version: 0   < *
Create a notification for this product.
   Siemens SIMATIC ET 200pro IM 154-4 PN HF Version: 0   < *
Create a notification for this product.
   Siemens SIMATIC ET 200SP IM 155-6 PN BA Version: 0   < *
Create a notification for this product.
   Siemens SIMATIC ET 200SP IM 155-6 PN HF Version: 0   < V4.2.0
Create a notification for this product.
   Siemens SIMATIC ET 200SP IM 155-6 PN HS Version: 0   < V4.0.1
Create a notification for this product.
   Siemens SIMATIC ET 200SP IM 155-6 PN ST Version: 0   < V4.1.0
Create a notification for this product.
   Siemens SIMATIC ET 200SP IM 155-6 PN ST BA Version: 0   < V4.1.0
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12 Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12 Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN, 4AO U/I 4xM12 Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12 Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12 Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12 Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12 Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12 Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12 Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12 Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12 Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12 Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN: IO-Link Master Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200S (incl. SIPLUS variants) Version: All versions
Create a notification for this product.
   Siemens SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (incl. SIPLUS variants) Version: All versions < V15.1
Create a notification for this product.
   Siemens SIMATIC MV420 SR-B Version: 0   < V7.0.6
Create a notification for this product.
   Siemens SIMATIC MV420 SR-B Body Version: 0   < V7.0.6
Create a notification for this product.
   Siemens SIMATIC MV420 SR-P Version: 0   < V7.0.6
Create a notification for this product.
   Siemens SIMATIC MV420 SR-P Body Version: 0   < V7.0.6
Create a notification for this product.
   Siemens SIMATIC MV440 HR Version: 0   < V7.0.6
Create a notification for this product.
   Siemens SIMATIC MV440 SR Version: 0   < V7.0.6
Create a notification for this product.
   Siemens SIMATIC MV440 UR Version: 0   < V7.0.6
Create a notification for this product.
   Siemens SIMATIC PN/PN Coupler (incl. SIPLUS NET variants) Version: All versions < V4.0
Create a notification for this product.
   Siemens SIMATIC RF650R Version: All versions < V3.0
Create a notification for this product.
   Siemens SIMATIC RF680R Version: All versions < V3.0
Create a notification for this product.
   Siemens SIMATIC RF685R Version: All versions < V3.0
Create a notification for this product.
   Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) Version: All versions < V4.2.1
Create a notification for this product.
   Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) Version: All versions < V2.1
Create a notification for this product.
   Siemens SIMATIC S7-1500 Software Controller Version: All versions < V2.1
Create a notification for this product.
   Siemens SIMATIC S7-200 SMART Version: All versions < V2.3
Create a notification for this product.
   Siemens SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) Version: 0   < V3.X.14
Create a notification for this product.
   Siemens SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) Version: 0   < V6.0.7
Create a notification for this product.
   Siemens SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants) Version: 0   < V6.0.6
Create a notification for this product.
   Siemens SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) Version: 0   < V7.0.2
Create a notification for this product.
   Siemens SIMATIC S7-410 CPU family (incl. SIPLUS variants) Version: All versions < V8.2
Create a notification for this product.
   Siemens SIMATIC TDC CP51M1 Version: 0   < V1.1.8
Create a notification for this product.
   Siemens SIMATIC TDC CPU555 Version: 0   < V1.1.1
Create a notification for this product.
   Siemens SIMATIC Teleservice Adapter IE Advanced Version: All versions
Create a notification for this product.
   Siemens SIMATIC Teleservice Adapter IE Basic Version: All versions
Create a notification for this product.
   Siemens SIMATIC Teleservice Adapter IE Standard Version: All versions
Create a notification for this product.
   Siemens SIMATIC WinAC RTX 2010 Version: All versions < V2010 SP3
Create a notification for this product.
   Siemens SIMATIC WinAC RTX F 2010 Version: All versions < V2010 SP3
Create a notification for this product.
   Siemens SIMOCODE pro V PROFINET (incl. SIPLUS variants) Version: All versions < V2.0.0
Create a notification for this product.
   Siemens SIMOTION Version: All versions < V4.5 HF1
Create a notification for this product.
   Siemens SIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants) Version: All versions < V4.4 HF26
Create a notification for this product.
   Siemens SINAMICS DCM w. PN Version: All versions < V1.4 SP1 HF5
Create a notification for this product.
   Siemens SINAMICS DCP w. PN Version: All versions < V1.2 HF1
Create a notification for this product.
   Siemens SINAMICS G110M w. PN Version: All versions < V4.7 SP6 HF3
Create a notification for this product.
   Siemens SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants) Version: All versions < V4.7 SP6 HF3
Create a notification for this product.
   Siemens SINAMICS G130 V4.7 w. PN Version: All versions < V4.7 HF27
Create a notification for this product.
   Siemens SINAMICS G130 V4.8 w. PN Version: All versions < V4.8 HF4
Create a notification for this product.
   Siemens SINAMICS G150 V4.7 w. PN Version: V4.7: All versions < V4.7 HF27
Create a notification for this product.
   Siemens SINAMICS G150 V4.8 w. PN Version: All versions < V4.8 HF4
Create a notification for this product.
   Siemens SINAMICS GH150 V4.7 w. PROFINET Version: All versions < V4.7 SP5 HF7
Create a notification for this product.
   Siemens SINAMICS GL150 V4.7 w. PROFINET Version: All versions < V4.8 SP2
Create a notification for this product.
   Siemens SINAMICS GM150 V4.7 w. PROFINET Version: All versions < V4.7 HF31
Create a notification for this product.
   Siemens SINAMICS S110 w. PN Version: All versions < V4.4 SP3 HF5
Create a notification for this product.
   Siemens SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants) Version: All versions < V4.7
Create a notification for this product.
   Siemens SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants) Version: All versions
Create a notification for this product.
   Siemens SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants) Version: All versions < V4.7 HF27
Create a notification for this product.
   Siemens SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants) Version: All versions < V4.8 HF4
Create a notification for this product.
   Siemens SINAMICS S150 V4.7 w. PN Version: All versions < V4.7 HF27
Create a notification for this product.
   Siemens SINAMICS S150 V4.8 w. PN Version: All versions < V4.8 HF4
Create a notification for this product.
   Siemens SINAMICS SL150 V4.7.0 w. PROFINET Version: All versions < V4.7 HF30
Create a notification for this product.
   Siemens SINAMICS SL150 V4.7.4 w. PROFINET Version: All versions < V4.8 SP2
Create a notification for this product.
   Siemens SINAMICS SL150 V4.7.5 w. PROFINET Version: All versions < V4.8 SP2
Create a notification for this product.
   Siemens SINAMICS SM120 V4.7 w. PROFINET Version: All versions < V4.8 SP2
Create a notification for this product.
   Siemens SINAMICS V90 w. PN Version: All versions < V1.01
Create a notification for this product.
   Siemens SINUMERIK 828D V4.5 and prior Version: All versions < V4.5 SP6 HF2
Create a notification for this product.
   Siemens SINUMERIK 828D V4.7 Version: All versions < V4.7 SP4 HF1
Create a notification for this product.
   Siemens SINUMERIK 840D sl V4.5 and prior Version: All versions < V4.5 SP6 HF2
Create a notification for this product.
   Siemens SINUMERIK 840D sl V4.7 Version: All versions < V4.7 SP4 HF1
Create a notification for this product.
   Siemens SIPLUS ET 200MP IM 155-5 PN HF Version: 0   < V4.2.0
Create a notification for this product.
   Siemens SIPLUS ET 200MP IM 155-5 PN HF Version: 0   < V4.2.0
Create a notification for this product.
   Siemens SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL Version: 0   < V4.2.0
Create a notification for this product.
   Siemens SIPLUS ET 200MP IM 155-5 PN ST Version: 0   < V4.1.0
Create a notification for this product.
   Siemens SIPLUS ET 200MP IM 155-5 PN ST TX RAIL Version: 0   < V4.1.0
Create a notification for this product.
   Siemens SIPLUS ET 200SP IM 155-6 PN HF Version: 0   < V4.2.0
Create a notification for this product.
   Siemens SIPLUS ET 200SP IM 155-6 PN HF Version: 0   < V4.2.0
Create a notification for this product.
   Siemens SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL Version: 0   < V4.2.0
Create a notification for this product.
   Siemens SIPLUS ET 200SP IM 155-6 PN ST Version: 0   < V4.1.0
Create a notification for this product.
   Siemens SIPLUS ET 200SP IM 155-6 PN ST BA Version: 0   < V4.1.0
Create a notification for this product.
   Siemens SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL Version: 0   < V4.1.0
Create a notification for this product.
   Siemens SIPLUS ET 200SP IM 155-6 PN ST TX RAIL Version: 0   < V4.1.0
Create a notification for this product.
   Siemens SIRIUS ACT 3SU1 interface module PROFINET Version: All versions < V1.1.0
Create a notification for this product.
   Siemens SIRIUS Motor Starter M200D PROFINET Version: All versions
Create a notification for this product.
   Siemens SIRIUS Soft Starter 3RW44 PN Version: All versions
Create a notification for this product.
   Siemens SITOP PSU8600 PROFINET Version: All versions < V1.2.0
Create a notification for this product.
   Siemens SITOP UPS1600 PROFINET (incl. SIPLUS variants) Version: All versions < V2.2.0
Create a notification for this product.
   Siemens Softnet PROFINET IO for PC-based Windows systems Version: All versions < V14 SP1
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2017-2680",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-09T13:26:04.237652Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-09T13:26:15.327Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T14:02:07.270Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "1038463",
            "tags": [
              "vdb-entry",
              "x_refsource_SECTRACK",
              "x_transferred"
            ],
            "url": "http://www.securitytracker.com/id/1038463"
          },
          {
            "name": "98369",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/98369"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-284673.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.1 Patch04"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.2.1 Patch03"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4.0 Patch01"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Extension Unit 12\" PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V01.01.01"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Extension Unit 15\" PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V01.01.01"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Extension Unit 19\" PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V01.01.01"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Extension Unit 22\" PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V01.01.01"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IE/AS-i Link PN IO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IE/PB-Link (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M-800 family (incl. S615, MUM-800 and RM1224)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.03"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W-700 IEEE 802.11n family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X-200 family (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X-200IRT family (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.4.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X-300 family (incl. X408 and SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X408 family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X414",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.10.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM-400 family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR-500 family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CM 1542-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CM 1542SP-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0.15"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1242-7 V2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1.82"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1.82"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE US",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1.82"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-8 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1.82"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-8 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1.82"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1542SP-1 IRC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0.15"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543-1 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543SP-1 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0.15"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1604",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1616",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1626",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 343-1 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 343-1 Advanced (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 343-1 Lean (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 Advanced (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 OPC UA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC DK-16xx PN IO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200AL IM 157-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.0.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200M (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.0.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM 154-3 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM 154-4 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN HS",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.0.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN ST BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN: IO-Link Master",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200S (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV420 SR-B",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV420 SR-B Body",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV420 SR-P",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV420 SR-P Body",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV440 HR",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV440 SR",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV440 UR",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF650R",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF680R",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF685R",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-200 SMART",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.X.14",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-410 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC TDC CP51M1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.1.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC TDC CPU555",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.1.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Teleservice Adapter IE Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Teleservice Adapter IE Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Teleservice Adapter IE Standard",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinAC RTX 2010",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2010 SP3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinAC RTX F 2010",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2010 SP3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTION",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.5 HF1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4 HF26"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS DCM w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.4 SP1 HF5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS DCP w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.2 HF1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G110M w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP6 HF3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP6 HF3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V4.7 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF27"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V4.8 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V4.7 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "V4.7: All versions \u003c V4.7 HF27"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V4.8 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GH150 V4.7 w. PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP5 HF7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GL150 V4.7 w. PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GM150 V4.7 w. PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF31"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S110 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4 SP3 HF5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF27"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V4.7 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF27"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V4.8 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SL150 V4.7.0 w. PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF30"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SL150 V4.7.4 w. PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SL150 V4.7.5 w. PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SM120 V4.7 w. PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS V90 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.01"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK 828D V4.5 and prior",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.5 SP6 HF2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK 828D V4.7",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP4 HF1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK 840D sl V4.5 and prior",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.5 SP6 HF2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK 840D sl V4.7",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP4 HF1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIRIUS ACT 3SU1 interface module PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIRIUS Motor Starter M200D PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIRIUS Soft Starter 3RW44 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SITOP PSU8600 PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SITOP UPS1600 PROFINET (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Softnet PROFINET IO for PC-based Windows systems",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400: Uncontrolled Resource Consumption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-10T09:33:18.492Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "name": "1038463",
          "tags": [
            "vdb-entry",
            "x_refsource_SECTRACK"
          ],
          "url": "http://www.securitytracker.com/id/1038463"
        },
        {
          "name": "98369",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/98369"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-284673.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2017-2680",
    "datePublished": "2017-05-11T01:00:00",
    "dateReserved": "2016-12-01T00:00:00",
    "dateUpdated": "2024-09-10T09:33:18.492Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-10923 (GCVE-0-2019-10923)
Vulnerability from cvelistv5
Published
2019-10-10 13:49
Modified
2025-02-11 10:26
Summary
An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation.
Impacted products
Vendor Product Version
Siemens Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller Version: All versions < V4.1.1 Patch 05
Create a notification for this product.
   Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 Version: All versions < V4.5.0 Patch 01
Create a notification for this product.
   Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P Version: All versions < V4.5.0
Create a notification for this product.
   Siemens SCALANCE X-200IRT family (incl. SIPLUS NET variants) Version: All versions < V5.2.1
Create a notification for this product.
   Siemens SIMATIC CP 1604 Version: All versions < V2.8
Create a notification for this product.
   Siemens SIMATIC CP 1616 Version: All versions < V2.8
Create a notification for this product.
   Siemens SIMATIC ET 200M (incl. SIPLUS variants) Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET 200MP IM 155-5 PN HF Version: 0   < V4.2.0
Create a notification for this product.
   Siemens SIMATIC ET 200MP IM 155-5 PN ST Version: 0   < V4.1.0
Create a notification for this product.
   Siemens SIMATIC ET 200pro IM 154-3 PN HF Version: 0   < *
Create a notification for this product.
   Siemens SIMATIC ET 200pro IM 154-4 PN HF Version: 0   < *
Create a notification for this product.
   Siemens SIMATIC ET 200pro IM 154-8 PN/DP CPU Version: All versions < V3.2.17
Create a notification for this product.
   Siemens SIMATIC ET 200pro IM 154-8F PN/DP CPU Version: All versions < V3.2.17
Create a notification for this product.
   Siemens SIMATIC ET 200pro IM 154-8FX PN/DP CPU Version: All versions < V3.2.17
Create a notification for this product.
   Siemens SIMATIC ET 200S IM 151-8 PN/DP CPU Version: All versions < V3.2.17
Create a notification for this product.
   Siemens SIMATIC ET 200S IM 151-8F PN/DP CPU Version: All versions < V3.2.17
Create a notification for this product.
   Siemens SIMATIC ET 200SP IM 155-6 PN HF Version: 0   < V4.2.0
Create a notification for this product.
   Siemens SIMATIC ET 200SP IM 155-6 PN ST Version: 0   < V4.1.0
Create a notification for this product.
   Siemens SIMATIC ET 200SP IM 155-6 PN ST BA Version: 0   < V4.1.0
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12 Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12 Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN, 4AO U/I 4xM12 Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12 Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12 Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12 Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12 Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12 Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12 Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12 Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12 Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12 Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN: IO-Link Master Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200S (incl. SIPLUS variants) Version: All versions
Create a notification for this product.
   Siemens SIMATIC PN/PN Coupler (incl. SIPLUS NET variants) Version: All versions
Create a notification for this product.
   Siemens SIMATIC S7-300 CPU 314C-2 PN/DP Version: All versions < V3.2.17
Create a notification for this product.
   Siemens SIMATIC S7-300 CPU 315-2 PN/DP Version: All versions < V3.2.17
Create a notification for this product.
   Siemens SIMATIC S7-300 CPU 315F-2 PN/DP Version: All versions < V3.2.17
Create a notification for this product.
   Siemens SIMATIC S7-300 CPU 315T-3 PN/DP Version: All versions < V3.2.17
Create a notification for this product.
   Siemens SIMATIC S7-300 CPU 317-2 PN/DP Version: All versions < V3.2.17
Create a notification for this product.
   Siemens SIMATIC S7-300 CPU 317F-2 PN/DP Version: All versions < V3.2.17
Create a notification for this product.
   Siemens SIMATIC S7-300 CPU 317T-3 PN/DP Version: All versions < V3.2.17
Create a notification for this product.
   Siemens SIMATIC S7-300 CPU 317TF-3 PN/DP Version: All versions < V3.2.17
Create a notification for this product.
   Siemens SIMATIC S7-300 CPU 319-3 PN/DP Version: All versions < V3.2.17
Create a notification for this product.
   Siemens SIMATIC S7-300 CPU 319F-3 PN/DP Version: All versions < V3.2.17
Create a notification for this product.
   Siemens SIMATIC S7-400 CPU 412-2 PN V7 Version: 0   < V7.0.3
Create a notification for this product.
   Siemens SIMATIC S7-400 CPU 414-3 PN/DP V7 Version: 0   < V7.0.3
Create a notification for this product.
   Siemens SIMATIC S7-400 CPU 414F-3 PN/DP V7 Version: 0   < V7.0.3
Create a notification for this product.
   Siemens SIMATIC S7-400 CPU 416-3 PN/DP V7 Version: 0   < V7.0.3
Create a notification for this product.
   Siemens SIMATIC S7-400 CPU 416F-3 PN/DP V7 Version: 0   < V7.0.3
Create a notification for this product.
   Siemens SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) Version: 0   < *
Create a notification for this product.
   Siemens SIMATIC WinAC RTX 2010 Version: All versions < V2010 SP3
Create a notification for this product.
   Siemens SIMATIC WinAC RTX F 2010 Version: All versions < V2010 SP3
Create a notification for this product.
   Siemens SIMOTION Version: All versions
Create a notification for this product.
   Siemens SINAMICS DCM Version: All versions < V1.5 HF1
Create a notification for this product.
   Siemens SINAMICS DCP Version: All versions < V1.3
Create a notification for this product.
   Siemens SINAMICS G110M V4.7 Control Unit Version: All versions < V4.7 SP10 HF5
Create a notification for this product.
   Siemens SINAMICS G120 V4.7 Control Unit (incl. SIPLUS variants) Version: All versions < V4.7 SP10 HF5
Create a notification for this product.
   Siemens SINAMICS G130 Version: 0   < V4.7 HF29
Create a notification for this product.
   Siemens SINAMICS G150 Version: 0   < V4.7 HF29
Create a notification for this product.
   Siemens SINAMICS GH150 V4.7 Control Unit Version: All versions
Create a notification for this product.
   Siemens SINAMICS GL150 V4.7 Control Unit Version: All versions
Create a notification for this product.
   Siemens SINAMICS GM150 V4.7 Control Unit Version: All versions
Create a notification for this product.
   Siemens SINAMICS S110 Control Unit Version: All versions
Create a notification for this product.
   Siemens SINAMICS S120 V4.7 Control Unit and CBE20 (incl. SIPLUS variants) Version: All versions < V4.7 HF34
Create a notification for this product.
   Siemens SINAMICS S150 Version: 0   < V4.7 HF29
Create a notification for this product.
   Siemens SINAMICS SL150 V4.7 Control Unit Version: All versions < V4.7 HF33
Create a notification for this product.
   Siemens SINAMICS SM120 V4.7 Control Unit Version: All versions
Create a notification for this product.
   Siemens SINUMERIK 828D Version: All versions < V4.8 SP5
Create a notification for this product.
   Siemens SINUMERIK 840D sl Version: All versions < V4.8 SP5
Create a notification for this product.
   Siemens SIPLUS ET 200MP IM 155-5 PN HF Version: 0   < V4.2.0
Create a notification for this product.
   Siemens SIPLUS ET 200MP IM 155-5 PN HF Version: 0   < V4.2.0
Create a notification for this product.
   Siemens SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL Version: 0   < V4.2.0
Create a notification for this product.
   Siemens SIPLUS ET 200MP IM 155-5 PN ST Version: 0   < V4.1.0
Create a notification for this product.
   Siemens SIPLUS ET 200MP IM 155-5 PN ST TX RAIL Version: 0   < V4.1.0
Create a notification for this product.
   Siemens SIPLUS ET 200S IM 151-8 PN/DP CPU Version: All versions < V3.2.17
Create a notification for this product.
   Siemens SIPLUS ET 200S IM 151-8F PN/DP CPU Version: All versions < V3.2.17
Create a notification for this product.
   Siemens SIPLUS ET 200SP IM 155-6 PN HF Version: 0   < V4.2.0
Create a notification for this product.
   Siemens SIPLUS ET 200SP IM 155-6 PN HF Version: 0   < V4.2.0
Create a notification for this product.
   Siemens SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL Version: 0   < V4.2.0
Create a notification for this product.
   Siemens SIPLUS ET 200SP IM 155-6 PN ST Version: 0   < V4.1.0
Create a notification for this product.
   Siemens SIPLUS ET 200SP IM 155-6 PN ST BA Version: 0   < V4.1.0
Create a notification for this product.
   Siemens SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL Version: 0   < V4.1.0
Create a notification for this product.
   Siemens SIPLUS ET 200SP IM 155-6 PN ST TX RAIL Version: 0   < V4.1.0
Create a notification for this product.
   Siemens SIPLUS S7-300 CPU 314C-2 PN/DP Version: All versions < V3.3.17
Create a notification for this product.
   Siemens SIPLUS S7-300 CPU 315-2 PN/DP Version: All versions < V3.2.17
Create a notification for this product.
   Siemens SIPLUS S7-300 CPU 315F-2 PN/DP Version: All versions < V3.2.17
Create a notification for this product.
   Siemens SIPLUS S7-300 CPU 317-2 PN/DP Version: All versions < V3.2.17
Create a notification for this product.
   Siemens SIPLUS S7-300 CPU 317F-2 PN/DP Version: All versions < V3.2.17
Create a notification for this product.
   Siemens SIPLUS S7-400 CPU 414-3 PN/DP V7 Version: 0   < V7.0.3
Create a notification for this product.
   Siemens SIPLUS S7-400 CPU 416-3 PN/DP V7 Version: 0   < V7.0.3
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T22:40:15.265Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-349422.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.1 Patch 05"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.5.0 Patch 01"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X-200IRT family (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1604",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1616",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200M (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM 154-3 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM 154-4 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM 154-8 PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM 154-8F PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM 154-8FX PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200S IM 151-8 PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200S IM 151-8F PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN ST BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN: IO-Link Master",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200S (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 314C-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 315-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 315F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 315T-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317T-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317TF-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 319-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 319F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 CPU 412-2 PN V7",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 CPU 414-3 PN/DP V7",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 CPU 414F-3 PN/DP V7",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 CPU 416-3 PN/DP V7",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 CPU 416F-3 PN/DP V7",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinAC RTX 2010",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2010 SP3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinAC RTX F 2010",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2010 SP3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTION",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS DCM",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.5 HF1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS DCP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G110M V4.7 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP10 HF5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G120 V4.7 Control Unit (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP10 HF5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.7 HF29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.7 HF29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GH150 V4.7 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GL150 V4.7 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GM150 V4.7 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S110 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.7 Control Unit and CBE20 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF34"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.7 HF29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SL150 V4.7 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF33"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SM120 V4.7 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK 828D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK 840D sl",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200S IM 151-8 PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200S IM 151-8F PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 314C-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 315-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 315F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 317-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 317F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-400 CPU 414-3 PN/DP V7",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-400 CPU 416-3 PN/DP V7",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400: Uncontrolled Resource Consumption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-11T10:26:23.281Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-349422.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-349422.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-10923",
    "datePublished": "2019-10-10T13:49:24",
    "dateReserved": "2019-04-08T00:00:00",
    "dateUpdated": "2025-02-11T10:26:23.281Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-2681 (GCVE-0-2017-2681)
Vulnerability from cvelistv5
Published
2017-05-11 10:00
Modified
2024-09-10 09:33
Summary
Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.
Impacted products
Vendor Product Version
Siemens Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller Version: All versions < V4.1.1 Patch04
Create a notification for this product.
   Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 Version: All versions < V4.2.1 Patch03
Create a notification for this product.
   Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P Version: All versions < V4.4.0 Patch01
Create a notification for this product.
   Siemens IE/AS-i Link PN IO Version: All versions
Create a notification for this product.
   Siemens IE/PB-Link (incl. SIPLUS NET variants) Version: All versions < V3.0
Create a notification for this product.
   Siemens SCALANCE M-800 family (incl. S615, MUM-800 and RM1224) Version: All versions < V4.03
Create a notification for this product.
   Siemens SCALANCE W-700 IEEE 802.11n family Version: All versions < V6.1
Create a notification for this product.
   Siemens SCALANCE X-200 family (incl. SIPLUS NET variants) Version: All versions < V5.2.2
Create a notification for this product.
   Siemens SCALANCE X-200IRT family (incl. SIPLUS NET variants) Version: All versions < V5.4.0
Create a notification for this product.
   Siemens SCALANCE X-300 family (incl. X408 and SIPLUS NET variants) Version: All versions < V4.1.0
Create a notification for this product.
   Siemens SCALANCE X408 family Version: All versions < V4.1.0
Create a notification for this product.
   Siemens SCALANCE X414 Version: All versions < V3.10.2
Create a notification for this product.
   Siemens SCALANCE XM-400 family Version: All versions < V6.1
Create a notification for this product.
   Siemens SCALANCE XR-500 family Version: All versions < V6.1
Create a notification for this product.
   Siemens SIMATIC CM 1542-1 Version: All versions < V2.0
Create a notification for this product.
   Siemens SIMATIC CM 1542SP-1 Version: All versions < V1.0.15
Create a notification for this product.
   Siemens SIMATIC CP 1243-1 (incl. SIPLUS variants) Version: All versions < V2.1.82
Create a notification for this product.
   Siemens SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) Version: 0   < *
Create a notification for this product.
   Siemens SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) Version: All versions
Create a notification for this product.
   Siemens SIMATIC CP 1243-8 IRC Version: All versions < V2.1.82
Create a notification for this product.
   Siemens SIMATIC CP 1542SP-1 IRC (incl. SIPLUS variants) Version: All versions < V1.0.15
Create a notification for this product.
   Siemens SIMATIC CP 1543-1 (incl. SIPLUS variants) Version: All versions < V2.1
Create a notification for this product.
   Siemens SIMATIC CP 1543SP-1 (incl. SIPLUS variants) Version: All versions < V1.0.15
Create a notification for this product.
   Siemens SIMATIC CP 1604 Version: All versions < V2.7
Create a notification for this product.
   Siemens SIMATIC CP 1616 Version: All versions < V2.7
Create a notification for this product.
   Siemens SIMATIC CP 343-1 (incl. SIPLUS variants) Version: All versions < V3.1.3
Create a notification for this product.
   Siemens SIMATIC CP 343-1 Advanced (incl. SIPLUS variants) Version: All versions
Create a notification for this product.
   Siemens SIMATIC CP 343-1 Lean (incl. SIPLUS variants) Version: All versions < V3.1.3
Create a notification for this product.
   Siemens SIMATIC CP 443-1 (incl. SIPLUS variants) Version: All versions < V3.2.17
Create a notification for this product.
   Siemens SIMATIC CP 443-1 Advanced (incl. SIPLUS variants) Version: All versions < V3.2.17
Create a notification for this product.
   Siemens SIMATIC CP 443-1 OPC UA Version: All versions
Create a notification for this product.
   Siemens SIMATIC DK-16xx PN IO Version: All versions < V2.7
Create a notification for this product.
   Siemens SIMATIC ET 200AL IM 157-1 PN Version: 0   < V1.0.2
Create a notification for this product.
   Siemens SIMATIC ET 200M (incl. SIPLUS variants) Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET 200MP IM 155-5 PN BA Version: 0   < V4.0.1
Create a notification for this product.
   Siemens SIMATIC ET 200MP IM 155-5 PN HF Version: 0   < V4.2.0
Create a notification for this product.
   Siemens SIMATIC ET 200MP IM 155-5 PN ST Version: 0   < V4.1.0
Create a notification for this product.
   Siemens SIMATIC ET 200pro IM 154-3 PN HF Version: 0   < *
Create a notification for this product.
   Siemens SIMATIC ET 200pro IM 154-4 PN HF Version: 0   < *
Create a notification for this product.
   Siemens SIMATIC ET 200SP IM 155-6 PN BA Version: 0   < *
Create a notification for this product.
   Siemens SIMATIC ET 200SP IM 155-6 PN HF Version: 0   < V4.2.0
Create a notification for this product.
   Siemens SIMATIC ET 200SP IM 155-6 PN HS Version: 0   < V4.0.1
Create a notification for this product.
   Siemens SIMATIC ET 200SP IM 155-6 PN ST Version: 0   < V4.1.0
Create a notification for this product.
   Siemens SIMATIC ET 200SP IM 155-6 PN ST BA Version: 0   < V4.1.0
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12 Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12 Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN, 4AO U/I 4xM12 Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12 Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12 Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12 Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12 Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12 Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12 Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12 Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12 Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12 Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200ecoPN: IO-Link Master Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET200S (incl. SIPLUS variants) Version: All versions
Create a notification for this product.
   Siemens SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (incl. SIPLUS variants) Version: All versions < V15.1
Create a notification for this product.
   Siemens SIMATIC MV420 SR-B Version: 0   < V7.0.6
Create a notification for this product.
   Siemens SIMATIC MV420 SR-B Body Version: 0   < V7.0.6
Create a notification for this product.
   Siemens SIMATIC MV420 SR-P Version: 0   < V7.0.6
Create a notification for this product.
   Siemens SIMATIC MV420 SR-P Body Version: 0   < V7.0.6
Create a notification for this product.
   Siemens SIMATIC MV440 HR Version: 0   < V7.0.6
Create a notification for this product.
   Siemens SIMATIC MV440 SR Version: 0   < V7.0.6
Create a notification for this product.
   Siemens SIMATIC MV440 UR Version: 0   < V7.0.6
Create a notification for this product.
   Siemens SIMATIC PN/PN Coupler (incl. SIPLUS NET variants) Version: All versions < V4.0
Create a notification for this product.
   Siemens SIMATIC RF650R Version: All versions < V3.0
Create a notification for this product.
   Siemens SIMATIC RF680R Version: All versions < V3.0
Create a notification for this product.
   Siemens SIMATIC RF685R Version: All versions < V3.0
Create a notification for this product.
   Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) Version: All versions < V4.2.1
Create a notification for this product.
   Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) Version: All versions < V2.1
Create a notification for this product.
   Siemens SIMATIC S7-1500 Software Controller Version: All versions < V2.1
Create a notification for this product.
   Siemens SIMATIC S7-200 SMART Version: All versions < V2.3
Create a notification for this product.
   Siemens SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) Version: 0   < V3.X.14
Create a notification for this product.
   Siemens SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) Version: 0   < V6.0.7
Create a notification for this product.
   Siemens SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants) Version: 0   < V6.0.6
Create a notification for this product.
   Siemens SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) Version: 0   < V7.0.2
Create a notification for this product.
   Siemens SIMATIC S7-410 CPU family (incl. SIPLUS variants) Version: All versions < V8.2
Create a notification for this product.
   Siemens SIMATIC TDC CP51M1 Version: 0   < V1.1.8
Create a notification for this product.
   Siemens SIMATIC TDC CPU555 Version: 0   < V1.1.1
Create a notification for this product.
   Siemens SIMATIC Teleservice Adapter IE Advanced Version: All versions
Create a notification for this product.
   Siemens SIMATIC Teleservice Adapter IE Basic Version: All versions
Create a notification for this product.
   Siemens SIMATIC Teleservice Adapter IE Standard Version: All versions
Create a notification for this product.
   Siemens SIMATIC WinAC RTX 2010 Version: All versions < V2010 SP3
Create a notification for this product.
   Siemens SIMATIC WinAC RTX F 2010 Version: All versions < V2010 SP3
Create a notification for this product.
   Siemens SIMOCODE pro V PROFINET (incl. SIPLUS variants) Version: All versions < V2.0.0
Create a notification for this product.
   Siemens SIMOTION Version: All versions < V4.5 HF1
Create a notification for this product.
   Siemens SINAMICS DCM w. PN Version: All versions < V1.4 SP1 HF5
Create a notification for this product.
   Siemens SINAMICS DCP w. PN Version: All versions < V1.2 HF1
Create a notification for this product.
   Siemens SINAMICS G110M w. PN Version: All versions < V4.7 SP6 HF3
Create a notification for this product.
   Siemens SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants) Version: All versions < V4.7 SP6 HF3
Create a notification for this product.
   Siemens SINAMICS G130 V4.7 w. PN Version: All versions < V4.7 HF27
Create a notification for this product.
   Siemens SINAMICS G130 V4.8 w. PN Version: All versions < V4.8 HF4
Create a notification for this product.
   Siemens SINAMICS G150 V4.7 w. PN Version: V4.7: All versions < V4.7 HF27
Create a notification for this product.
   Siemens SINAMICS G150 V4.8 w. PN Version: All versions < V4.8 HF4
Create a notification for this product.
   Siemens SINAMICS S110 w. PN Version: All versions < V4.4 SP3 HF5
Create a notification for this product.
   Siemens SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants) Version: All versions < V4.7
Create a notification for this product.
   Siemens SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants) Version: All versions
Create a notification for this product.
   Siemens SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants) Version: All versions < V4.7 HF27
Create a notification for this product.
   Siemens SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants) Version: All versions < V4.8 HF4
Create a notification for this product.
   Siemens SINAMICS S150 V4.7 w. PN Version: All versions < V4.7 HF27
Create a notification for this product.
   Siemens SINAMICS S150 V4.8 w. PN Version: All versions < V4.8 HF4
Create a notification for this product.
   Siemens SINAMICS V90 w. PN Version: All versions < V1.01
Create a notification for this product.
   Siemens SINUMERIK 828D V4.5 and prior Version: All versions < V4.5 SP6 HF2
Create a notification for this product.
   Siemens SINUMERIK 828D V4.7 Version: All versions < V4.7 SP4 HF1
Create a notification for this product.
   Siemens SINUMERIK 840D sl V4.5 and prior Version: All versions < V4.5 SP6 HF2
Create a notification for this product.
   Siemens SINUMERIK 840D sl V4.7 Version: All versions < V4.7 SP4 HF1
Create a notification for this product.
   Siemens SIPLUS ET 200MP IM 155-5 PN HF Version: 0   < V4.2.0
Create a notification for this product.
   Siemens SIPLUS ET 200MP IM 155-5 PN HF Version: 0   < V4.2.0
Create a notification for this product.
   Siemens SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL Version: 0   < V4.2.0
Create a notification for this product.
   Siemens SIPLUS ET 200MP IM 155-5 PN ST Version: 0   < V4.1.0
Create a notification for this product.
   Siemens SIPLUS ET 200MP IM 155-5 PN ST TX RAIL Version: 0   < V4.1.0
Create a notification for this product.
   Siemens SIPLUS ET 200SP IM 155-6 PN HF Version: 0   < V4.2.0
Create a notification for this product.
   Siemens SIPLUS ET 200SP IM 155-6 PN HF Version: 0   < V4.2.0
Create a notification for this product.
   Siemens SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL Version: 0   < V4.2.0
Create a notification for this product.
   Siemens SIPLUS ET 200SP IM 155-6 PN ST Version: 0   < V4.1.0
Create a notification for this product.
   Siemens SIPLUS ET 200SP IM 155-6 PN ST BA Version: 0   < V4.1.0
Create a notification for this product.
   Siemens SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL Version: 0   < V4.1.0
Create a notification for this product.
   Siemens SIPLUS ET 200SP IM 155-6 PN ST TX RAIL Version: 0   < V4.1.0
Create a notification for this product.
   Siemens SIRIUS ACT 3SU1 interface module PROFINET Version: All versions < V1.1.0
Create a notification for this product.
   Siemens SIRIUS Motor Starter M200D PROFINET Version: All versions
Create a notification for this product.
   Siemens SIRIUS Soft Starter 3RW44 PN Version: All versions
Create a notification for this product.
   Siemens SITOP PSU8600 PROFINET Version: All versions < V1.2.0
Create a notification for this product.
   Siemens SITOP UPS1600 PROFINET (incl. SIPLUS variants) Version: All versions < V2.2.0
Create a notification for this product.
   Siemens Softnet PROFINET IO for PC-based Windows systems Version: All versions < V14 SP1
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2017-2681",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-23T20:22:19.045364Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-23T20:22:26.181Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T14:02:07.386Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "1038463",
            "tags": [
              "vdb-entry",
              "x_refsource_SECTRACK",
              "x_transferred"
            ],
            "url": "http://www.securitytracker.com/id/1038463"
          },
          {
            "name": "98369",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/98369"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.1 Patch04"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.2.1 Patch03"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4.0 Patch01"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IE/AS-i Link PN IO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IE/PB-Link (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M-800 family (incl. S615, MUM-800 and RM1224)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.03"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W-700 IEEE 802.11n family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X-200 family (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X-200IRT family (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.4.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X-300 family (incl. X408 and SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X408 family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X414",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.10.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM-400 family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR-500 family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CM 1542-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CM 1542SP-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0.15"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1.82"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-8 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1.82"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1542SP-1 IRC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0.15"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543-1 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543SP-1 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0.15"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1604",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1616",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 343-1 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 343-1 Advanced (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 343-1 Lean (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 Advanced (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 OPC UA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC DK-16xx PN IO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200AL IM 157-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.0.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200M (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.0.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM 154-3 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM 154-4 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN HS",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.0.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN ST BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN: IO-Link Master",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200S (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV420 SR-B",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV420 SR-B Body",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV420 SR-P",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV420 SR-P Body",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV440 HR",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV440 SR",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV440 UR",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF650R",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF680R",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF685R",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-200 SMART",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.X.14",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-410 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC TDC CP51M1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.1.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC TDC CPU555",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.1.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Teleservice Adapter IE Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Teleservice Adapter IE Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Teleservice Adapter IE Standard",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinAC RTX 2010",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2010 SP3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinAC RTX F 2010",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2010 SP3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTION",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.5 HF1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS DCM w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.4 SP1 HF5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS DCP w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.2 HF1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G110M w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP6 HF3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP6 HF3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V4.7 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF27"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V4.8 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V4.7 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "V4.7: All versions \u003c V4.7 HF27"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V4.8 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S110 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4 SP3 HF5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF27"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V4.7 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF27"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V4.8 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS V90 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.01"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK 828D V4.5 and prior",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.5 SP6 HF2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK 828D V4.7",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP4 HF1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK 840D sl V4.5 and prior",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.5 SP6 HF2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK 840D sl V4.7",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP4 HF1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIRIUS ACT 3SU1 interface module PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIRIUS Motor Starter M200D PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIRIUS Soft Starter 3RW44 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SITOP PSU8600 PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SITOP UPS1600 PROFINET (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Softnet PROFINET IO for PC-based Windows systems",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400: Uncontrolled Resource Consumption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-10T09:33:20.658Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "name": "1038463",
          "tags": [
            "vdb-entry",
            "x_refsource_SECTRACK"
          ],
          "url": "http://www.securitytracker.com/id/1038463"
        },
        {
          "name": "98369",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/98369"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2017-2681",
    "datePublished": "2017-05-11T10:00:00",
    "dateReserved": "2016-12-01T00:00:00",
    "dateUpdated": "2024-09-10T09:33:20.658Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

var-201212-0032
Vulnerability from variot

Memory leak in Siemens Automation License Manager (ALM) 4.x and 5.x before 5.2 allows remote attackers to cause a denial of service (memory consumption) via crafted packets. The Siemens Automation License Manager is the certificate management software used by various Siemens software products. The following products are affected by this vulnerability: SIMATIC (eg STEP 7) SIMATIC HMI (eg WinCC, WinCC flexible) SIMATIC PCS 7 SIMOTION (eg Scout) SIMATIC NET SINAMICS (eg Starter) SIMOCODE. Successful exploits will cause an affected application to cause a memory leakage and terminate the application, denying service to legitimate users

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201212-0032",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "automation license manager",
        "scope": "eq",
        "trust": 1.9,
        "vendor": "siemens",
        "version": "4.0"
      },
      {
        "model": "automation license manager",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "automation license manager",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "5.0"
      },
      {
        "model": "automation license manager",
        "scope": "eq",
        "trust": 1.1,
        "vendor": "siemens",
        "version": "5.2"
      },
      {
        "model": "automation license manager",
        "scope": "lt",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "5.x"
      },
      {
        "model": "automation license manager",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "4.x"
      },
      {
        "model": "automation license manager",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.4,
        "vendor": "automation license manager",
        "version": "5.1"
      },
      {
        "model": "sinamics",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simotion",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simocode",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic pcs7 sp2",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "7.1"
      },
      {
        "model": "simatic net",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic step",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "75.5.2"
      },
      {
        "model": "simatic step",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "75.5.1"
      },
      {
        "model": "simatic step",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "75.5"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "automation license manager",
        "version": "4.0"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "automation license manager",
        "version": "5.0"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "2d96ffb0-2353-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-7524"
      },
      {
        "db": "BID",
        "id": "56954"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-005759"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201212-250"
      },
      {
        "db": "NVD",
        "id": "CVE-2012-4691"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:siemens:automation_license_manager",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-005759"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "CERT",
    "sources": [
      {
        "db": "BID",
        "id": "56954"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201212-250"
      }
    ],
    "trust": 0.9
  },
  "cve": "CVE-2012-4691",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "[email protected]",
            "availabilityImpact": "PARTIAL",
            "baseScore": 3.3,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "id": "CVE-2012-4691",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "LOW",
            "trust": 1.8,
            "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 3.3,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "id": "2d96ffb0-2353-11e6-abef-000c29c66e3d",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "LOW",
            "trust": 0.2,
            "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 3.3,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "id": "VHN-57972",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "LOW",
            "trust": 0.1,
            "vectorString": "AV:A/AC:L/AU:N/C:N/I:N/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "[email protected]",
            "id": "CVE-2012-4691",
            "trust": 1.0,
            "value": "LOW"
          },
          {
            "author": "NVD",
            "id": "CVE-2012-4691",
            "trust": 0.8,
            "value": "Low"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201212-250",
            "trust": 0.6,
            "value": "LOW"
          },
          {
            "author": "IVD",
            "id": "2d96ffb0-2353-11e6-abef-000c29c66e3d",
            "trust": 0.2,
            "value": "LOW"
          },
          {
            "author": "VULHUB",
            "id": "VHN-57972",
            "trust": 0.1,
            "value": "LOW"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "2d96ffb0-2353-11e6-abef-000c29c66e3d"
      },
      {
        "db": "VULHUB",
        "id": "VHN-57972"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-005759"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201212-250"
      },
      {
        "db": "NVD",
        "id": "CVE-2012-4691"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Memory leak in Siemens Automation License Manager (ALM) 4.x and 5.x before 5.2 allows remote attackers to cause a denial of service (memory consumption) via crafted packets. The Siemens Automation License Manager is the certificate management software used by various Siemens software products. The following products are affected by this vulnerability: SIMATIC (eg STEP 7) SIMATIC HMI (eg WinCC, WinCC flexible) SIMATIC PCS 7 SIMOTION (eg Scout) SIMATIC NET SINAMICS (eg Starter) SIMOCODE. \nSuccessful exploits will cause an affected application to cause a memory  leakage and terminate the application, denying service to legitimate  users",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2012-4691"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-005759"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-7524"
      },
      {
        "db": "BID",
        "id": "56954"
      },
      {
        "db": "IVD",
        "id": "2d96ffb0-2353-11e6-abef-000c29c66e3d"
      },
      {
        "db": "VULHUB",
        "id": "VHN-57972"
      }
    ],
    "trust": 2.7
  },
  "exploit_availability": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/exploit_availability#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "reference": "https://www.scap.org.cn/vuln/vhn-57972",
        "trust": 0.1,
        "type": "unknown"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-57972"
      }
    ]
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2012-4691",
        "trust": 3.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-12-349-01",
        "trust": 3.4
      },
      {
        "db": "SIEMENS",
        "id": "SSA-783261",
        "trust": 1.7
      },
      {
        "db": "BID",
        "id": "56954",
        "trust": 1.0
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201212-250",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-7524",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-005759",
        "trust": 0.8
      },
      {
        "db": "IVD",
        "id": "2D96FFB0-2353-11E6-ABEF-000C29C66E3D",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-57972",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "2d96ffb0-2353-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-7524"
      },
      {
        "db": "VULHUB",
        "id": "VHN-57972"
      },
      {
        "db": "BID",
        "id": "56954"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-005759"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201212-250"
      },
      {
        "db": "NVD",
        "id": "CVE-2012-4691"
      }
    ]
  },
  "id": "VAR-201212-0032",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "2d96ffb0-2353-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-7524"
      },
      {
        "db": "VULHUB",
        "id": "VHN-57972"
      }
    ],
    "trust": 1.6034409025
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "2d96ffb0-2353-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-7524"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:49:35.806000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "http://www.siemens.com/entry/cc/en/"
      },
      {
        "title": "SSA-783261: Denial-of-Service vulnerability in Siemens Automation License Manager (ALM)",
        "trust": 0.8,
        "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-783261.pdf"
      },
      {
        "title": "\u30b7\u30fc\u30e1\u30f3\u30b9\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u30d1\u30fc\u30c8\u30ca\u30fc",
        "trust": 0.8,
        "url": "http://www.automation.siemens.com/automation/jp/ja/solutionpartner/pages/default.aspx"
      },
      {
        "title": "\u30b7\u30fc\u30e1\u30f3\u30b9\u30fb\u30b8\u30e3\u30d1\u30f3\u682a\u5f0f\u4f1a\u793e",
        "trust": 0.8,
        "url": "http://www.siemens.com/answers/jp/ja/"
      },
      {
        "title": "Siemens Automation License Manager denial of service vulnerability patch",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/26615"
      },
      {
        "title": "ALMv5_2",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=45585"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2012-7524"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-005759"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201212-250"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-399",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-57972"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-005759"
      },
      {
        "db": "NVD",
        "id": "CVE-2012-4691"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.8,
        "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-349-01.pdf"
      },
      {
        "trust": 1.7,
        "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-783261.pdf"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2012-4691"
      },
      {
        "trust": 0.8,
        "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2012-4691"
      },
      {
        "trust": 0.6,
        "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-349-01.pdfhttp"
      },
      {
        "trust": 0.6,
        "url": "http://www.securityfocus.com/bid/56954"
      },
      {
        "trust": 0.3,
        "url": "http://support.automation.siemens.com/ww/llisapi.dll?func=cslib.csinfo\u0026lang=en\u0026siteid=cseus\u0026aktprim=0\u0026extranet=standard\u0026viewreg=ww\u0026objid=17323948\u0026tree"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2012-7524"
      },
      {
        "db": "VULHUB",
        "id": "VHN-57972"
      },
      {
        "db": "BID",
        "id": "56954"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-005759"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201212-250"
      },
      {
        "db": "NVD",
        "id": "CVE-2012-4691"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "2d96ffb0-2353-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-7524"
      },
      {
        "db": "VULHUB",
        "id": "VHN-57972"
      },
      {
        "db": "BID",
        "id": "56954"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-005759"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201212-250"
      },
      {
        "db": "NVD",
        "id": "CVE-2012-4691"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2012-12-19T00:00:00",
        "db": "IVD",
        "id": "2d96ffb0-2353-11e6-abef-000c29c66e3d"
      },
      {
        "date": "2012-12-19T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2012-7524"
      },
      {
        "date": "2012-12-18T00:00:00",
        "db": "VULHUB",
        "id": "VHN-57972"
      },
      {
        "date": "2012-12-14T00:00:00",
        "db": "BID",
        "id": "56954"
      },
      {
        "date": "2012-12-20T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2012-005759"
      },
      {
        "date": "2012-12-19T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201212-250"
      },
      {
        "date": "2012-12-18T12:30:05.810000",
        "db": "NVD",
        "id": "CVE-2012-4691"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2012-12-19T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2012-7524"
      },
      {
        "date": "2013-01-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-57972"
      },
      {
        "date": "2015-03-19T08:25:00",
        "db": "BID",
        "id": "56954"
      },
      {
        "date": "2012-12-20T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2012-005759"
      },
      {
        "date": "2012-12-19T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201212-250"
      },
      {
        "date": "2024-11-21T01:43:21.960000",
        "db": "NVD",
        "id": "CVE-2012-4691"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "specific network environment",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201212-250"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens Automation License Manager Denial of service vulnerability",
    "sources": [
      {
        "db": "IVD",
        "id": "2d96ffb0-2353-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-7524"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201212-250"
      }
    ],
    "trust": 1.4
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Resource management error",
    "sources": [
      {
        "db": "IVD",
        "id": "2d96ffb0-2353-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201212-250"
      }
    ],
    "trust": 0.8
  }
}

var-201712-0703
Vulnerability from variot

Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually. plural Siemens The product contains data processing vulnerabilities.Service operation interruption (DoS) There is a possibility of being put into a state. SiemensSIMATICS7-200Smart and others are products of Siemens AG. The Siemens SIMATICS7-200Smart is a programmable logic controller (PLC) for use in small and medium-sized automation systems. SIMATICWinACRTX2010incl is a software controller for automation solutions. A denial of service vulnerability exists in several Siemens products. Attackers can exploit this issue to crash the affected device, denying service to legitimate users. A vulnerability has been identified in SIMATIC S7-200 Smart (All versions < V2.03.01), SIMATIC S7-400 PN V6 (All versions < V6.0.6), SIMATIC S7-400 H V6 (All versions < V6.0.8), SIMATIC S7-400 PN/DP V7 (All versions < V7.0.2), SIMATIC S7-410 V8 (All versions < V8.2.1), SIMATIC S7-300 (All versions < V3.X.16), SIMATIC S7-1200 (All versions < V4.2.3), SIMATIC S7-1500 (All versions < V2.0), SIMATIC S7-1500 Software Controller (All versions < V2.0), SIMATIC WinAC RTX 2010 incl. F (All versions), SIMATIC ET 200AL (All versions), SIMATIC ET 200ecoPN (All versions), SIMATIC ET 200M (All versions), SIMATIC ET 200MP IM155-5 PN BA (All versions < V4.0.2), SIMATIC ET 200MP IM155-5 PN ST (All versions < V4.1), SIMATIC ET 200MP IM155-5 PN HF (All versions < V4.2), SIMATIC ET 200pro (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200SP IM155-6 PN HF (All versions < V4.2.0), SIMATIC ET 200SP IM155-6 PN HA (All versions < V1.1.0), SIMATIC ET 200SP IM155-6 PN BA (All versions), SIMATIC ET 200SP IM155-6 PN ST (All versions), SIMATIC ET 200SP IM155-6 PN HS (All versions), Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions < V4.1.1 Patch 05), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions < V4.5), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions < V4.5), SIMOTION D (All versions < V5.1 HF1), SIMOTION C (All versions < V5.1 HF1), SIMOTION P V4.4 and V4.5 (All versions < V4.5 HF5), SIMOTION P V5 (All versions < V5.1 HF1), SINAMICS DCM w. PN (All versions < V1.4 SP1 HF6), SINAMICS DCP w. PN (All versions < V1.2 HF2), SINAMICS G110M w. PN (All versions < V4.7 SP9 HF1), SINAMICS G120 (C/P/D) w. PN (All versions < V4.7 SP9 HF1), SINAMICS G130 V4.7 w. PN (All versions < V4.7 HF29), SINAMICS G130 V4.8 w. PN (All versions < V4.8 HF4), SINAMICS G150 V4.7 w. PN (All versions < V4.7 HF29), SINAMICS G150 V4.8 w. PN (All versions < V4.8 HF4), SINAMICS S110 w. PN (All versions < V4.4 SP3 HF6), SINAMICS S120 prior to V4.7 w. PN (All versions < V4.7), SINAMICS S120 V4.7 w. PN (All versions < V4.7 HF29), SINAMICS S120 V4.7 SP1 w. PN (All versions), SINAMICS S120 V4.8 w. PN (All versions < V4.8 HF5), SINAMICS S150 V4.7 w. PN (All versions < V4.7 HF29), SINAMICS S150 V4.8 w. PN (All versions < V4.8 HF4), SINAMICS V90 w. PN (All versions < V1.02), SINUMERIK 840D sl (All versions), SIMATIC Compact Field Unit (All versions), SIMATIC PN/PN Coupler (All versions < V4.2.0), SIMOCODE pro V PROFINET (All versions < V2.1.1), SIRIUS Soft Starter 3RW44 PN (All versions), SIMOCODE pro V EIP (All versions < V1.0.2). Siemens SIMATIC S7-1500 CPU, etc. SIMATIC S7-1500 CPU is a CPU (central processing unit) module. SIMATIC S7-1500 is a programmable logic controller. SINUMERIK 840D sl is a set of advanced machine tool numerical control system. The following products and versions are affected: Siemens SIMATIC S7-200 Smart prior to V2.03.01; SIMATIC S7-400 PN/DP V7 CPU family (SIPLUS variants); SIMATIC S7-410 V8 CPU family (SIPLUS variants); SIMATIC S7- 300 CPU family (related to ET200 CPUs and SIPLUS variants); SIMATIC S7-1200 CPU family (related to SIPLUS variants); SIMATIC S7-1500 CPU family (related to ET200 CPUs and SIPLUS variants); SIMATIC S7-1500 Software Controller prior to V2.0 wait

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201712-0703",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "sinamics s120",
        "scope": "eq",
        "trust": 1.9,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinumerik 840d sl",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic compact field unit",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic pn\\/pn coupler",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics v90pn",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s150 v4.8",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simocode pro v profinet",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s150 v4.7",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s110pn",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sirius soft starter 3rw44pn",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-300",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-1200",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-1500",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-1500 software controller",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200al",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200ecopn",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200m",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200mp",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200pro",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200s",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics dcm",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics dcp",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200sp",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "dk standard ethernet controller",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s120",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinumerik 840d sl",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic compact field unit",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic pn/pn coupler",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sirius soft starter 3rw44 pn",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g150",
        "scope": "eq",
        "trust": 1.3,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g130",
        "scope": "eq",
        "trust": 1.3,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-1200",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "dk standard ethernet controller",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g110m\\/g120pn",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "simatic s7-1500",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.0"
      },
      {
        "model": "simatic s7-300",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200sp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200s",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-1500 controller",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.0"
      },
      {
        "model": "simatic s7-400pn v6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.0.6"
      },
      {
        "model": "simatic winac rtx f 2010",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "ek-ertec 200pn io",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simotion c",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "simatic et 200mp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200ecopn",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200al",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics dcm",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-410 v8",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simotion p",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "simatic s7-400h v6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.0.8"
      },
      {
        "model": "simatic s7-400pn\\/dp v7",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-200",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.03.01"
      },
      {
        "model": "ek-ertec 200p",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "simatic et 200pro",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simotion d",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "sinamics dcp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "ek-ertec 200 pn io",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "ek-ertec 200p p",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-200 smart",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-400 pn v6",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-400 pn/dp v7",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-400h v6",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-410 v8",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic winac rtx 2010 incl. f",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simocode pro v profinet",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simotion c",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simotion d",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simotion p",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g110m",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g130",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g150",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s110 w. pn",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s150 v4.7 w. pn",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s150 v4.8 w. pn",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics v90 w. pn",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-200 smart",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v2.03.01"
      },
      {
        "model": "simatic s7-400 pn",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v6\u003cv6.0.6"
      },
      {
        "model": "simatic s7-400 h",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v6"
      },
      {
        "model": "simatic s7-400 pn/dp",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v7"
      },
      {
        "model": "simatic s7-410",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v8"
      },
      {
        "model": "simatic winac rtx incl.f",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "2010"
      },
      {
        "model": "ek-ertec pn io",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "200"
      },
      {
        "model": "simotion d hf1",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v5.1"
      },
      {
        "model": "simotion c hf1",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v5.1"
      },
      {
        "model": "simotion p hf1",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v5.1"
      },
      {
        "model": "sinamics g110m/g120 w.pn sp9 hf1",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v4.7"
      },
      {
        "model": "ek-ertec 200p",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v4.5"
      },
      {
        "model": "sinamics s110 w.pn",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s150",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v4.7"
      },
      {
        "model": "sinamics s150",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v4.8"
      },
      {
        "model": "sinamics w.pn",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v90"
      },
      {
        "model": "simocode pro profinet",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v"
      },
      {
        "model": "sinamics g130 and g150",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "softnet profinet io",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sirius soft starter 3rw44 pn",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sinumerik 840d sl",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinumerik 840d",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sinamics sm150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics sm120",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics sl150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7.5"
      },
      {
        "model": "sinamics sl150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7.4"
      },
      {
        "model": "sinamics sl150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics s150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s120",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sinamics gm150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics gl150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics gh150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics g120",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics dcp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sinamics dcm",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simotion",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simocode pro eip",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v1.0.1"
      },
      {
        "model": "simocode pro eip",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v1.0"
      },
      {
        "model": "simatic winac rtx",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "20100"
      },
      {
        "model": "simatic winac rtx f sp2",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2010"
      },
      {
        "model": "simatic winac rtx sp2",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2010"
      },
      {
        "model": "simatic s7-410",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "8"
      },
      {
        "model": "simatic s7-400 pn",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v60"
      },
      {
        "model": "simatic s7-400 pn",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic s7-400 h",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v60"
      },
      {
        "model": "simatic s7-300",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic s7-200",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic s7-1500",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1.8.3"
      },
      {
        "model": "simatic s7-1500",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1.6"
      },
      {
        "model": "simatic s7-1500",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1.5.0"
      },
      {
        "model": "simatic s7-1500",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic s7-1200",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.1.3"
      },
      {
        "model": "simatic s7-1200",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.0"
      },
      {
        "model": "simatic s7-1200",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "3.0.1"
      },
      {
        "model": "simatic s7-1200",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "3.0.0"
      },
      {
        "model": "simatic s7-1200",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "3.0"
      },
      {
        "model": "simatic s7-1200",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2.0.3"
      },
      {
        "model": "simatic s7-1200",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2.0.2"
      },
      {
        "model": "simatic et",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2000"
      },
      {
        "model": "simatic compact field unit",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "profinet io",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1.4.1"
      },
      {
        "model": "profinet io",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sinamics sm120 sp2",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics sl150 sp2",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics gm150 sp2",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics gl150 sp2",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics gh150 sp2",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics g120p",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g120d",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g120c",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g120 update sp9 hf1",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics g110m",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simotion p hf1",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "simotion c hf1",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "simocode pro eip",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v1.0.2"
      },
      {
        "model": "simatic s7-400 pn",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v66.0.6"
      },
      {
        "model": "simatic s7-200 smart",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2.3.1"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 200",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic winac rtx f 2010",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200al",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200ecopn",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200m",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200mp",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200pro",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200s",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200sp",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dk standard ethernet controller",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "ek ertec 200p",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 400pn v6",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "ek ertec 200pn io",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simotion d",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simotion c",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simotion p",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics dcm",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics dcp",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics g110m g120pn",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics g130",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics g150",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics s110pn",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 400h v6",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics s120",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics s150 v4 7",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics s150 v4 8",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics v90pn",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinumerik 840d sl",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic compact field unit",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic pn pn coupler",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simocode pro v profinet",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sirius soft starter 3rw44pn",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 400pn dp v7",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 410 v8",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 300",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1200",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1500",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1500 controller",
        "version": "2.0"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2df32de-39ab-11e9-b092-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-36884"
      },
      {
        "db": "BID",
        "id": "101964"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-011798"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-1105"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-12741"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:siemens:dk_standard_ethernet_controller_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:ek-ertec_200_pn_io_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:ek-ertec_200p_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_compact_field_unit_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_et_200al_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_et_200ecopn_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_et_200m_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_et_200mp_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_et_200pro_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_et_200s_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_et_200sp_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_pn%2Fpn_coupler_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_s7-1200_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_s7-1500_software_controller_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_s7-1500_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_s7-200_smart_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_s7-300_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_s7-400pn_v6_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_s7-400pn%2Fdp_v7_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_s7-400h_v6_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_s7-410_v8_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_winac_rtx_f_2010_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simocode_pro_v_profinet_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simotion_c_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simotion_d_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simotion_p_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sinamics_dcm_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sinamics_dcp_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sinamics_g110m_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sinamics_g130_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sinamics_g150_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sinamics__s110_w._pn_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sinamics_s120_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sinamics_s150_v4.7_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sinamics_s150_v4.8_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sinamics_v90_w._pn_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sinumerik_840d_sl_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sirius_soft_starter_3rw44_pn_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-011798"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens ProductCERT reported this vulnerability to NCCIC.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-1105"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2017-12741",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "[email protected]",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2017-12741",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2017-36884",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "e2df32de-39ab-11e9-b092-000c29342cb1",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-103294",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "[email protected]",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2017-12741",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "[email protected]",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2017-12741",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "[email protected]",
            "id": "CVE-2017-12741",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "[email protected]",
            "id": "CVE-2017-12741",
            "trust": 1.0,
            "value": "High"
          },
          {
            "author": "NVD",
            "id": "CVE-2017-12741",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2017-36884",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201711-1105",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "IVD",
            "id": "e2df32de-39ab-11e9-b092-000c29342cb1",
            "trust": 0.2,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-103294",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2df32de-39ab-11e9-b092-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-36884"
      },
      {
        "db": "VULHUB",
        "id": "VHN-103294"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-011798"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-1105"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-12741"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-12741"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually. plural Siemens The product contains data processing vulnerabilities.Service operation interruption (DoS) There is a possibility of being put into a state. SiemensSIMATICS7-200Smart and others are products of Siemens AG. The Siemens SIMATICS7-200Smart is a programmable logic controller (PLC) for use in small and medium-sized automation systems. SIMATICWinACRTX2010incl is a software controller for automation solutions. A denial of service vulnerability exists in several Siemens products. \nAttackers can exploit this issue to crash the affected device, denying service to legitimate users. A vulnerability has been identified in SIMATIC S7-200 Smart (All versions \u003c V2.03.01), SIMATIC S7-400 PN V6 (All versions \u003c V6.0.6), SIMATIC S7-400 H V6 (All versions \u003c V6.0.8), SIMATIC S7-400 PN/DP V7 (All versions \u003c V7.0.2), SIMATIC S7-410 V8 (All versions \u003c V8.2.1), SIMATIC S7-300 (All versions \u003c V3.X.16), SIMATIC S7-1200 (All versions \u003c V4.2.3), SIMATIC S7-1500 (All versions \u003c V2.0), SIMATIC S7-1500 Software Controller (All versions \u003c V2.0), SIMATIC WinAC RTX 2010 incl. F (All versions), SIMATIC ET 200AL (All versions), SIMATIC ET 200ecoPN (All versions), SIMATIC ET 200M (All versions), SIMATIC ET 200MP IM155-5 PN BA (All versions \u003c V4.0.2), SIMATIC ET 200MP IM155-5 PN ST (All versions \u003c V4.1), SIMATIC ET 200MP IM155-5 PN HF (All versions \u003c V4.2), SIMATIC ET 200pro (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200SP IM155-6 PN HF (All versions \u003c V4.2.0), SIMATIC ET 200SP IM155-6 PN HA (All versions \u003c V1.1.0), SIMATIC ET 200SP IM155-6 PN BA (All versions), SIMATIC ET 200SP IM155-6 PN ST (All versions), SIMATIC ET 200SP IM155-6 PN HS (All versions), Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions \u003c V4.1.1 Patch 05), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions \u003c V4.5), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions \u003c V4.5), SIMOTION D (All versions \u003c V5.1 HF1), SIMOTION C (All versions \u003c V5.1 HF1), SIMOTION P V4.4 and V4.5 (All versions \u003c V4.5 HF5), SIMOTION P V5 (All versions \u003c V5.1 HF1), SINAMICS DCM w. PN (All versions \u003c V1.4 SP1 HF6), SINAMICS DCP w. PN (All versions \u003c V1.2 HF2), SINAMICS G110M w. PN (All versions \u003c V4.7 SP9 HF1), SINAMICS G120 (C/P/D) w. PN (All versions \u003c V4.7 SP9 HF1), SINAMICS G130 V4.7 w. PN (All versions \u003c V4.7 HF29), SINAMICS G130 V4.8 w. PN (All versions \u003c V4.8 HF4), SINAMICS G150 V4.7 w. PN (All versions \u003c V4.7 HF29), SINAMICS G150 V4.8 w. PN (All versions \u003c V4.8 HF4), SINAMICS S110 w. PN (All versions \u003c V4.4 SP3 HF6), SINAMICS S120 prior to V4.7 w. PN (All versions \u003c V4.7), SINAMICS S120 V4.7 w. PN (All versions \u003c V4.7 HF29), SINAMICS S120 V4.7 SP1 w. PN (All versions), SINAMICS S120 V4.8 w. PN (All versions \u003c V4.8 HF5), SINAMICS S150 V4.7 w. PN (All versions \u003c V4.7 HF29), SINAMICS S150 V4.8 w. PN (All versions \u003c V4.8 HF4), SINAMICS V90 w. PN (All versions \u003c V1.02), SINUMERIK 840D sl (All versions), SIMATIC Compact Field Unit (All versions), SIMATIC PN/PN Coupler (All versions \u003c V4.2.0), SIMOCODE pro V PROFINET (All versions \u003c V2.1.1), SIRIUS Soft Starter 3RW44 PN (All versions), SIMOCODE pro V EIP (All versions \u003c V1.0.2). Siemens SIMATIC S7-1500 CPU, etc. SIMATIC S7-1500 CPU is a CPU (central processing unit) module. SIMATIC S7-1500 is a programmable logic controller. SINUMERIK 840D sl is a set of advanced machine tool numerical control system. The following products and versions are affected: Siemens SIMATIC S7-200 Smart prior to V2.03.01; SIMATIC S7-400 PN/DP V7 CPU family (SIPLUS variants); SIMATIC S7-410 V8 CPU family (SIPLUS variants); SIMATIC S7- 300 CPU family (related to ET200 CPUs and SIPLUS variants); SIMATIC S7-1200 CPU family (related to SIPLUS variants); SIMATIC S7-1500 CPU family (related to ET200 CPUs and SIPLUS variants); SIMATIC S7-1500 Software Controller prior to V2.0 wait",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2017-12741"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-011798"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-36884"
      },
      {
        "db": "BID",
        "id": "101964"
      },
      {
        "db": "IVD",
        "id": "e2df32de-39ab-11e9-b092-000c29342cb1"
      },
      {
        "db": "VULHUB",
        "id": "VHN-103294"
      }
    ],
    "trust": 2.7
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2017-12741",
        "trust": 3.6
      },
      {
        "db": "BID",
        "id": "101964",
        "trust": 2.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-17-339-01",
        "trust": 2.3
      },
      {
        "db": "SIEMENS",
        "id": "SSA-346262",
        "trust": 2.0
      },
      {
        "db": "SIEMENS",
        "id": "SSA-546832",
        "trust": 2.0
      },
      {
        "db": "SIEMENS",
        "id": "SSA-141614",
        "trust": 1.7
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-18-128-01",
        "trust": 1.7
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-19-099-01",
        "trust": 1.7
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-1105",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-36884",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-011798",
        "trust": 0.8
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2019.1206",
        "trust": 0.6
      },
      {
        "db": "IVD",
        "id": "E2DF32DE-39AB-11E9-B092-000C29342CB1",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-103294",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2df32de-39ab-11e9-b092-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-36884"
      },
      {
        "db": "VULHUB",
        "id": "VHN-103294"
      },
      {
        "db": "BID",
        "id": "101964"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-011798"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-1105"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-12741"
      }
    ]
  },
  "id": "VAR-201712-0703",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "e2df32de-39ab-11e9-b092-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-36884"
      },
      {
        "db": "VULHUB",
        "id": "VHN-103294"
      }
    ],
    "trust": 1.560734225135135
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS",
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      },
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.2
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2df32de-39ab-11e9-b092-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-36884"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:56:02.420000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-346262",
        "trust": 0.8,
        "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-346262.pdf"
      },
      {
        "title": "Patches for multiple Siemens product denial of service vulnerabilities",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/109849"
      },
      {
        "title": "Multiple Siemens Product security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=76771"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-36884"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-011798"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-1105"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-400",
        "trust": 1.0
      },
      {
        "problemtype": "NVD-CWE-noinfo",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-19",
        "trust": 0.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-103294"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-011798"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-12741"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.9,
        "url": "https://www.securityfocus.com/bid/101964"
      },
      {
        "trust": 2.3,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-17-339-01"
      },
      {
        "trust": 1.7,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-141614.pdf"
      },
      {
        "trust": 1.7,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-346262.pdf"
      },
      {
        "trust": 1.7,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf"
      },
      {
        "trust": 1.7,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-128-01"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-346262.html"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-141614.html"
      },
      {
        "trust": 0.9,
        "url": "http://www.siemens.com/"
      },
      {
        "trust": 0.9,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-19-099-01"
      },
      {
        "trust": 0.9,
        "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-346262.pdf"
      },
      {
        "trust": 0.9,
        "url": "https://cert-portal.siemens.com/productcert/txt/ssa-546832.txt"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-12741"
      },
      {
        "trust": 0.8,
        "url": "https://www.us-cert.gov/ics/advisories/icsa-19-099-01"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-12741"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/78750"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-17-339-01"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-36884"
      },
      {
        "db": "VULHUB",
        "id": "VHN-103294"
      },
      {
        "db": "BID",
        "id": "101964"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-011798"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-1105"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-12741"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "e2df32de-39ab-11e9-b092-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-36884"
      },
      {
        "db": "VULHUB",
        "id": "VHN-103294"
      },
      {
        "db": "BID",
        "id": "101964"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-011798"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-1105"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-12741"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-12-12T00:00:00",
        "db": "IVD",
        "id": "e2df32de-39ab-11e9-b092-000c29342cb1"
      },
      {
        "date": "2017-12-12T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2017-36884"
      },
      {
        "date": "2017-12-26T00:00:00",
        "db": "VULHUB",
        "id": "VHN-103294"
      },
      {
        "date": "2017-11-23T00:00:00",
        "db": "BID",
        "id": "101964"
      },
      {
        "date": "2018-01-26T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-011798"
      },
      {
        "date": "2017-11-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201711-1105"
      },
      {
        "date": "2017-12-26T04:29:13.707000",
        "db": "NVD",
        "id": "CVE-2017-12741"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-12-12T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2017-36884"
      },
      {
        "date": "2020-08-14T00:00:00",
        "db": "VULHUB",
        "id": "VHN-103294"
      },
      {
        "date": "2019-04-10T07:00:00",
        "db": "BID",
        "id": "101964"
      },
      {
        "date": "2019-07-08T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-011798"
      },
      {
        "date": "2022-02-11T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201711-1105"
      },
      {
        "date": "2024-11-21T03:10:07.963000",
        "db": "NVD",
        "id": "CVE-2017-12741"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-1105"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Siemens Data processing vulnerabilities in products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-011798"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "resource management error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-1105"
      }
    ],
    "trust": 0.6
  }
}

var-201705-3220
Vulnerability from variot

Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected. SIMATIC CP, SIMATIC RF600, SCALANCE W700, etc. are all industrial automation products from Siemens AG. A denial of service vulnerability exists in several industrial devices from Siemens. Multiple Siemens Products is prone to multiple denial-of-service vulnerabilities. Attackers can exploit these issues to cause a denial-of-service condition. Manual restart of the server is required to resume normal operation. SIEMENS SIMATIC CP 343-1 Std, CP 343-1 Lean (All versions), SIMATIC CP 343-1 Adv (All versions), SIMATIC CP 443-1 Std, CP 443-1 Adv (All versions before V3.2.17), SIMATIC CP 443-1 OPC-UA (All versions), SIMATIC CP 1243-1 (All versions before V2.1.82), SIMATIC CP 1243-1 IRC (All versions before V2.1.82), SIMATIC CP 1243-1 IEC (All versions), SIMATIC CP 1243-1 DNP3 (All versions), SIMATIC CM 1542-1 (All versions before V2.0), SIMATIC CP 1542SP-1, CP 1542SP-1 IRC, and CP 1543SP-1 (All versions before to V1.0.15), SIMATIC CP 1543-1 (All versions before V2.1), SIMATIC RF650R, RF680R, RF685R (All versions before V3.0), SIMATIC CP 1616, CP 1604, DK-16xx PN IO (All versions before V2.7), SCALANCE X-200 (All versions before V5.2.2), SCALANCE X200 IRT (All versions before V5.4.0), SCALANCE X-300/X408 (All versions before V4.1.0), SCALANCE X414 (All versions before V3.10.2), SCALANCE XM400, XR500 (All versions before V6.1), SCALANCE W700 (All versions before V6.1), SCALANCE M-800, S615 (All versions before V04.03), Softnet PROFINET IO for PC-based Windows systems (All versions before V14 SP1), IE/PB-Link (All versions before V3.0), IE/AS-i Link PN IO (All versions), SIMATIC Teleservice Adapter Standard Modem, IE Basic, IE Advanced (All versions), SITOP PSU8600 PROFINET (All versions before V1.2.0), SITOP UPS1600 PROFINET (All versions before V2.2.0), SIMATIC ET 200AL (All versions before V1.0.2), SIMATIC ET 200ecoPN (All versions), SIMATIC ET 200M (All versions), SIMATIC ET 200MP (All versions before V4.0.1), SIMATIC ET 200pro (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200SP (All versions before V4.1.0), SIMATIC PN/PN Coupler (All versions before V4.0), DK Standard Ethernet Controller (All versions before V4.1.1 Patch04), EK-ERTEC 200P PN IO (All versions before V4.4.0 Patch01), EK-ERTEC 200 PN IO (All versions before V4.2.1 Patch03), SIMATIC S7-200 SMART (All versions before V2.3), SIMATIC S7-300 incl. F and T (All versions before V3.X.14), SIMATIC S7-400 PN/DP V6 Incl. F (All versions before V6.0.6), SIMATIC S7-400-H V6 (All versions before V6.0.7), SIMATIC S7-400 PN/DP V7 incl. F (All versions), SIMATIC S7-CPU 410 (All versions before V8.2), SIMATIC S7-1200 incl. F (All versions before V4.2.1), SIMATIC S7-1500 incl. F, T, and TF (All versions before V2.1), SIMATIC S7-1500 Software Controller incl. F (All versions before V2.1), SIMATIC WinAC RTX 2010 incl. F (All versions), SIRIUS ACT 3SU1 interface module PROFINET (All versions), SIRIUS Soft starter 3RW44 PN (All versions), SIRIUS Motor starter M200D PROFINET (All versions), SIMOCODE pro V PROFINET (All versions), SINAMICS DCM (All versions before V1.4 SP1 HF5), SINAMICS DCP (All versions), SINAMICS G110M / G120(C/P/D) w. PN (All versions before V4.7 SP6 HF3), SINAMICS G130 and G150 (All versions before V4.7 HF27 and V4.8 before HF4), SINAMICS S110 w. PN (All versions before V4.4 SP1 HF5), SINAMICS S120 (All versions before V4.7 HF27 and V4.8 before HF4), SINAMICS S150 (All versions before V4.7 HF27 and V4.8 before HF4), SINAMICS V90 w. PN (All versions before V1.1), SIMOTION (All versions before V4.5 HF1), SINUMERIK 828D (All versions before V4.5 SP6 HF2 and V4.7 before SP6 HF8), SINUMERIK 840D sl (All versions before V4.5 SP6 HF8 and V4.7 before SP4 HF1), SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (All versions) could be affected by a Denial-of-Service condition induced by a specially crafted PROFINET DCP broadcast (Layer 2 - Ethernet) packet. Siemens SIMATIC S7-200 Smart, etc. Siemens SIMATIC S7-200 Smart is a programmable logic controller (PLC) used in small and medium-sized automation systems. Siemens SIMATIC CP 343-1 Advanced is an Ethernet communication module used to support PROFINET (a new generation of automation bus standard based on industrial Ethernet technology). SIRIUS Motor starter M200D PROFINET is a motor starter. The following products and versions are affected: Siemens Extension Unit 12\" PROFINET prior to V01.01.01; Extension Unit 15\" PROFINET prior to V01.01.01; Extension Unit 19\" PROFINET prior to V01.01.01; Extension Unit 22\" PROFINET SIMATIC CP 1242-7 GPRS V2 prior to V2.1.82; SIMATIC CP 1243-7 LTE/US prior to V2.1.82; SIMATIC CP 1243-8 prior to V2.1.82; SIMATIC CP 1626 V1.1 previous version

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201705-3220",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "simatic dk-16xx pn io",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic rf685r",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic rf650r",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic rf680r",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1543sp-1",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1542sp-1 irc",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1542sp-1",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xr500",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance s615",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance m-800",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xm400",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w700",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics gm150",
        "scope": "eq",
        "trust": 1.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics gh150",
        "scope": "eq",
        "trust": 1.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "simatic cp 1543-1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.1"
      },
      {
        "model": "sinamics s110 pn",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.4"
      },
      {
        "model": "simatic rf650r",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.0"
      },
      {
        "model": "dk standard ethernet controller",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.1"
      },
      {
        "model": "simatic cp 1626",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.1"
      },
      {
        "model": "scalance x414",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.10.2"
      },
      {
        "model": "scalance x200 irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.4.0"
      },
      {
        "model": "simatic cp 1243-1 dnp3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic cp 1242-7 gprs",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.1.82"
      },
      {
        "model": "sinamics gl150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics gm150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "simatic cp 1616",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.7"
      },
      {
        "model": "sinamics g150",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics g130",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics s120",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "simatic cp 1604",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.7"
      },
      {
        "model": "simatic s7-1200",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.2.1"
      },
      {
        "model": "extension unit 22 profinet",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "01.01.01"
      },
      {
        "model": "ek-ertec 200p pn io",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.4.0"
      },
      {
        "model": "ie\\/pb-link",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.0"
      },
      {
        "model": "simatic cm 1542-1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.0"
      },
      {
        "model": "sirius motor starter m200d profinet",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic rf680r",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.0"
      },
      {
        "model": "sinamics s110 pn",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.4"
      },
      {
        "model": "extension unit 19 profinet",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "01.01.01"
      },
      {
        "model": "simatic cp 1243-1 irc",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.1.82"
      },
      {
        "model": "sinamics dcp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.2"
      },
      {
        "model": "simatic cp 1542sp-1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.0.15"
      },
      {
        "model": "simatic cp 343-1 adv",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simotion",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "simatic teleservice adapter ie standard",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic cp 443-1 opc-ua",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic et 200s",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "dk standard ethernet controller",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.1"
      },
      {
        "model": "sinumerik 840d sl",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "simatic tdc cpu555",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.1.1"
      },
      {
        "model": "simatic et 200al",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.0.2"
      },
      {
        "model": "sinamics g150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics g110m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics gh150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "simatic cp 1543sp-1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.0.15"
      },
      {
        "model": "scalance xr500",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.1"
      },
      {
        "model": "simatic et 200ecopn",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "ek-ertec 200 pn io",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.2.1"
      },
      {
        "model": "softnet profinet io",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "14"
      },
      {
        "model": "scalance m-800",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.03"
      },
      {
        "model": "simatic hmi multi panels",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "scalance s615",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.03"
      },
      {
        "model": "simatic cp 443-1 adv",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.2.17"
      },
      {
        "model": "sinamics sl150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics dcp",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.2"
      },
      {
        "model": "simotion",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "sitop psu8600",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.2.0"
      },
      {
        "model": "sinumerik 840d sl",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "simatic hmi mobile panels",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "scalance x200",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.2"
      },
      {
        "model": "simatic s7-1500",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.1"
      },
      {
        "model": "simatic cp 343-1 std",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.1.3"
      },
      {
        "model": "simatic cp 1243-1 iec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic et 200pro",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "sinamics g110m",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "scalance xm400",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.1"
      },
      {
        "model": "sinamics sm120",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "scalance x408",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.0"
      },
      {
        "model": "simatic cp 343-1 lean",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.1.3"
      },
      {
        "model": "simatic dk-1604 pn io",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.7"
      },
      {
        "model": "sirius act 3su1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.1.0"
      },
      {
        "model": "ek-ertec 200 pn io",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.2.1"
      },
      {
        "model": "simatic s7-300",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "softnet profinet io",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "14"
      },
      {
        "model": "simatic tdc cp51m1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.1.8"
      },
      {
        "model": "simatic dk-1616 pn io",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.7"
      },
      {
        "model": "simatic et 200mp",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.0.1"
      },
      {
        "model": "sinamics dcm",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.4"
      },
      {
        "model": "sinamics sl150",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simatic s7-200 smart",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3"
      },
      {
        "model": "sinamics sm120",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "scalance w700",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.1"
      },
      {
        "model": "simatic et 200m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "extension unit 12 profinet",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "01.01.01"
      },
      {
        "model": "simatic winac rtx",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2010"
      },
      {
        "model": "extension unit 15 profinet",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "01.01.01"
      },
      {
        "model": "simatic s7-1500 software controller",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.1"
      },
      {
        "model": "sinamics g120\\ w. pn",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics s150",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "simatic cp 1542sp-1 irc",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.0.15"
      },
      {
        "model": "simatic cp 443-1 std",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.2.17"
      },
      {
        "model": "sinumerik 828d",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "simatic s7-400",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.0.6"
      },
      {
        "model": "simatic et 200sp",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.0"
      },
      {
        "model": "sirius soft starter 3rw44 pn",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic teleservice adapter ie basic",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simocode pro v profinet",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.0.0"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "ups1600 profinet",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.2.0"
      },
      {
        "model": "sinamics dcm",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.4"
      },
      {
        "model": "simatic cp 1243-1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.1.82"
      },
      {
        "model": "ie\\/as-i link pn io",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "sinamics gl150",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simatic cp 1243-8",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.1.82"
      },
      {
        "model": "sinamics v90 pn",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.01"
      },
      {
        "model": "scalance x300",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.0"
      },
      {
        "model": "simatic winac rtx",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2010"
      },
      {
        "model": "sinamics g130",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics s120",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "simatic rf685r",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.0"
      },
      {
        "model": "ek-ertec 200p pn io",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.4.0"
      },
      {
        "model": "sinamics s150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics g120\\ w. pn",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "simatic cp 1243-7 lte\\/us",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.1.82"
      },
      {
        "model": "pn\\/pn coupler",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.0"
      },
      {
        "model": "sinumerik 828d",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "simatic teleservice adapter ie advanced",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "dk standard ethernet controller",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "ek-ertec 200 pn io",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "ek-ertec 200p pn io",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "ie/as-i link pn io",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "ie/pb-link",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "pn/pn coupler",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance x200 irt",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance x200",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance x300",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance x408",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance x414",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cm 1542-1",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1243-1",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1543-1",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1604",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1616",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 343-1 adv",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 343-1 lean",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 343-1 std",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 443-1 adv",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 443-1 opc-ua",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 443-1 std",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200al",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200ecopn",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200m",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200mp",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200pro",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200s",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200sp",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi mobile panels",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi multi panels",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-1200",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-1500 software controller",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-1500",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-200 smart",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-300",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-400",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic teleservice adapter ie advanced",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic teleservice adapter ie basic",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic teleservice adapter standard modem",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic winac rtx 2010",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simocode pro v profinet",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simotion",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics dcm",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics dcp",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g110m",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g120 w. pn",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g130",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g150",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s110 w. pn",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s120",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s150",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics v90 w. pn",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinumerik 828d",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinumerik 840d sl",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sirius act 3su1 interface module profinet",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sirius motor starter m200d profinet",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sirius soft starter 3rw44 pn",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sitop psu8600",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sitop ups1600 profinet",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "softnet profinet io",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "for pc-based windows systems firmware"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "1616"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "1604"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "1543-1"
      },
      {
        "model": "simatic cm",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "1542-1"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "1243-1"
      },
      {
        "model": "simatic cp opc-ua",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "443-1"
      },
      {
        "model": "simatic cp adv",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "443-1"
      },
      {
        "model": "simatic cp std",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "443-1"
      },
      {
        "model": "simatic cp std",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "343-1"
      },
      {
        "model": "simatic cp lean",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "343-1"
      },
      {
        "model": "simatic cp adv",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "343-1"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x408"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x414"
      },
      {
        "model": "scalance irt",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x200"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x200"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x300"
      },
      {
        "model": "simatic rf650r",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 443-1 opc-ua",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cm 1542-1",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1542sp-1 irc",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 443-1 adv",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 343-1 std",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1543-1",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1543sp-1",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1542sp-1",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic rf680r",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.4,
        "vendor": "sinumerik 828d",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.4,
        "vendor": "sinumerik 840d sl",
        "version": "*"
      },
      {
        "model": "ups1600 profinet",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "softnet profinet io",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sitop psu8600",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sirius soft starter 3rw44 pn",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sirius act 3su1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sinumerik 840d",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sinumerik 828d",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sinamics sm150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics sm120",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics sl150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7.5"
      },
      {
        "model": "sinamics sl150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7.4"
      },
      {
        "model": "sinamics sl150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics gl150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simotion",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic winac rtx",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "20100"
      },
      {
        "model": "simatic teleservice adapter standard modem",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic s7-400",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic s7-300",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic s7-200 smart",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic s7-1500",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic rf685r",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic rf680r",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic rf650r",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic et",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2000"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "443-10"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "343-10"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "16260"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "16160"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "16040"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1543-12.0.28"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1543-10"
      },
      {
        "model": "simatic cp 1542sp-1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic cp irc",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1243-80"
      },
      {
        "model": "simatic cp lte eu/us",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1243-70"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1243-10"
      },
      {
        "model": "simatic cp gprs",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1242-7v20"
      },
      {
        "model": "scalance xr500",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "scalance xm400",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "x4140"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "x4084.0"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "x4083.0"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "x3000"
      },
      {
        "model": "scalance irt",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "x2000"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "x2000"
      },
      {
        "model": "scalance w700 series",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.4"
      },
      {
        "model": "scalance w700 series",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.5.4"
      },
      {
        "model": "scalance s615",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "scalance m-800",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.02"
      },
      {
        "model": "scalance m-800",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "ie/as-i link pn io",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "extension unit profinet",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "22?0"
      },
      {
        "model": "extension unit profinet",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "19?0"
      },
      {
        "model": "extension unit profinet",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15?0"
      },
      {
        "model": "extension unit profinet",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "12?0"
      },
      {
        "model": "e/pb-link",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sinumerik 840d sl",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinumerik 828d",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics sm120 sp2",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics sl150 sp2",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics gm150 sp2",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics gl150 sp2",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics gh150 sp2",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simatic rf685r",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "3.0"
      },
      {
        "model": "simatic rf680r",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "3.0"
      },
      {
        "model": "simatic cp",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "16162.7"
      },
      {
        "model": "simatic cp 1604d",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2.7"
      },
      {
        "model": "simatic cp irc",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1243-82.1.82"
      },
      {
        "model": "simatic cp lte eu/us",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1243-72.1.82"
      },
      {
        "model": "simatic cp gprs",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1242-7v22.1.82"
      },
      {
        "model": "simatic rf650r",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "3.0"
      },
      {
        "model": "simatic cp",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "443-13.2.17"
      },
      {
        "model": "simatic cp",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15431.2.1"
      },
      {
        "model": "simatic cm1542",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1.2"
      },
      {
        "model": "scalance w700",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "6.1"
      },
      {
        "model": "extension unit profinet",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "22?1.1.1"
      },
      {
        "model": "extension unit profinet",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "19?1.1.1"
      },
      {
        "model": "extension unit profinet",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15?1.1.1"
      },
      {
        "model": "extension unit profinet",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "12?1.1.1"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 343 1 std",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 1542sp 1 irc",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 1543sp 1",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 1543 1",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic rf650r",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic rf680r",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic rf685r",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 1616",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 1604",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic dk 16xx pn io",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance x200",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 343 1 lean",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance x200 irt",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance x300",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance x408",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance x414",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance xm400",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance xr500",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance w700",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance m 800",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance s615",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "softnet profinet io",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 343 1 adv",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "ie pb link",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "ie as i link pn io",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic teleservice adapter standard modem",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic teleservice adapter ie basic modem",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic teleservice adapter ie advanced modem",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sitop psu8600",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "ups1600 profinet",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200al",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200ecopn",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200m",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 443 1 std",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200mp",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200pro",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200s",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200sp",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "pn pn coupler",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dk standard ethernet controller",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "ek ertec 200p pn io",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "ek ertec 200 pn io",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 200 smart",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 300",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 443 1 adv",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 400",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1200",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1500",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1500 controller",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic winac rtx 2010",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sirius act 3su1",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sirius soft starter 3rw44 pn",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sirius motor starter m200d profinet",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simocode pro v profinet",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics dcm",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 443 1 opc ua",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics dcp",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics g110m",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics g120 c p d w pn",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics g130",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics g150",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics s110 w pn",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics s120",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics s150",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics v90 w pn",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simotion",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 1243 1",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi comfort panels",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi multi panels",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi mobile panels",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cm 1542 1",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 1542sp 1",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06151"
      },
      {
        "db": "BID",
        "id": "98369"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004134"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-574"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-2680"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:siemens:dk_standard_ethernet_controller_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:ek-ertec_200_pn_io_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:ek-ertec_200p_pn_io_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:ie%2Fpb-link_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:ie%2Fas-i_link_pn_io_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:pn%2Fpn_coupler_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:scalance_m-800_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:scalance_s615_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:scalance_w700_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:scalance_x200irt_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:scalance_x200_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:scalance_x300_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:scalance_x408_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:scalance_x414_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:scalance_xm400_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:scalance_xr500_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cm_1542-1_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cp_1243-1_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cp_1542sp-1_irc_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cp_1542sp-1_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cp_1543-1_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cp_1543sp-1_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cp_1604_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cp_1616_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cp_343-1_lean_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cp_343-1_adv_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cp_343-1_std_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cp_443-1_adv_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cp_443-1_std_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cp_443-1_opc-ua_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_dk-16xx_pn_io_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_et_200al_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_et_200ecopn_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_et_200m_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_et_200mp_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_et_200pro_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_et_200s_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_et_200sp_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_panels",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_mobile_panels",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_multi_panels",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_rf650r_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_rf680r_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_rf685r_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_s7-1200_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_s7-1500_software_controller_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_s7-1500_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_s7-200_smart_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_s7-300_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_s7-400_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_teleservice_adapter_ie_advanced_modem_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_teleservice_adapter_ie_basic_modem_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_teleservice_adapter_standard_modem_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_winac_rtx_2010_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simocode_pro_v_profinet_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simotion_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sinamics_dcm_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sinamics_dcp_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sinamics_g110m_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sinamics_g120%28c%2Fp%2Fd%29_w._pn_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sinamics_g130_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sinamics_g150_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sinamics__s110_w._pn_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sinamics_s120_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sinamics_s150_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sinamics_v90_w._pn_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sinumerik_828d_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sinumerik_840d_sl_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sirius_act_3su1_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sirius_motor_starter_m200d_profinet_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sirius_soft_starter_3rw44_pn_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sitop_psu8600_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:ups1600_profinet_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:softnet_profinet_io_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004134"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Duan JinTong, Ma ShaoShuai, and Cheng Lei from NSFOCUS Security Team.",
    "sources": [
      {
        "db": "BID",
        "id": "98369"
      }
    ],
    "trust": 0.3
  },
  "cve": "CVE-2017-2680",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "[email protected]",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.1,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "id": "CVE-2017-2680",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.1,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "id": "CNVD-2017-06151",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.1,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.2,
            "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.1,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "id": "VHN-110883",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:A/AC:L/AU:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "author": "[email protected]",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.8,
            "id": "CVE-2017-2680",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 2.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Adjacent Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 6.5,
            "baseSeverity": "Medium",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2017-2680",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "[email protected]",
            "id": "CVE-2017-2680",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "[email protected]",
            "id": "CVE-2017-2680",
            "trust": 1.0,
            "value": "High"
          },
          {
            "author": "NVD",
            "id": "CVE-2017-2680",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2017-06151",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201705-574",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "IVD",
            "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4",
            "trust": 0.2,
            "value": "MEDIUM"
          },
          {
            "author": "VULHUB",
            "id": "VHN-110883",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06151"
      },
      {
        "db": "VULHUB",
        "id": "VHN-110883"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004134"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-574"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-2680"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-2680"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected. SIMATIC CP, SIMATIC RF600, SCALANCE W700, etc. are all industrial automation products from Siemens AG. A denial of service vulnerability exists in several industrial devices from Siemens. Multiple Siemens Products is prone to multiple denial-of-service vulnerabilities. \nAttackers can exploit these issues to cause a denial-of-service condition. Manual restart of the server is required to resume normal operation. SIEMENS SIMATIC CP 343-1 Std, CP 343-1 Lean (All versions), SIMATIC CP 343-1 Adv (All versions), SIMATIC CP 443-1 Std, CP 443-1 Adv (All versions before V3.2.17), SIMATIC CP 443-1 OPC-UA (All versions), SIMATIC CP 1243-1 (All versions before V2.1.82), SIMATIC CP 1243-1 IRC (All versions before V2.1.82), SIMATIC CP 1243-1 IEC (All versions), SIMATIC CP 1243-1 DNP3 (All versions), SIMATIC CM 1542-1 (All versions before V2.0), SIMATIC CP 1542SP-1, CP 1542SP-1 IRC, and CP 1543SP-1 (All versions before to V1.0.15), SIMATIC CP 1543-1 (All versions before V2.1), SIMATIC RF650R, RF680R, RF685R (All versions before V3.0), SIMATIC CP 1616, CP 1604, DK-16xx PN IO (All versions before V2.7), SCALANCE X-200 (All versions before V5.2.2), SCALANCE X200 IRT (All versions before V5.4.0), SCALANCE X-300/X408 (All versions before V4.1.0), SCALANCE X414 (All versions before V3.10.2), SCALANCE XM400, XR500 (All versions before V6.1), SCALANCE W700 (All versions before V6.1), SCALANCE M-800, S615 (All versions before V04.03), Softnet PROFINET IO for PC-based Windows systems (All versions before V14 SP1), IE/PB-Link (All versions before V3.0), IE/AS-i Link PN IO (All versions), SIMATIC Teleservice Adapter Standard Modem, IE Basic, IE Advanced (All versions), SITOP PSU8600 PROFINET (All versions before V1.2.0), SITOP UPS1600 PROFINET (All versions before V2.2.0), SIMATIC ET 200AL (All versions before V1.0.2), SIMATIC ET 200ecoPN (All versions), SIMATIC ET 200M (All versions), SIMATIC ET 200MP (All versions before V4.0.1), SIMATIC ET 200pro (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200SP (All versions before V4.1.0), SIMATIC PN/PN Coupler (All versions before V4.0), DK Standard Ethernet Controller (All versions before V4.1.1 Patch04), EK-ERTEC 200P PN IO (All versions before V4.4.0 Patch01), EK-ERTEC 200 PN IO (All versions before V4.2.1 Patch03), SIMATIC S7-200 SMART (All versions before V2.3), SIMATIC S7-300 incl. F and T (All versions before V3.X.14), SIMATIC S7-400 PN/DP V6 Incl. F (All versions before V6.0.6), SIMATIC S7-400-H V6 (All versions before V6.0.7), SIMATIC S7-400 PN/DP V7 incl. F (All versions), SIMATIC S7-CPU 410 (All versions before V8.2), SIMATIC S7-1200 incl. F (All versions before V4.2.1), SIMATIC S7-1500 incl. F, T, and TF (All versions before V2.1), SIMATIC S7-1500 Software Controller incl. F (All versions before V2.1), SIMATIC WinAC RTX 2010 incl. F (All versions), SIRIUS ACT 3SU1 interface module PROFINET (All versions), SIRIUS Soft starter 3RW44 PN (All versions), SIRIUS Motor starter M200D PROFINET (All versions), SIMOCODE pro V PROFINET (All versions), SINAMICS DCM (All versions before V1.4 SP1 HF5), SINAMICS DCP (All versions), SINAMICS G110M / G120(C/P/D) w. PN (All versions before V4.7 SP6 HF3), SINAMICS G130 and G150 (All versions before V4.7 HF27 and V4.8 before HF4), SINAMICS S110 w. PN (All versions before V4.4 SP1 HF5), SINAMICS S120 (All versions before V4.7 HF27 and V4.8 before HF4), SINAMICS S150 (All versions before V4.7 HF27 and V4.8 before HF4), SINAMICS V90 w. PN (All versions before V1.1), SIMOTION (All versions before V4.5 HF1), SINUMERIK 828D (All versions before V4.5 SP6 HF2 and V4.7 before SP6 HF8), SINUMERIK 840D sl (All versions before V4.5 SP6 HF8 and V4.7 before SP4 HF1), SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (All versions) could be affected by a Denial-of-Service condition induced by a specially crafted PROFINET DCP broadcast (Layer 2 - Ethernet) packet. Siemens SIMATIC S7-200 Smart, etc. Siemens SIMATIC S7-200 Smart is a programmable logic controller (PLC) used in small and medium-sized automation systems. Siemens SIMATIC CP 343-1 Advanced is an Ethernet communication module used to support PROFINET (a new generation of automation bus standard based on industrial Ethernet technology). SIRIUS Motor starter M200D PROFINET is a motor starter. The following products and versions are affected: Siemens Extension Unit 12\\\" PROFINET prior to V01.01.01; Extension Unit 15\\\" PROFINET prior to V01.01.01; Extension Unit 19\\\" PROFINET prior to V01.01.01; Extension Unit 22\\\" PROFINET SIMATIC CP 1242-7 GPRS V2 prior to V2.1.82; SIMATIC CP 1243-7 LTE/US prior to V2.1.82; SIMATIC CP 1243-8 prior to V2.1.82; SIMATIC CP 1626 V1.1 previous version",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2017-2680"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004134"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06151"
      },
      {
        "db": "BID",
        "id": "98369"
      },
      {
        "db": "IVD",
        "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4"
      },
      {
        "db": "VULHUB",
        "id": "VHN-110883"
      }
    ],
    "trust": 2.7
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2017-2680",
        "trust": 3.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-18-023-02",
        "trust": 2.8
      },
      {
        "db": "SIEMENS",
        "id": "SSA-293562",
        "trust": 2.6
      },
      {
        "db": "SIEMENS",
        "id": "SSA-284673",
        "trust": 2.0
      },
      {
        "db": "BID",
        "id": "98369",
        "trust": 2.0
      },
      {
        "db": "SIEMENS",
        "id": "SSA-546832",
        "trust": 1.7
      },
      {
        "db": "SECTRACK",
        "id": "1038463",
        "trust": 1.7
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-17-129-02",
        "trust": 1.7
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-574",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06151",
        "trust": 0.8
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-18-128-01",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004134",
        "trust": 0.8
      },
      {
        "db": "IVD",
        "id": "296C9514-B30D-4FA5-BCDC-9D8B2E9620C4",
        "trust": 0.2
      },
      {
        "db": "SEEBUG",
        "id": "SSVID-99023",
        "trust": 0.1
      },
      {
        "db": "VULHUB",
        "id": "VHN-110883",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06151"
      },
      {
        "db": "VULHUB",
        "id": "VHN-110883"
      },
      {
        "db": "BID",
        "id": "98369"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004134"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-574"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-2680"
      }
    ]
  },
  "id": "VAR-201705-3220",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06151"
      },
      {
        "db": "VULHUB",
        "id": "VHN-110883"
      }
    ],
    "trust": 1.5467968472
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06151"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:56:02.371000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-293562",
        "trust": 0.8,
        "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf"
      },
      {
        "title": "Patch for a number of Siemens products with a denial of service vulnerability (CNVD-2017-06151)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/93364"
      },
      {
        "title": "Multiple Siemens Product security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=70052"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-06151"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004134"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-574"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-400",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-20",
        "trust": 0.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-110883"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004134"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-2680"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.8,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-023-02"
      },
      {
        "trust": 2.0,
        "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf"
      },
      {
        "trust": 1.7,
        "url": "http://www.securityfocus.com/bid/98369"
      },
      {
        "trust": 1.7,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
      },
      {
        "trust": 1.7,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf"
      },
      {
        "trust": 1.7,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf"
      },
      {
        "trust": 1.7,
        "url": "http://www.securitytracker.com/id/1038463"
      },
      {
        "trust": 1.1,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-17-129-02"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-284673.html"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html"
      },
      {
        "trust": 0.9,
        "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-2680"
      },
      {
        "trust": 0.8,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-128-01"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-2680"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-17-129-02"
      },
      {
        "trust": 0.3,
        "url": "http://subscriber.communications.siemens.com/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-06151"
      },
      {
        "db": "VULHUB",
        "id": "VHN-110883"
      },
      {
        "db": "BID",
        "id": "98369"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004134"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-574"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-2680"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06151"
      },
      {
        "db": "VULHUB",
        "id": "VHN-110883"
      },
      {
        "db": "BID",
        "id": "98369"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004134"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-574"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-2680"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-05-09T00:00:00",
        "db": "IVD",
        "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4"
      },
      {
        "date": "2017-05-09T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2017-06151"
      },
      {
        "date": "2017-05-11T00:00:00",
        "db": "VULHUB",
        "id": "VHN-110883"
      },
      {
        "date": "2017-05-08T00:00:00",
        "db": "BID",
        "id": "98369"
      },
      {
        "date": "2017-06-16T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-004134"
      },
      {
        "date": "2017-05-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201705-574"
      },
      {
        "date": "2017-05-11T01:29:05.400000",
        "db": "NVD",
        "id": "CVE-2017-2680"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-05-09T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2017-06151"
      },
      {
        "date": "2020-09-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-110883"
      },
      {
        "date": "2018-05-09T14:00:00",
        "db": "BID",
        "id": "98369"
      },
      {
        "date": "2018-05-10T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-004134"
      },
      {
        "date": "2022-02-11T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201705-574"
      },
      {
        "date": "2024-11-21T03:23:57.563000",
        "db": "NVD",
        "id": "CVE-2017-2680"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote or local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-574"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Siemens Service disruption in products  (DoS) Vulnerabilities",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004134"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "resource management error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-574"
      }
    ],
    "trust": 0.6
  }
}

var-201705-3221
Vulnerability from variot

Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected. SIMATIC HMI is an industrial device from Siemens AG, Germany. The SIMATIC HMI panels are used for operator control and monitoring of machines and equipment. Multiple Siemens Products is prone to multiple denial-of-service vulnerabilities. Attackers can exploit these issues to cause a denial-of-service condition. Manual restart of the server is required to resume normal operation. A vulnerability has been identified in SIMATIC CP 343-1 Std (All versions), SIMATIC CP 343-1 Lean (All versions), SIMATIC CP 343-1 Adv (All versions), SIMATIC CP 443-1 Std (All versions < V3.2.17), SIMATIC CP 443-1 Adv (All versions < V3.2.17), SIMATIC CP 443-1 OPC-UA (All versions), SIMATIC CP 1243-1 (All versions < V2.1.82), SIMATIC CP 1243-1 IRC (All versions < V2.1.82), SIMATIC CP 1243-1 IEC (All versions), SIMATIC CP 1243-1 DNP3 (All versions), SIMATIC CM 1542-1 (All versions < V2.0), SIMATIC CM 1542SP-1 (All versions < V1.0.15), SIMATIC CP 1542SP-1 IRC (All versions < V1.0.15), SIMATIC CP 1543SP-1 (All versions < V1.0.15), SIMATIC CP 1543-1 (All versions < V2.1), SIMATIC RF650R (All versions < V3.0), SIMATIC RF680R (All versions < V3.0), SIMATIC RF685R (All versions < V3.0), SIMATIC CP 1616 (All versions < V2.7), SIMATIC CP 1604 (All versions < V2.7), SIMATIC DK-16xx PN IO (All versions < V2.7), SCALANCE X-200 (All versions < V5.2.2), SCALANCE X-200 IRT (All versions), SCALANCE X-300/X408 (All versions < V4.1.0), SCALANCE X414 (All versions < V3.10.2), SCALANCE XM400 (All versions < V6.1), SCALANCE XR500 (All versions < V6.1), SCALANCE W700 (All versions < V6.1), SCALANCE M-800, S615 (All versions < V4.03), Softnet PROFINET IO for PC-based Windows systems (All versions < V14 SP1), IE/PB-Link (All versions < V3.0), IE/AS-i Link PN IO (All versions), SIMATIC Teleservice Adapter Standard Modem, IE Basic, IE Advanced (All versions), SITOP PSU8600 PROFINET (All versions < V1.2.0), SITOP UPS1600 PROFINET (All versions < V2.2.0), SIMATIC ET 200AL (All versions < V1.0.2), SIMATIC ET 200ecoPN (All versions), SIMATIC ET 200M (All versions), SIMATIC ET 200MP IM155-5 PN BA (All versions < V4.0.1), SIMATIC ET 200MP IM155-5 PN ST (All versions < V4.1), SIMATIC ET 200MP (except IM155-5 PN BA and IM155-5 PN ST) (All versions), SIMATIC ET 200pro (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200SP IM155-6 PN ST (All versions < V4.1.0), SIMATIC ET 200SP (except IM155-6 PN ST) (All versions), SIMATIC PN/PN Coupler (All versions < V4.0), Development/Evaluation Kit DK Standard Ethernet Controller (All versions < V4.1.1 Patch04), Development/Evaluation Kit EK-ERTEC 200P (All versions < V4.4.0 Patch01), Development/Evaluation Kit EK-ERTEC 200 (All versions < V4.2.1 Patch03), SIMATIC S7-200 SMART (All versions < V2.3), SIMATIC S7-300 incl. F and T (All versions < V3.X.14), SIMATIC S7-400 PN/DP V6 Incl. F (All versions < V6.0.6), SIMATIC S7-400-H V6 (All versions < V6.0.7), SIMATIC S7-400 PN/DP V7 Incl. F (All versions < V7.0.2), SIMATIC S7-410 (All versions < V8.2), SIMATIC S7-1200 incl. F (All versions < V4.2.1), SIMATIC S7-1500 incl. F, T, and TF (All versions < V2.1), SIMATIC S7-1500 Software Controller incl. F (All versions < V2.1), SIMATIC WinAC RTX 2010 incl. F (All versions), SIRIUS ACT 3SU1 interface module PROFINET (All versions), SIRIUS Soft Starter 3RW44 PN (All versions), SIRIUS Motor Starter M200D PROFINET (All versions), SIMOCODE pro V PROFINET (All versions < V2.0.0), SINAMICS DCM w. PN (All versions < V1.4 SP1 HF5), SINAMICS DCP w. PN (All versions < V1.2 HF 1), SINAMICS G110M w. PN (All versions < V4.7 SP6 HF3), SINAMICS G120(C/P/D) w. PN (All versions < V4.7 SP6 HF3), SINAMICS G130 V4.7 w. PN (All versions < V4.7 HF27), SINAMICS G150 V4.7 w. PN (V4.7: All versions < V4.7 HF27), SINAMICS G130 V4.8 w. PN (All versions < V4.8 HF4), SINAMICS G150 V4.8 w. PN (All versions < V4.8 HF4), SINAMICS S110 w. PN (All versions < V4.4 SP3 HF5), SINAMICS S120 V4.7 w. PN (All versions < V4.7 HF27), and others. This vulnerability affects only SIMATIC HMI Multi Panels and HMI Mobile Panels, and S7-300/S7-400 devices. Siemens SIMATIC S7-300 F, etc. Siemens SIMATIC S7-300 F is a process controller. SIMATIC HMI Comfort Panels are touch screens

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201705-3221",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "sinumerik 840d sl",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinumerik 840d sl",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "sinumerik 828d",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinumerik 828d",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi mobile panels",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic rf650r",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.0"
      },
      {
        "model": "dk standard ethernet controller",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.1"
      },
      {
        "model": "sinamics s110 pn",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.4"
      },
      {
        "model": "scalance x414",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.10.2"
      },
      {
        "model": "simatic et 200sp",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.2.0"
      },
      {
        "model": "scalance x200 irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.4.0"
      },
      {
        "model": "simatic cp 1243-1 dnp3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic cp 1616",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.7"
      },
      {
        "model": "sinamics g150",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "simatic cm 1542sp-1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.0.15"
      },
      {
        "model": "sinamics g130",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics s120",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "simatic cp 1604",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.7"
      },
      {
        "model": "sinamics s110 pn",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.4"
      },
      {
        "model": "simatic s7-1200",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.2.1"
      },
      {
        "model": "ek-ertec 200p pn io",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.4.0"
      },
      {
        "model": "ie\\/pb-link",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.0"
      },
      {
        "model": "simatic cm 1542-1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.0"
      },
      {
        "model": "sirius motor starter m200d profinet",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "sinumerik 840d sl",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "simatic rf680r",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.0"
      },
      {
        "model": "simatic cp 1243-1 irc",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.1.82"
      },
      {
        "model": "sinamics dcp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.2"
      },
      {
        "model": "simotion",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "simatic cp 343-1 adv",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic cp 443-1 opc-ua",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic et 200s",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "dk standard ethernet controller",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.1"
      },
      {
        "model": "simatic teleservice adapter ie advanced modem",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic tdc cpu555",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.1.1"
      },
      {
        "model": "simatic et 200al",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.0.2"
      },
      {
        "model": "simatic dk-16xx pn io",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.7"
      },
      {
        "model": "sinamics g150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics g110m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "simatic s7-300",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.3.17"
      },
      {
        "model": "simatic cp 1543sp-1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.0.15"
      },
      {
        "model": "scalance xr500",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.1"
      },
      {
        "model": "simatic et 200ecopn",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "ek-ertec 200 pn io",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.2.1"
      },
      {
        "model": "softnet profinet io",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "14"
      },
      {
        "model": "scalance m-800",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.03"
      },
      {
        "model": "simatic hmi multi panels",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "scalance s615",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.03"
      },
      {
        "model": "simatic cp 443-1 adv",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.2.17"
      },
      {
        "model": "sinamics dcp",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.2"
      },
      {
        "model": "simatic teleservice adapter ie basic modem",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simotion",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "sitop psu8600",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.2.0"
      },
      {
        "model": "sinumerik 840d sl",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "simatic hmi mobile panels",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "scalance x200",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.2"
      },
      {
        "model": "simatic s7-1500",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.1"
      },
      {
        "model": "simatic cp 343-1 std",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.1.3"
      },
      {
        "model": "simatic cp 1243-1 iec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic et 200pro",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "sinamics g110m",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "scalance xm400",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.1"
      },
      {
        "model": "scalance x408",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.0"
      },
      {
        "model": "simatic cp 343-1 lean",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.1.3"
      },
      {
        "model": "sirius act 3su1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.1.0"
      },
      {
        "model": "ek-ertec 200 pn io",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.2.1"
      },
      {
        "model": "simatic tdc cp51m1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.1.8"
      },
      {
        "model": "softnet profinet io",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "14"
      },
      {
        "model": "simatic et 200mp",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.0.1"
      },
      {
        "model": "sinamics dcm",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.4"
      },
      {
        "model": "simatic s7-200 smart",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3"
      },
      {
        "model": "simatic cp 1543-1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.0.15"
      },
      {
        "model": "scalance w700",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.1"
      },
      {
        "model": "simatic et 200m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "sinumerik 828d",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "simatic winac rtx",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2010"
      },
      {
        "model": "simatic cp 1543sp-1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.1"
      },
      {
        "model": "sinamics s150",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "simatic cp 1542sp-1 irc",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.0.15"
      },
      {
        "model": "simatic cp 443-1 std",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.2.17"
      },
      {
        "model": "simatic s7-400",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.0.6"
      },
      {
        "model": "sirius soft starter 3rw44 pn",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simocode pro v profinet",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.0.0"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "ups1600 profinet",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.2.0"
      },
      {
        "model": "sinamics dcm",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.4"
      },
      {
        "model": "simatic cp 1243-1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.1.82"
      },
      {
        "model": "ie\\/as-i link pn io",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic s7-1500 software controller",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.1"
      },
      {
        "model": "sinamics v90 pn",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.01"
      },
      {
        "model": "scalance x300",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.0"
      },
      {
        "model": "simatic winac rtx",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2010"
      },
      {
        "model": "sinamics g130",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics s120",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "simatic rf685r",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.0"
      },
      {
        "model": "ek-ertec 200p pn io",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.4.0"
      },
      {
        "model": "sinamics s150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "simatic teleservice adapter standard modem",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "pn\\/pn coupler",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.0"
      },
      {
        "model": "sinumerik 828d",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "sinamics g120\\ pn",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "dk standard ethernet controller",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "ek-ertec 200 pn io",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "ek-ertec 200p pn io",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "ie/as-i link pn io",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "ie/pb-link",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "pn/pn coupler",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance m-800",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance s615",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w700",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance x200 irt",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance x200",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance x300",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance x408",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance x414",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xm400",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xr500",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cm 1542-1",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1243-1",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1542sp-1 irc",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1542sp-1",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1543-1",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1543sp-1",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1604",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1616",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 343-1 adv",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 343-1 lean",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 343-1 std",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 443-1 adv",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 443-1 opc-ua",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 443-1 std",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic dk-16xx pn io",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200al",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200ecopn",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200m",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200mp",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200pro",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200s",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200sp",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi multi panels",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic rf650r",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic rf680r",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic rf685r",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-1200",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-1500 software controller",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-1500",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-200 smart",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-300",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-400",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic teleservice adapter ie advanced",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic teleservice adapter ie basic",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic teleservice adapter standard modem",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic winac rtx 2010",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simocode pro v profinet",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simotion",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics dcm",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics dcp",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g110m",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g120 w. pn",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g130",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g150",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s110 w. pn",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s120",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s150",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics v90 w. pn",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinumerik 828d",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinumerik 840d sl",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sirius act 3su1 interface module profinet",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sirius motor starter m200d profinet",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sirius soft starter 3rw44 pn",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sitop psu8600",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sitop ups1600 profinet",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "softnet profinet io",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "for pc-based windows systems firmware"
      },
      {
        "model": "simatic hmi multi panels",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g150",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simatic hmi mobile panels",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s120",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s110 w. pn",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.4,
        "vendor": "sinumerik 828d",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.4,
        "vendor": "sinumerik 840d sl",
        "version": "*"
      },
      {
        "model": "ups1600 profinet",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "softnet profinet io",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sitop psu8600",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sirius soft starter 3rw44 pn",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sirius act 3su1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sinumerik 840d",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sinumerik 828d",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sinamics sm150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics sm120",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics sl150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7.5"
      },
      {
        "model": "sinamics sl150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7.4"
      },
      {
        "model": "sinamics sl150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics gm150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics gl150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics gh150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simotion",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic winac rtx",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "20100"
      },
      {
        "model": "simatic teleservice adapter standard modem",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic s7-400",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic s7-300",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic s7-200 smart",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic s7-1500",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic rf685r",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic rf680r",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic rf650r",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic et",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2000"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "443-10"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "343-10"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "16260"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "16160"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "16040"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1543-12.0.28"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1543-10"
      },
      {
        "model": "simatic cp 1542sp-1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic cp irc",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1243-80"
      },
      {
        "model": "simatic cp lte eu/us",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1243-70"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1243-10"
      },
      {
        "model": "simatic cp gprs",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1242-7v20"
      },
      {
        "model": "scalance xr500",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "scalance xm400",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "x4140"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "x4084.0"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "x4083.0"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "x3000"
      },
      {
        "model": "scalance irt",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "x2000"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "x2000"
      },
      {
        "model": "scalance w700 series",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.4"
      },
      {
        "model": "scalance w700 series",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.5.4"
      },
      {
        "model": "scalance s615",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "scalance m-800",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.02"
      },
      {
        "model": "scalance m-800",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "ie/as-i link pn io",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "extension unit profinet",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "22?0"
      },
      {
        "model": "extension unit profinet",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "19?0"
      },
      {
        "model": "extension unit profinet",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15?0"
      },
      {
        "model": "extension unit profinet",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "12?0"
      },
      {
        "model": "e/pb-link",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sinumerik 840d sl",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinumerik 828d",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics sm120 sp2",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics sl150 sp2",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics gm150 sp2",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics gl150 sp2",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics gh150 sp2",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simatic rf685r",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "3.0"
      },
      {
        "model": "simatic rf680r",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "3.0"
      },
      {
        "model": "simatic cp",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "16162.7"
      },
      {
        "model": "simatic cp 1604d",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2.7"
      },
      {
        "model": "simatic cp irc",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1243-82.1.82"
      },
      {
        "model": "simatic cp lte eu/us",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1243-72.1.82"
      },
      {
        "model": "simatic cp gprs",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1242-7v22.1.82"
      },
      {
        "model": "simatic rf650r",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "3.0"
      },
      {
        "model": "simatic cp",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "443-13.2.17"
      },
      {
        "model": "simatic cp",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15431.2.1"
      },
      {
        "model": "simatic cm1542",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1.2"
      },
      {
        "model": "scalance w700",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "6.1"
      },
      {
        "model": "extension unit profinet",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "22?1.1.1"
      },
      {
        "model": "extension unit profinet",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "19?1.1.1"
      },
      {
        "model": "extension unit profinet",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15?1.1.1"
      },
      {
        "model": "extension unit profinet",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "12?1.1.1"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 343 1 std",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 1542sp 1 irc",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 1543sp 1",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 1543 1",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic rf650r",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic rf680r",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic rf685r",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 1616",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 1604",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic dk 16xx pn io",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance x200",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 343 1 lean",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance x200 irt",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance x300",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance x408",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance x414",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance xm400",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance xr500",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance w700",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance m 800",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance s615",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "softnet profinet io",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 343 1 adv",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "ie pb link",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "ie as i link pn io",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic teleservice adapter standard modem",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic teleservice adapter ie basic modem",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic teleservice adapter ie advanced modem",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sitop psu8600",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "ups1600 profinet",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200al",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200ecopn",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200m",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 443 1 std",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200mp",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200pro",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200s",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200sp",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "pn pn coupler",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dk standard ethernet controller",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "ek ertec 200p pn io",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "ek ertec 200 pn io",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 200 smart",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 300",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 443 1 adv",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 400",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1200",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1500",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1500 controller",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic winac rtx 2010",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sirius act 3su1",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sirius soft starter 3rw44 pn",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sirius motor starter m200d profinet",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simocode pro v profinet",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics dcm",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 443 1 opc ua",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics dcp",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics g110m",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics g120 c p d w pn",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics g130",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics g150",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics s110 w pn",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics s120",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics s150",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics v90 w pn",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simotion",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 1243 1",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi comfort panels",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi multi panels",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi mobile panels",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cm 1542 1",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 1542sp 1",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "33467505-7492-4ae1-b978-12f61201709a"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06153"
      },
      {
        "db": "BID",
        "id": "98369"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004135"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-639"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-2681"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:siemens:dk_standard_ethernet_controller_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:ek-ertec_200_pn_io_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:ek-ertec_200p_pn_io_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:ie%2Fpb-link_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:ie%2Fas-i_link_pn_io_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:pn%2Fpn_coupler_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:scalance_m-800_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:scalance_s615_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:scalance_w700_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:scalance_x200irt_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:scalance_x200_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:scalance_x300_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:scalance_x408_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:scalance_x414_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:scalance_xm400_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:scalance_xr500_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cm_1542-1_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cp_1243-1_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cp_1542sp-1_irc_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cp_1542sp-1_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cp_1543-1_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cp_1543sp-1_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cp_1604_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cp_1616_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cp_343-1_lean_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cp_343-1_adv_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cp_343-1_std_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cp_443-1_adv_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cp_443-1_std_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cp_443-1_opc-ua_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_dk-16xx_pn_io_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_et_200al_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_et_200ecopn_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_et_200m_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_et_200mp_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_et_200pro_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_et_200s_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_et_200sp_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_panels",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_mobile_panels",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_multi_panels",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_rf650r_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_rf680r_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_rf685r_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_s7-1200_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_s7-1500_software_controller_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_s7-1500_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_s7-200_smart_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_s7-300_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_s7-400_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_teleservice_adapter_ie_advanced_modem_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_teleservice_adapter_ie_basic_modem_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_teleservice_adapter_standard_modem_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_winac_rtx_2010_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simocode_pro_v_profinet_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simotion_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sinamics_dcm_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sinamics_dcp_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sinamics_g110m_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sinamics_g120%28c%2Fp%2Fd%29_w._pn_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sinamics_g130_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sinamics_g150_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sinamics__s110_w._pn_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sinamics_s120_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sinamics_s150_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sinamics_v90_w._pn_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sinumerik_828d_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sinumerik_840d_sl_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sirius_act_3su1_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sirius_motor_starter_m200d_profinet_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sirius_soft_starter_3rw44_pn_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:sitop_psu8600_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:ups1600_profinet_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:softnet_profinet_io_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004135"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Duan JinTong, Ma ShaoShuai, and Cheng Lei from NSFOCUS Security Team.",
    "sources": [
      {
        "db": "BID",
        "id": "98369"
      }
    ],
    "trust": 0.3
  },
  "cve": "CVE-2017-2681",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "[email protected]",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.1,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "id": "CVE-2017-2681",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.1,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "id": "CNVD-2017-06153",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.1,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "id": "33467505-7492-4ae1-b978-12f61201709a",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.2,
            "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.1,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "id": "VHN-110884",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:A/AC:L/AU:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "author": "[email protected]",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.8,
            "id": "CVE-2017-2681",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 2.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Adjacent Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 6.5,
            "baseSeverity": "Medium",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2017-2681",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "[email protected]",
            "id": "CVE-2017-2681",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "[email protected]",
            "id": "CVE-2017-2681",
            "trust": 1.0,
            "value": "High"
          },
          {
            "author": "NVD",
            "id": "CVE-2017-2681",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2017-06153",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201705-639",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "IVD",
            "id": "33467505-7492-4ae1-b978-12f61201709a",
            "trust": 0.2,
            "value": "MEDIUM"
          },
          {
            "author": "VULHUB",
            "id": "VHN-110884",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "33467505-7492-4ae1-b978-12f61201709a"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06153"
      },
      {
        "db": "VULHUB",
        "id": "VHN-110884"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004135"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-639"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-2681"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-2681"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected. SIMATIC HMI is an industrial device from Siemens AG, Germany. The SIMATIC HMI panels are used for operator control and monitoring of machines and equipment. Multiple Siemens Products is prone to multiple denial-of-service vulnerabilities. \nAttackers can exploit these issues to cause a denial-of-service condition. Manual restart of the server is required to resume normal operation. A vulnerability has been identified in SIMATIC CP 343-1 Std (All versions), SIMATIC CP 343-1 Lean (All versions), SIMATIC CP 343-1 Adv (All versions), SIMATIC CP 443-1 Std (All versions \u003c V3.2.17), SIMATIC CP 443-1 Adv (All versions \u003c V3.2.17), SIMATIC CP 443-1 OPC-UA (All versions), SIMATIC CP 1243-1 (All versions \u003c V2.1.82), SIMATIC CP 1243-1 IRC (All versions \u003c V2.1.82), SIMATIC CP 1243-1 IEC (All versions), SIMATIC CP 1243-1 DNP3 (All versions), SIMATIC CM 1542-1 (All versions \u003c V2.0), SIMATIC CM 1542SP-1 (All versions \u003c V1.0.15), SIMATIC CP 1542SP-1 IRC (All versions \u003c V1.0.15), SIMATIC CP 1543SP-1 (All versions \u003c V1.0.15), SIMATIC CP 1543-1 (All versions \u003c V2.1), SIMATIC RF650R (All versions \u003c V3.0), SIMATIC RF680R (All versions \u003c V3.0), SIMATIC RF685R (All versions \u003c V3.0), SIMATIC CP 1616 (All versions \u003c V2.7), SIMATIC CP 1604 (All versions \u003c V2.7), SIMATIC DK-16xx PN IO (All versions \u003c V2.7), SCALANCE X-200 (All versions \u003c V5.2.2), SCALANCE X-200 IRT (All versions), SCALANCE X-300/X408 (All versions \u003c V4.1.0), SCALANCE X414 (All versions \u003c V3.10.2), SCALANCE XM400 (All versions \u003c V6.1), SCALANCE XR500 (All versions \u003c V6.1), SCALANCE W700 (All versions \u003c V6.1), SCALANCE M-800, S615 (All versions \u003c V4.03), Softnet PROFINET IO for PC-based Windows systems (All versions \u003c V14 SP1), IE/PB-Link (All versions \u003c V3.0), IE/AS-i Link PN IO (All versions), SIMATIC Teleservice Adapter Standard Modem, IE Basic, IE Advanced (All versions), SITOP PSU8600 PROFINET (All versions \u003c V1.2.0), SITOP UPS1600 PROFINET (All versions \u003c V2.2.0), SIMATIC ET 200AL (All versions \u003c V1.0.2), SIMATIC ET 200ecoPN (All versions), SIMATIC ET 200M (All versions), SIMATIC ET 200MP IM155-5 PN BA (All versions \u003c V4.0.1), SIMATIC ET 200MP IM155-5 PN ST (All versions \u003c V4.1), SIMATIC ET 200MP (except IM155-5 PN BA and IM155-5 PN ST) (All versions), SIMATIC ET 200pro (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200SP IM155-6 PN ST (All versions \u003c V4.1.0), SIMATIC ET 200SP (except IM155-6 PN ST) (All versions), SIMATIC PN/PN Coupler (All versions \u003c V4.0), Development/Evaluation Kit DK Standard Ethernet Controller (All versions \u003c V4.1.1 Patch04), Development/Evaluation Kit EK-ERTEC 200P (All versions \u003c V4.4.0 Patch01), Development/Evaluation Kit EK-ERTEC 200 (All versions \u003c V4.2.1 Patch03), SIMATIC S7-200 SMART (All versions \u003c V2.3), SIMATIC S7-300 incl. F and T (All versions \u003c V3.X.14), SIMATIC S7-400 PN/DP V6 Incl. F (All versions \u003c V6.0.6), SIMATIC S7-400-H V6 (All versions \u003c V6.0.7), SIMATIC S7-400 PN/DP V7 Incl. F (All versions \u003c V7.0.2), SIMATIC S7-410 (All versions \u003c V8.2), SIMATIC S7-1200 incl. F (All versions \u003c V4.2.1), SIMATIC S7-1500 incl. F, T, and TF (All versions \u003c V2.1), SIMATIC S7-1500 Software Controller incl. F (All versions \u003c V2.1), SIMATIC WinAC RTX 2010 incl. F (All versions), SIRIUS ACT 3SU1 interface module PROFINET (All versions), SIRIUS Soft Starter 3RW44 PN (All versions), SIRIUS Motor Starter M200D PROFINET (All versions), SIMOCODE pro V PROFINET (All versions \u003c V2.0.0), SINAMICS DCM w. PN (All versions \u003c V1.4 SP1 HF5), SINAMICS DCP w. PN (All versions \u003c V1.2 HF 1), SINAMICS G110M w. PN (All versions \u003c V4.7 SP6 HF3), SINAMICS G120(C/P/D) w. PN (All versions \u003c V4.7 SP6 HF3), SINAMICS G130 V4.7 w. PN (All versions \u003c V4.7 HF27), SINAMICS G150 V4.7 w. PN (V4.7: All versions \u003c V4.7 HF27), SINAMICS G130 V4.8 w. PN (All versions \u003c V4.8 HF4), SINAMICS G150 V4.8 w. PN (All versions \u003c V4.8 HF4), SINAMICS S110 w. PN (All versions \u003c V4.4 SP3 HF5), SINAMICS S120 V4.7 w. PN (All versions \u003c V4.7 HF27), and others. This vulnerability affects only SIMATIC HMI Multi Panels and HMI Mobile Panels, and S7-300/S7-400 devices. Siemens SIMATIC S7-300 F, etc. Siemens SIMATIC S7-300 F is a process controller. SIMATIC HMI Comfort Panels are touch screens",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2017-2681"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004135"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06153"
      },
      {
        "db": "BID",
        "id": "98369"
      },
      {
        "db": "IVD",
        "id": "33467505-7492-4ae1-b978-12f61201709a"
      },
      {
        "db": "VULHUB",
        "id": "VHN-110884"
      }
    ],
    "trust": 2.7
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2017-2681",
        "trust": 3.6
      },
      {
        "db": "SIEMENS",
        "id": "SSA-293562",
        "trust": 2.6
      },
      {
        "db": "BID",
        "id": "98369",
        "trust": 2.0
      },
      {
        "db": "SECTRACK",
        "id": "1038463",
        "trust": 1.7
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-17-129-02",
        "trust": 1.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06153",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-639",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004135",
        "trust": 0.8
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-18-023-02",
        "trust": 0.3
      },
      {
        "db": "SIEMENS",
        "id": "SSA-284673",
        "trust": 0.3
      },
      {
        "db": "IVD",
        "id": "33467505-7492-4AE1-B978-12F61201709A",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-110884",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "33467505-7492-4ae1-b978-12f61201709a"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06153"
      },
      {
        "db": "VULHUB",
        "id": "VHN-110884"
      },
      {
        "db": "BID",
        "id": "98369"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004135"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-639"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-2681"
      }
    ]
  },
  "id": "VAR-201705-3221",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "33467505-7492-4ae1-b978-12f61201709a"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06153"
      },
      {
        "db": "VULHUB",
        "id": "VHN-110884"
      }
    ],
    "trust": 1.5075520524444446
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "33467505-7492-4ae1-b978-12f61201709a"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06153"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:56:02.322000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-293562",
        "trust": 0.8,
        "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf"
      },
      {
        "title": "Patch for Siemens SIMATIC HMI Denial of Service Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/93365"
      },
      {
        "title": "Multiple Siemens Product security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=70109"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-06153"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004135"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-639"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-400",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-20",
        "trust": 0.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-110884"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004135"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-2681"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.6,
        "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf"
      },
      {
        "trust": 1.7,
        "url": "http://www.securityfocus.com/bid/98369"
      },
      {
        "trust": 1.7,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
      },
      {
        "trust": 1.7,
        "url": "http://www.securitytracker.com/id/1038463"
      },
      {
        "trust": 1.1,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-17-129-02"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-2681"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-2681"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-17-129-02"
      },
      {
        "trust": 0.3,
        "url": "http://subscriber.communications.siemens.com/"
      },
      {
        "trust": 0.3,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-023-02"
      },
      {
        "trust": 0.3,
        "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-06153"
      },
      {
        "db": "VULHUB",
        "id": "VHN-110884"
      },
      {
        "db": "BID",
        "id": "98369"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004135"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-639"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-2681"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "33467505-7492-4ae1-b978-12f61201709a"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06153"
      },
      {
        "db": "VULHUB",
        "id": "VHN-110884"
      },
      {
        "db": "BID",
        "id": "98369"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004135"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-639"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-2681"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-05-09T00:00:00",
        "db": "IVD",
        "id": "33467505-7492-4ae1-b978-12f61201709a"
      },
      {
        "date": "2017-05-09T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2017-06153"
      },
      {
        "date": "2017-05-11T00:00:00",
        "db": "VULHUB",
        "id": "VHN-110884"
      },
      {
        "date": "2017-05-08T00:00:00",
        "db": "BID",
        "id": "98369"
      },
      {
        "date": "2017-06-16T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-004135"
      },
      {
        "date": "2017-05-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201705-639"
      },
      {
        "date": "2017-05-11T10:29:00.180000",
        "db": "NVD",
        "id": "CVE-2017-2681"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-05-09T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2017-06153"
      },
      {
        "date": "2020-09-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-110884"
      },
      {
        "date": "2018-05-09T14:00:00",
        "db": "BID",
        "id": "98369"
      },
      {
        "date": "2017-09-11T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-004135"
      },
      {
        "date": "2022-03-10T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201705-639"
      },
      {
        "date": "2024-11-21T03:23:57.917000",
        "db": "NVD",
        "id": "CVE-2017-2681"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote or local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-639"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens SIMATIC HMI Denial of service vulnerability",
    "sources": [
      {
        "db": "IVD",
        "id": "33467505-7492-4ae1-b978-12f61201709a"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06153"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "resource management error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-639"
      }
    ],
    "trust": 0.6
  }
}

var-201910-1596
Vulnerability from variot

An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation. Multiple Siemens products are vulnerable to resource exhaustion.Service operation interruption (DoS) There is a possibility of being put into a state. The Siemens SIMATIC S7-300 CPU is a modular universal controller for the manufacturing industry from Siemens. The products in the Siemens SIMATIC S7-400 CPU family have been designed for process control in industrial environments. SIMATIC WinAC RTX (F) 2010 is a simatic software controller for PC-based automation solutions. Siemens SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLCs) or human machine interfaces (HMIs).

A denial of service vulnerability exists in several Siemens products. A vulnerability has been identified in CP1604 (All versions < V2.8), CP1616 (All versions < V2.8), Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions < V4.1.1 Patch 05), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions < V4.5.0 Patch 01), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions < V4.5.0), SCALANCE X-200IRT (All versions < V5.2.1), SIMATIC ET 200M (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200ecoPN (except 6ES7148-6JD00-0AB0 and 6ES7146-6FF00-0AB0) (All versions), SIMATIC ET 200pro (All versions), SIMATIC PN/PN Coupler 6ES7158-3AD01-0XA0 (All versions), SIMATIC S7-300 CPU family (incl. F) (All versions), SIMATIC S7-400 (incl. F) V6 and below (All versions), SIMATIC S7-400 PN/DP V7 (incl. F) (All versions), SIMATIC WinAC RTX (F) 2010 (All versions < SIMATIC WinAC RTX 2010 SP3), SIMOTION (All versions), SINAMICS DCM (All versions < V1.5 HF1), SINAMICS DCP (All versions), SINAMICS G110M V4.7 (Control Unit) (All versions < V4.7 SP10 HF5), SINAMICS G120 V4.7 (Control Unit) (All versions < V4.7 SP10 HF5), SINAMICS G130 V4.7 (Control Unit) (All versions < V4.7 HF29), SINAMICS G150 (Control Unit) (All versions < V4.8), SINAMICS GH150 V4.7 (Control Unit) (All versions), SINAMICS GL150 V4.7 (Control Unit) (All versions), SINAMICS GM150 V4.7 (Control Unit) (All versions), SINAMICS S110 (Control Unit) (All versions), SINAMICS S120 V4.7 (Control Unit and CBE20) (All versions < V4.7 HF34), SINAMICS S150 (Control Unit) (All versions < V4.8), SINAMICS SL150 V4.7 (Control Unit) (All versions), SINAMICS SM120 V4.7 (Control Unit) (All versions), SINUMERIK 828D (All versions < V4.8 SP5), SINUMERIK 840D sl (All versions). No user interaction is required to exploit this security vulnerability. The vulnerability impacts the availability of the affected installations. Siemens CP1616, etc. are all products of Siemens (Siemens) in Germany. CP1616 is a communications processor. SINUMERIK 840D sl is a set of advanced machine tool numerical control system. SCALANCE X-200IRT is an industrial Ethernet switch. The following products and versions are affected: Siemens SIMATIC NET CP 1616 before V2.8; SINUMERIK 840D sl (all versions); SCALANCE X-200IRT series (including SIPLUS NET variants) before V5.2.1; SIMATIC ET200S (including SIPLUS variants) (full version) etc

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201910-1596",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "simatic et 200m",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200s",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200ecopn",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic pn/pn coupler 6es7158-3ad01-0xa0",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 1.0,
        "vendor": "sinumerik 828d",
        "version": "4.8"
      },
      {
        "model": "simatic s7-300 cpu 312 ifm",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.3.17"
      },
      {
        "model": "dk standard ethernet controller",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.1"
      },
      {
        "model": "simatic s7-400 dp v7",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "sinamics g110m",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics gh150",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simatic s7-300 cpu 314",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.3.17"
      },
      {
        "model": "simatic s7-300 cpu 313",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.3.17"
      },
      {
        "model": "simatic s7-300 cpu 316-2 dp",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.3.17"
      },
      {
        "model": "sinamics gl150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics gm150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "cp1604",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.8"
      },
      {
        "model": "sinamics g120",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics sl150",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinumerik 828d",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics g130",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "simatic s7-300 cpu",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.3.17"
      },
      {
        "model": "sinamics s120",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "simatic pn\\/pn coupler 6es7158-3ad01-0xa0",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic winac rtx \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2010"
      },
      {
        "model": "sinumerik 840d sl",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "ek-ertec 200",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5.0"
      },
      {
        "model": "simatic et 200m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic s7-300 cpu 314 ifm",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.3.17"
      },
      {
        "model": "simatic s7-400 v6",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x-200irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.1"
      },
      {
        "model": "simatic s7-300 cpu 315-2 dp",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.3.17"
      },
      {
        "model": "sinamics dcm",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.5"
      },
      {
        "model": "cp1616",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.8"
      },
      {
        "model": "simatic et 200s",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "dk standard ethernet controller",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.1"
      },
      {
        "model": "sinamics gm150",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "ek-ertec 200p",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5.0"
      },
      {
        "model": "sinamics g110m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics sm120",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic s7-300 cpu 315",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.3.17"
      },
      {
        "model": "sinamics g150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics gh150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinumerik 828d",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simotion",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic winac rtx \\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2010"
      },
      {
        "model": "simatic et 200ecopn",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "ek-ertec 200",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5.0"
      },
      {
        "model": "sinamics dcp",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.3"
      },
      {
        "model": "sinamics gl150",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simatic s7-400 pn v7",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "sinamics s110",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "sinamics g120",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics sl150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics g130",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics s120",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics dcm",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.5"
      },
      {
        "model": "sinamics s150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simatic s7-300 cpu 318-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.3.17"
      },
      {
        "model": "cp1604",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "cp1616",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "dk standard ethernet controller",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "ek-ertec 200",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "ek-ertec 200p p",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance x-200irt",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200pro",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics dcp",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinumerik 840d sl",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "cp1604",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v2.8"
      },
      {
        "model": "cp1616",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v2.8"
      },
      {
        "model": "dk standard ethernet controller patch",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v4.1.105"
      },
      {
        "model": "ek-ertec 200p patch",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v4.5.001"
      },
      {
        "model": "ek-ertec 200p",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v4.5.0"
      },
      {
        "model": "scalance x-200irt",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v5.2.1"
      },
      {
        "model": "simatic s7-300 cpu family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-400 and below",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v6"
      },
      {
        "model": "simatic winac rtx",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "2010"
      },
      {
        "model": "simatic s7-400 pn/dp",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v7"
      },
      {
        "model": "sinamics dcm hf1",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v1.5"
      },
      {
        "model": "sinumerik 828d sp5",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v4.8"
      },
      {
        "model": "sinamics g110m sp10 hf5",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v4.7\u003cv4.7"
      },
      {
        "model": "sinamics g120 sp10 hf5",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v4.7\u003cv4.7"
      },
      {
        "model": "sinamics g130 hf29",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v4.7\u003cv4.7"
      },
      {
        "model": "sinamics g150",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v4.8"
      },
      {
        "model": "sinamics gh150",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v4.7"
      },
      {
        "model": "sinamics gl150",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v4.7"
      },
      {
        "model": "sinamics gm150",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v4.7"
      },
      {
        "model": "sinamics s110",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s120 hf34",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v4.7\u003cv4.7"
      },
      {
        "model": "sinamics s150",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v4.8"
      },
      {
        "model": "sinamics sl150",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v4.7"
      },
      {
        "model": "sinamics sm120",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v4.7"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.4,
        "vendor": "dk standard ethernet controller",
        "version": "4.1.1"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "cp1604",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic pn pn coupler 6es7158 3ad01 0xa0",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 300 cpu",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 300 cpu 312 ifm",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 300 cpu 313",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 300 cpu 314",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 300 cpu 314 ifm",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 300 cpu 315",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 300 cpu 315 2 dp",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 300 cpu 316 2 dp",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 300 cpu 318 2",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "cp1616",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 400 v6",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 400 pn v7",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 400 dp v7",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic winac rtx f 2010",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simotion",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics dcm",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics dcm",
        "version": "1.5"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics dcp",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics g110m",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics g110m",
        "version": "4.7"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics g120",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics g120",
        "version": "4.7"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics g130",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics g130",
        "version": "4.7"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dk standard ethernet controller",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics g150",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics gh150",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics gl150",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics gm150",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics s110",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics s120",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics s120",
        "version": "4.7"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics s150",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics sl150",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics sm120",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinumerik 828d",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "ek ertec 200",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "ek ertec 200",
        "version": "4.5.0"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinumerik 840d sl",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "ek ertec 200p",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance x 200irt",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200m",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200s",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200ecopn",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "b7de1c6d-2642-4df7-860f-bfe6735515f5"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-41280"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-010610"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-10923"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:siemens:cp1604_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:cp1616_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:dk_standard_ethernet_controller_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:ek-ertec_200_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:ek-ertec_200p_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:scalance_x-200irt_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_et_200ecopn_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_et_200m_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_et_200s_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_pn%2fpn_coupler_6es7158-3ad01-0xa0_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-010610"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens reported this vulnerability to CISA. Artem Zinenko of Kaspersky reported to Siemens that SIPLUS is also affected.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201910-565"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2019-10923",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "[email protected]",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2019-10923",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2019-41280",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "b7de1c6d-2642-4df7-860f-bfe6735515f5",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-142518",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "[email protected]",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2019-10923",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 2.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.5,
            "baseSeverity": "High",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2019-10923",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "[email protected]",
            "id": "CVE-2019-10923",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "[email protected]",
            "id": "CVE-2019-10923",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2019-10923",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-41280",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201910-565",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "IVD",
            "id": "b7de1c6d-2642-4df7-860f-bfe6735515f5",
            "trust": 0.2,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-142518",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "b7de1c6d-2642-4df7-860f-bfe6735515f5"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-41280"
      },
      {
        "db": "VULHUB",
        "id": "VHN-142518"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-010610"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201910-565"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-10923"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-10923"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation. Multiple Siemens products are vulnerable to resource exhaustion.Service operation interruption (DoS) There is a possibility of being put into a state. The Siemens SIMATIC S7-300 CPU is a modular universal controller for the manufacturing industry from Siemens. The products in the Siemens SIMATIC S7-400 CPU family have been designed for process control in industrial environments. SIMATIC WinAC RTX (F) 2010 is a simatic software controller for PC-based automation solutions. Siemens SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLCs) or human machine interfaces (HMIs). \n\nA denial of service vulnerability exists in several Siemens products. A vulnerability has been identified in CP1604 (All versions \u003c V2.8), CP1616 (All versions \u003c V2.8), Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions \u003c V4.1.1 Patch 05), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions \u003c V4.5.0 Patch 01), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions \u003c V4.5.0), SCALANCE X-200IRT (All versions \u003c V5.2.1), SIMATIC ET 200M (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200ecoPN (except 6ES7148-6JD00-0AB0 and 6ES7146-6FF00-0AB0) (All versions), SIMATIC ET 200pro (All versions), SIMATIC PN/PN Coupler 6ES7158-3AD01-0XA0 (All versions), SIMATIC S7-300 CPU family (incl. F) (All versions), SIMATIC S7-400 (incl. F) V6 and below (All versions), SIMATIC S7-400 PN/DP V7 (incl. F) (All versions), SIMATIC WinAC RTX (F) 2010 (All versions \u003c SIMATIC WinAC RTX 2010 SP3), SIMOTION (All versions), SINAMICS DCM (All versions \u003c V1.5 HF1), SINAMICS DCP (All versions), SINAMICS G110M V4.7 (Control Unit) (All versions \u003c V4.7 SP10 HF5), SINAMICS G120 V4.7 (Control Unit) (All versions \u003c V4.7 SP10 HF5), SINAMICS G130 V4.7 (Control Unit) (All versions \u003c V4.7 HF29), SINAMICS G150 (Control Unit) (All versions \u003c V4.8), SINAMICS GH150 V4.7 (Control Unit) (All versions), SINAMICS GL150 V4.7 (Control Unit) (All versions), SINAMICS GM150 V4.7 (Control Unit) (All versions), SINAMICS S110 (Control Unit) (All versions), SINAMICS S120 V4.7 (Control Unit and CBE20) (All versions \u003c V4.7 HF34), SINAMICS S150 (Control Unit) (All versions \u003c V4.8), SINAMICS SL150 V4.7 (Control Unit) (All versions), SINAMICS SM120 V4.7 (Control Unit) (All versions), SINUMERIK 828D (All versions \u003c V4.8 SP5), SINUMERIK 840D sl (All versions). No user interaction is required to exploit this security vulnerability. The vulnerability impacts the availability of the affected installations. Siemens CP1616, etc. are all products of Siemens (Siemens) in Germany. CP1616 is a communications processor. SINUMERIK 840D sl is a set of advanced machine tool numerical control system. SCALANCE X-200IRT is an industrial Ethernet switch. The following products and versions are affected: Siemens SIMATIC NET CP 1616 before V2.8; SINUMERIK 840D sl (all versions); SCALANCE X-200IRT series (including SIPLUS NET variants) before V5.2.1; SIMATIC ET200S (including SIPLUS variants) (full version) etc",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-10923"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-010610"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-41280"
      },
      {
        "db": "IVD",
        "id": "b7de1c6d-2642-4df7-860f-bfe6735515f5"
      },
      {
        "db": "VULHUB",
        "id": "VHN-142518"
      }
    ],
    "trust": 2.43
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2019-10923",
        "trust": 3.3
      },
      {
        "db": "SIEMENS",
        "id": "SSA-349422",
        "trust": 2.3
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-19-283-01",
        "trust": 1.4
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201910-565",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-41280",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-010610",
        "trust": 0.8
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2019.3812",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2019.3812.2",
        "trust": 0.6
      },
      {
        "db": "IVD",
        "id": "B7DE1C6D-2642-4DF7-860F-BFE6735515F5",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-142518",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "b7de1c6d-2642-4df7-860f-bfe6735515f5"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-41280"
      },
      {
        "db": "VULHUB",
        "id": "VHN-142518"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-010610"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201910-565"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-10923"
      }
    ]
  },
  "id": "VAR-201910-1596",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "b7de1c6d-2642-4df7-860f-bfe6735515f5"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-41280"
      },
      {
        "db": "VULHUB",
        "id": "VHN-142518"
      }
    ],
    "trust": 1.6269844772727273
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "b7de1c6d-2642-4df7-860f-bfe6735515f5"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-41280"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:41:18.618000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-349422",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-349422.pdf"
      },
      {
        "title": "Patch for Multiple Siemens Product Denial of Service Vulnerabilities (CNVD-2019-41280)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/184335"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-41280"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-010610"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-400",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-142518"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-010610"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-10923"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.3,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-349422.pdf"
      },
      {
        "trust": 1.4,
        "url": "https://www.us-cert.gov/ics/advisories/icsa-19-283-01"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-10923"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-349422.html"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-10923"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2019.3812/"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2019.3812.2/"
      },
      {
        "trust": 0.6,
        "url": "https://vigilance.fr/vulnerability/simatic-denial-of-service-via-irt-30559"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-19-283-01"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-41280"
      },
      {
        "db": "VULHUB",
        "id": "VHN-142518"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-010610"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201910-565"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-10923"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "b7de1c6d-2642-4df7-860f-bfe6735515f5"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-41280"
      },
      {
        "db": "VULHUB",
        "id": "VHN-142518"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-010610"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201910-565"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-10923"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-11-19T00:00:00",
        "db": "IVD",
        "id": "b7de1c6d-2642-4df7-860f-bfe6735515f5"
      },
      {
        "date": "2019-10-11T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-41280"
      },
      {
        "date": "2019-10-10T00:00:00",
        "db": "VULHUB",
        "id": "VHN-142518"
      },
      {
        "date": "2019-10-17T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-010610"
      },
      {
        "date": "2019-10-09T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201910-565"
      },
      {
        "date": "2019-10-10T14:15:14.503000",
        "db": "NVD",
        "id": "CVE-2019-10923"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-11-19T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-41280"
      },
      {
        "date": "2023-01-10T00:00:00",
        "db": "VULHUB",
        "id": "VHN-142518"
      },
      {
        "date": "2019-10-17T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-010610"
      },
      {
        "date": "2023-05-10T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201910-565"
      },
      {
        "date": "2024-11-21T04:20:09.600000",
        "db": "NVD",
        "id": "CVE-2019-10923"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201910-565"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Vulnerability related to resource depletion in multiple Siemens products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-010610"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Resource management error",
    "sources": [
      {
        "db": "IVD",
        "id": "b7de1c6d-2642-4df7-860f-bfe6735515f5"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201910-565"
      }
    ],
    "trust": 0.8
  }
}

Vulnerability from fkie_nvd
Published
2017-05-11 01:29
Modified
2025-04-20 01:37
Summary
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.
References
[email protected]http://www.securityfocus.com/bid/98369Third Party Advisory, VDB Entry
[email protected]http://www.securitytracker.com/id/1038463Third Party Advisory, VDB Entry
[email protected]https://cert-portal.siemens.com/productcert/html/ssa-284673.html
[email protected]https://cert-portal.siemens.com/productcert/html/ssa-293562.html
[email protected]https://cert-portal.siemens.com/productcert/html/ssa-546832.html
[email protected]https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdfVendor Advisory
[email protected]https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdfVendor Advisory
[email protected]https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdfVendor Advisory
[email protected]https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02Third Party Advisory, US Government Resource
[email protected]https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdfBroken Link
af854a3a-2127-422b-91ae-364da2661108http://www.securityfocus.com/bid/98369Third Party Advisory, VDB Entry
af854a3a-2127-422b-91ae-364da2661108http://www.securitytracker.com/id/1038463Third Party Advisory, VDB Entry
af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/html/ssa-284673.html
af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/html/ssa-293562.html
af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/html/ssa-546832.html
af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdfVendor Advisory
af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdfVendor Advisory
af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdfVendor Advisory
af854a3a-2127-422b-91ae-364da2661108https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02Third Party Advisory, US Government Resource
af854a3a-2127-422b-91ae-364da2661108https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdfBroken Link
Impacted products
Vendor Product Version
siemens simatic_cp_343-1_std_firmware *
siemens simatic_cp_343-1_std -
siemens simatic_cp_343-1_lean_firmware *
siemens simatic_cp_343-1_lean -
siemens simatic_cp_343-1_adv_firmware *
siemens simatic_cp_343-1_adv -
siemens simatic_cp_443-1_std_firmware *
siemens simatic_cp_443-1_std -
siemens simatic_cp_443-1_adv_firmware *
siemens simatic_cp_443-1_adv -
siemens simatic_cp_443-1_opc-ua_firmware *
siemens simatic_cp_443-1_opc-ua -
siemens simatic_cp_1243-1_firmware *
siemens simatic_cp_1243-1 -
siemens simatic_cm_1542-1_firmware *
siemens simatic_cm_1542-1 -
siemens simatic_cp_1542sp-1_firmware *
siemens simatic_cp_1542sp-1 -
siemens simatic_cp_1542sp-1_irc_firmware *
siemens simatic_cp_1542sp-1_irc -
siemens simatic_cp_1543sp-1_firmware *
siemens simatic_cp_1543sp-1 -
siemens simatic_cp_1543-1_firmware *
siemens simatic_cp_1543-1 -
siemens simatic_rf650r_firmware *
siemens simatic_rf650r -
siemens simatic_rf680r_firmware *
siemens simatic_rf680r -
siemens simatic_rf685r_firmware *
siemens simatic_rf685r -
siemens simatic_cp_1616_firmware *
siemens simatic_cp_1616 -
siemens simatic_cp_1604_firmware *
siemens simatic_cp_1604 -
siemens simatic_dk-1616_pn_io_firmware *
siemens simatic_dk-1616_pn_io -
siemens scalance_x200_firmware *
siemens scalance_x200 -
siemens scalance_x200_irt_firmware *
siemens scalance_x200_irt -
siemens scalance_x300_firmware *
siemens scalance_x300 -
siemens scalance_x408_firmware *
siemens scalance_x408 -
siemens scalance_x414_firmware *
siemens scalance_x414 -
siemens scalance_xm400_firmware *
siemens scalance_xm400 -
siemens scalance_xr500_firmware *
siemens scalance_xr500 -
siemens scalance_w700_firmware *
siemens scalance_w700 -
siemens scalance_m-800_firmware *
siemens scalance_m-800 -
siemens scalance_s615_firmware *
siemens scalance_s615 -
siemens softnet_profinet_io_firmware *
siemens softnet_profinet_io_firmware 14
siemens softnet_profinet_io -
siemens ie\/pb-link_firmware *
siemens ie\/pb-link -
siemens ie\/as-i_link_pn_io_firmware *
siemens ie\/as-i_link_pn_io -
siemens simatic_teleservice_adapter_ie_standard_firmware *
siemens simatic_teleservice_adapter_ie_standard -
siemens simatic_teleservice_adapter_ie_basic_firmware *
siemens simatic_teleservice_adapter_ie_basic -
siemens simatic_teleservice_adapter_ie_advanced_firmware *
siemens simatic_teleservice_adapter_ie_advanced_modem -
siemens sitop_psu8600_firmware *
siemens sitop_psu8600 -
siemens ups1600_profinet_firmware *
siemens ups1600_profinet -
siemens simatic_et_200al_firmware *
siemens simatic_et_200al -
siemens simatic_et_200ecopn_firmware *
siemens simatic_et_200ecopn -
siemens simatic_et_200m_firmware *
siemens simatic_et_200m -
siemens simatic_et_200mp_firmware *
siemens simatic_et_200mp -
siemens simatic_et_200pro_firmware *
siemens simatic_et_200pro -
siemens simatic_et_200s_firmware *
siemens simatic_et_200s -
siemens simatic_et_200sp_firmware *
siemens simatic_et_200sp -
siemens pn\/pn_coupler_firmware *
siemens pn\/pn_coupler -
siemens dk_standard_ethernet_controller_firmware *
siemens dk_standard_ethernet_controller_firmware 4.1.1
siemens dk_standard_ethernet_controller -
siemens ek-ertec_200p_pn_io_firmware *
siemens ek-ertec_200p_pn_io_firmware 4.4.0
siemens ek-ertec_200p_pn_io -
siemens ek-ertec_200_pn_io_firmware *
siemens ek-ertec_200_pn_io_firmware 4.2.1
siemens ek-ertec_200_pn_io -
siemens simatic_s7-200_smart_firmware *
siemens simatic_s7-200_smart -
siemens simatic_s7-300_firmware -
siemens simatic_s7-300 -
siemens simatic_s7-400_firmware *
siemens simatic_s7-400 -
siemens simatic_s7-1200_firmware *
siemens simatic_s7-1200 -
siemens simatic_s7-1500_firmware *
siemens simatic_s7-1500 -
siemens simatic_s7-1500_software_controller_firmware *
siemens simatic_s7-1500_software_controller -
siemens simatic_winac_rtx_firmware *
siemens simatic_winac_rtx_firmware 2010
siemens simatic_winac_rtx -
siemens sirius_act_3su1_firmware *
siemens sirius_act_3su1 -
siemens sirius_soft_starter_3rw44_pn_firmware *
siemens sirius_soft_starter_3rw44_pn -
siemens sirius_motor_starter_m200d_profinet_firmware *
siemens sirius_motor_starter_m200d_profinet -
siemens simocode_pro_v_profinet_firmware *
siemens simocode_pro_v_profinet -
siemens sinamics_dcm_firmware *
siemens sinamics_dcm_firmware 1.4
siemens sinamics_dcm_firmware 1.4
siemens sinamics_dcm -
siemens sinamics_dcp_firmware *
siemens sinamics_dcp_firmware 1.2
siemens sinamics_dcp -
siemens sinamics_g110m_firmware *
siemens sinamics_g110m_firmware 4.7
siemens sinamics_g110m -
siemens sinamics_g120\(c\/p\/d\)_w._pn_firmware *
siemens sinamics_g120\(c\/p\/d\)_w._pn_firmware 4.7
siemens sinamics_g120\(c\/p\/d\)_w._pn -
siemens sinamics_g130_firmware *
siemens sinamics_g130_firmware 4.7
siemens sinamics_g130 -
siemens sinamics_g150_firmware *
siemens sinamics_g150_firmware 4.7
siemens sinamics_g150 -
siemens sinamics__s110_pn_firmware *
siemens sinamics__s110_pn_firmware 4.4
siemens _s110_pn -
siemens sinamics_s120_firmware *
siemens sinamics_s120_firmware 4.7
siemens sinamics_s120 -
siemens sinamics_s150_firmware *
siemens sinamics_s150_firmware 4.7
siemens sinamics_s150 -
siemens sinamics_v90_pn_firmware *
siemens sinamics_v90_pn -
siemens simotion_firmware *
siemens simotion_firmware 4.5
siemens simotion -
siemens sinumerik_828d_firmware *
siemens sinumerik_828d_firmware 4.5
siemens sinumerik_828d -
siemens sinumerik_840d_sl_firmware *
siemens sinumerik_840d_sl_firmware 4.5
siemens sinumerik_840d_sl -
siemens simatic_hmi_comfort_panels *
siemens simatic_hmi_comfort_panels -
siemens simatic_hmi_multi_panels *
siemens simatic_hmi_multi_panels -
siemens simatic_hmi_mobile_panels *
siemens simatic_hmi_mobile_panels -
siemens simatic_cp_1243-1_irc_firmware *
siemens simatic_cp_1243-1_irc -
siemens simatic_cp_1243-1_iec_firmware *
siemens simatic_cp_1243-1_iec -
siemens simatic_cp_1243-1_dnp3_firmware *
siemens simatic_cp_1243-1_dnp3 -
siemens simatic_dk-1604_pn_io_firmware *
siemens simatic_dk-1604_pn_io -
siemens simatic_tdc_cpu555_firmware *
siemens simatic_tdc_cpu555 -
siemens simatic_tdc_cp51m1_firmware *
siemens simatic_tdc_cp51m1 -
siemens sinamics_gh150_firmware *
siemens sinamics_gh150_firmware 4.7
siemens sinamics_gh150 -
siemens sinamics_gl150_firmware *
siemens sinamics_gl150_firmware 4.8
siemens sinamics_gl150 -
siemens sinamics_gm150_firmware *
siemens sinamics_gm150_firmware 4.7
siemens sinamics_gm150 -
siemens sinamics_sl150_firmware *
siemens sinamics_sl150_firmware 4.8
siemens sinamics_sl150 -
siemens sinamics_sm120_firmware *
siemens sinamics_sm120_firmware 4.8
siemens sinamics_sm120 -
siemens extension_unit_12_profinet_firmware *
siemens extension_unit_12_profinet -
siemens extension_unit_15_profinet_firmware *
siemens extension_unit_15_profinet -
siemens extension_unit_19_profinet_firmware *
siemens extension_unit_19_profinet -
siemens extension_unit_22_profinet_firmware *
siemens extension_unit_22_profinet -
siemens simatic_cp_1242-7_gprs_firmware *
siemens simatic_cp_1242-7_gprs -
siemens simatic_cp_1243-7_lte\/us_firmware *
siemens simatic_cp_1243-7_lte\/us -
siemens simatic_cp_1243-8_firmware *
siemens simatic_cp_1243-8 -
siemens simatic_cp_1626_firmware *
siemens simatic_cp_1626 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_343-1_std_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CFF143FA-311E-4081-805F-BBDB72003556",
              "versionEndExcluding": "3.1.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_343-1_std:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9C351559-6D8D-4EA8-87D6-83003844BD97",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_343-1_lean_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "47A5C59B-DAB3-4B05-B9FA-B75685F4AE2A",
              "versionEndExcluding": "3.1.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_343-1_lean:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE2A18E2-F88F-4DC1-81E9-AC836C85A248",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_343-1_adv_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E0622A2-C918-4062-938A-8736469F8286",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_343-1_adv:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "438184C5-3A2C-4DEE-8FF2-0EFBAA1BA37A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_443-1_std_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BB8BECDB-D55A-4B74-ADEC-CDDBAC4E3481",
              "versionEndExcluding": "3.2.17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_443-1_std:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BB8C873A-25EB-4787-9F25-DC5852337093",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_443-1_adv_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "58E4035F-02AB-4B6D-A9AF-556DBE021C30",
              "versionEndExcluding": "3.2.17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_443-1_adv:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "75013961-5B00-42E9-9061-CF2E9A4FC090",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_443-1_opc-ua_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "32DC8BB2-9BC6-4CC2-9CF0-28DF8AEC595A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_443-1_opc-ua:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "977E97C8-959F-4146-8BFD-0FCF014B1534",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EBE1A019-4BC4-4352-BA16-05629A20F89F",
              "versionEndExcluding": "2.1.82",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA9BB25C-D5E3-43DE-8C73-06BDC43CA960",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cm_1542-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6BE0A3E5-0069-4AD5-B287-88BE5D0291F1",
              "versionEndExcluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cm_1542-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FCB3A00F-252F-4E41-8254-6E8BBD40C4FD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1542sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "18B597C8-0401-458F-8DF9-062B5E833115",
              "versionEndExcluding": "1.0.15",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1542sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C868560-8BAE-462D-AED0-3C52EA9B6DB8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A6AF0B55-84D1-46FA-B3A1-81EB2E2FED18",
              "versionEndExcluding": "1.0.15",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E362CEA5-F47B-4294-8F2D-A0A7AC6FF390",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA3E3782-7F36-4BC3-8D00-E1961E3105E3",
              "versionEndExcluding": "1.0.15",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1543sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "843A8686-5172-4782-BB97-B5D3C6FB27A3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1543-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "807D97E1-7680-4B8F-85AD-F56F039669D1",
              "versionEndExcluding": "2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1543-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3FDE92FB-38C7-46E8-9208-BBD7872219D5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf650r_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "37B4E3A9-FE27-4A31-A213-92B461A5C846",
              "versionEndExcluding": "3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf650r:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C82C2C69-D983-4317-968B-D1855DF8AE43",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf680r_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "177A6E55-8D64-4CB8-B366-AE272E715932",
              "versionEndExcluding": "3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf680r:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "450DE127-DFED-4799-B8EA-0F95028E4BC3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf685r_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "72D14DB5-6132-4442-8AB2-3ECE89B1D47C",
              "versionEndExcluding": "3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf685r:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "63F70060-0090-4BD7-8BF6-769989879ACD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1616_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4FDC53A8-3F99-481E-9B0A-F5AF296B5BD6",
              "versionEndExcluding": "2.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1616:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA074FBE-1C3E-4441-8C51-52B555B85D9F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1604_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0424AECD-68D5-45F1-9F55-B72CB4DFE39C",
              "versionEndExcluding": "2.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1604:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6304FA24-F194-4EE2-95F5-35D086F82C01",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_dk-1616_pn_io_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "39663B8F-F349-49B3-A0CB-004F11D01E34",
              "versionEndExcluding": "2.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_dk-1616_pn_io:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C8F515DF-36AC-49C1-B013-E87529775AB3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "45008AE8-8386-4CBA-8C38-10C1A60150C2",
              "versionEndExcluding": "5.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A59C91EA-5D1B-4970-8C36-BD76BA420B12",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x200_irt_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F61995A-2018-4DAA-9529-BADC145B267F",
              "versionEndExcluding": "5.4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x200_irt:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CAF3DA7A-6B80-4F20-835F-BF071197D1B0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x300_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC97A506-7E63-43A3-ACB0-DDAF3C5369C3",
              "versionEndExcluding": "4.1.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x300:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E3F6299B-D7E3-4750-B016-7DCBC83C2287",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x408_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B8A4CF89-9DDA-4974-A886-CC0A912017F7",
              "versionEndExcluding": "4.1.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x408:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "47F713E4-4B75-476E-BC21-92CA10198AE9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x414_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2CA7C987-779A-4B64-BFAC-73D54618AF04",
              "versionEndExcluding": "3.10.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x414:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E4C1BEF-D6B4-4260-9AC5-6F903EF6F4B1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm400_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F6EB11E9-4036-4A93-91DC-4D987B5FE2BA",
              "versionEndExcluding": "6.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm400:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9FC408A8-903F-43A2-9D05-65AD4482FDBB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr500_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B9AF696-211F-4CAD-8A0E-402487E8DC50",
              "versionEndExcluding": "6.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "080E722F-FCD4-4967-86EE-151ADC5702E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w700_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8763BB9-5DDA-4817-BDA6-63983CD4BC67",
              "versionEndExcluding": "6.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w700:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D3033B1E-57A6-4AE3-A861-7047CF8EAD79",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B74BBB98-0146-467E-B77B-E2FA1ABF2ED5",
              "versionEndExcluding": "4.03",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFB9921A-5204-40A3-88AB-B7755F5C6875",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2345F75-2CD1-4014-8F90-36A4FB4CC3BE",
              "versionEndExcluding": "4.03",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E917CBBB-EF41-4113-B0CA-EB91889235E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:softnet_profinet_io_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9831567D-6528-4ACA-99F9-1EC42CB4A90D",
              "versionEndExcluding": "14",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:softnet_profinet_io_firmware:14:-:*:*:*:*:*:*",
              "matchCriteriaId": "27BC04E4-8C6F-4A66-86C4-A8F793A10BDD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:softnet_profinet_io:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E348069A-B809-4DF6-81E9-DC52C6E2C268",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ie\\/pb-link_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8ED91175-0AF3-424A-8C49-43587BB95EAB",
              "versionEndExcluding": "3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ie\\/pb-link:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8D43C16C-0719-4648-903F-6CC0FFF1835A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ie\\/as-i_link_pn_io_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E909C1E-9329-4459-ACE3-AD906CD4A968",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ie\\/as-i_link_pn_io:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "317863B6-0B71-4D03-83FE-FC59EBB5307C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_standard_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5C887573-8BE8-42CF-B35A-22F9311AC627",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_standard:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3A5A3F7E-D039-430F-89B0-6AB4FD2428D4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_basic_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "80D166A8-1EEC-42F4-8EAB-1747247A7A05",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_basic:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FFA520B6-5177-43E4-87C0-C215F79FE9B4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_advanced_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C8E76BDE-C7E9-4D6B-B5D9-A456516CD016",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_advanced_modem:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BF513598-C3FA-4555-8133-A7276DDAFAC8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sitop_psu8600_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5468C9FA-ADD9-4FD3-89FE-C3621F5CB0EC",
              "versionEndExcluding": "1.2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sitop_psu8600:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "55058209-8AE5-42AF-80D4-5A7A44307266",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ups1600_profinet_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "54B85DBA-24CA-4F95-89A5-D53D5AC69B0E",
              "versionEndExcluding": "2.2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ups1600_profinet:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ECC84D6F-F5E0-47CF-B11E-1C43F866D972",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200al_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C9D0595-53CD-48C0-82E3-DB0B2EC17721",
              "versionEndExcluding": "1.0.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200al:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "34C17B00-34B5-4A15-9333-252BE2975F37",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200ecopn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3EE0B998-E408-408F-8F78-5E90F74E9C9B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200ecopn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0259EAE9-0CA0-49A5-A573-8339604A181B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200m_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "14E56570-5C20-40BD-BF0B-F6ED06AFC8F7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200m:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7037E46B-4FE5-4693-B6A6-B5AF7B652C4F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200mp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "55BE63B0-F44E-4FCD-B00C-77595BACC62E",
              "versionEndExcluding": "4.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200mp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "49DA8715-D671-4D8F-A870-E61960A5AFA4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200pro_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D054139B-BE36-4B34-88AE-BC487DCB1DCB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200pro:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F0CE2EC-9A73-4576-A389-A19893D47B0F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200s_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BB063929-AAB0-4FF8-BCA3-71BA80517B1A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1EC40E7-F004-446C-B5C9-0AB9911105E0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E6BACBC9-7C60-4A41-B8C6-A5E46B568029",
              "versionEndExcluding": "4.1.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200sp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "691CA334-4394-4ED6-B417-F67FC92228AE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:pn\\/pn_coupler_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "32BD232D-A6BB-4D7B-BD00-1085D08D8A77",
              "versionEndExcluding": "4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:pn\\/pn_coupler:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB2846BD-9DAB-44A2-87C9-39E3ACFE03FA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0FE40195-DE5A-4B9C-9455-FAF92FF090D0",
              "versionEndExcluding": "4.1.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:4.1.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "9B339839-3D74-4E13-9EB6-24CA46F991A5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:dk_standard_ethernet_controller:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "53DF35F1-94FF-4D0B-9FA2-E8B0AFAEA5FF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ek-ertec_200p_pn_io_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9329BF4-D00A-4138-AA4C-93022002C0B9",
              "versionEndExcluding": "4.4.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:ek-ertec_200p_pn_io_firmware:4.4.0:-:*:*:*:*:*:*",
              "matchCriteriaId": "7863DDDC-D5CE-44FE-89C4-0E8A702A91A8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ek-ertec_200p_pn_io:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E62802E3-AFA3-4023-9671-95C220397956",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ek-ertec_200_pn_io_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8C46E084-9732-4920-86C2-3A91830CBCE3",
              "versionEndExcluding": "4.2.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:ek-ertec_200_pn_io_firmware:4.2.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "18C8B2FB-87C3-4DBB-9960-53FA545F26CB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ek-ertec_200_pn_io:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "42D3FAF4-9B78-4EEF-8D80-17E9B98228D2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-200_smart_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "251EE4B2-F1C7-4ACF-B90D-4C0FE3D181E5",
              "versionEndExcluding": "2.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-200_smart:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "598EEFC9-5240-4011-9017-A9557585AA19",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-300_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4C096137-C1E3-4D19-87A9-BEB7A081DD1E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-300:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7EFD4E99-5C66-443F-8B6F-FA01C895DE78",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-400_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2570E321-C28E-46FA-8693-1230B3B5FD1B",
              "versionEndExcluding": "6.0.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-400:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F97B67B-4516-4AD9-B33C-7F480EE0DB4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "582B49BD-4565-4D19-BBE6-A193BDFCE8B0",
              "versionEndExcluding": "4.2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EC545350-FD53-4B2E-886F-E20F12260C9B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D24953B-B3DF-4150-810C-64A94A55E829",
              "versionEndExcluding": "2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "30DDEA9B-E1BF-4572-8E12-D13C54603E77",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_software_controller_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E696D071-8601-40AA-BAF5-1452940E1D6E",
              "versionEndExcluding": "2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_software_controller:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE4D4D21-9868-4FA3-89A8-1EEC473383EF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "80BDBB38-20D2-48C3-8B58-62C2D8CC00B8",
              "versionEndExcluding": "2010",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:2010:-:*:*:*:*:*:*",
              "matchCriteriaId": "EA59D713-F342-4CDA-BDC8-108352D385DA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_winac_rtx:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA5ADAB0-3985-4933-8CDD-D1546D8271CC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sirius_act_3su1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E36412A-1AAB-42D1-B0B4-7A7BBF3CB317",
              "versionEndExcluding": "1.1.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sirius_act_3su1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8582A3E8-C05E-4D0B-851D-8C3181ED61CC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sirius_soft_starter_3rw44_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F84A65E6-4672-4B62-826E-6FAAE0B4A89D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sirius_soft_starter_3rw44_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBB058FA-3E70-4489-AAB1-0CB7EF16A2E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sirius_motor_starter_m200d_profinet_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3D42184E-8998-4C40-9612-5C9DE193CC06",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sirius_motor_starter_m200d_profinet:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BA5CB62E-04B7-4DD3-AA06-EB4A4FA58E54",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simocode_pro_v_profinet_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "98FDB53A-8F5D-46AA-9366-F6480B12D744",
              "versionEndExcluding": "2.0.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simocode_pro_v_profinet:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "352651A0-F7CE-4689-8597-15F3764707A9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_dcm_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FD2943F3-C46C-462E-9062-EE7B3E56CF72",
              "versionEndExcluding": "1.4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_dcm_firmware:1.4:-:*:*:*:*:*:*",
              "matchCriteriaId": "975EFBBB-33E1-4D04-9E06-93553D45539C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_dcm_firmware:1.4:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "99A0D811-2751-420E-AD85-B6EC777C8CAE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1A43D34-ECA3-4330-B85F-02BDD1D22149",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_dcp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D7A7140-62A2-434F-AB79-1D47C918F1FE",
              "versionEndExcluding": "1.2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_dcp_firmware:1.2:-:*:*:*:*:*:*",
              "matchCriteriaId": "A2B61A79-C2B0-4C3D-A63C-B20FF78B2981",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B75F50CA-7371-4BC7-8D8A-13F8BC69E4EB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g110m_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "775C90BB-C026-435C-889A-517EF85656C5",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g110m_firmware:4.7:-:*:*:*:*:*:*",
              "matchCriteriaId": "CAA92AC6-7DA0-418D-A13F-69268DFD7966",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D61D3E9C-1346-4354-BCD9-B02F67500C41",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g120\\(c\\/p\\/d\\)_w._pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "413AA7BE-CFE1-49DB-965F-1BD50D61F82F",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g120\\(c\\/p\\/d\\)_w._pn_firmware:4.7:-:*:*:*:*:*:*",
              "matchCriteriaId": "82B4BE4B-3AE5-4039-B18D-A5DE3F1DDEF8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_g120\\(c\\/p\\/d\\)_w._pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0EE820D5-16B2-4565-9D83-AF018C08B5E5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g130_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B3B0706-47CD-43FB-8E3A-7EEEF020AFBA",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g130_firmware:4.7:-:*:*:*:*:*:*",
              "matchCriteriaId": "1D36CF8D-6DA4-49ED-9EF1-F96292F671EE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "373DBE44-AC28-4D04-93BB-35CD8C60E899",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g150_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AC731378-CB83-4C15-BC6A-5A86DF9B62F1",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g150_firmware:4.7:-:*:*:*:*:*:*",
              "matchCriteriaId": "51A78A0B-5D75-418A-98AC-6EBF50D89A8A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2296CA65-0E89-4BCB-8003-E7212BF1F585",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics__s110_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7143613F-4627-4F62-8F1B-E64CCB20F3D1",
              "versionEndExcluding": "4.4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics__s110_pn_firmware:4.4:-:*:*:*:*:*:*",
              "matchCriteriaId": "B428560B-2CAC-4A63-B677-724D95E12023",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:_s110_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "23B97849-01A7-4A8F-84DD-D25CF84D010B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "77A0BE57-1A9A-4564-9C53-CF47DEEF7991",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:4.7:-:*:*:*:*:*:*",
              "matchCriteriaId": "376556D0-1AE2-4F80-B3CE-C0251E35C326",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5A824BD-935F-4E53-8313-C5544B0489C7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s150_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "772FF972-2193-4639-B454-F92762E49C39",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s150_firmware:4.7:-:*:*:*:*:*:*",
              "matchCriteriaId": "EE2B31F0-D45F-4B42-95D2-540C68C5F3DE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_s150:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D48682C-A39D-4A09-B904-50FA64A9D2A5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_v90_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8EE54303-4FDA-42C7-B33B-BA884CD31339",
              "versionEndExcluding": "1.01",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_v90_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D870F289-F2BC-4105-A8F0-30E47CDE9FEF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simotion_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "92A7198A-D6C5-4FBF-8860-5C8EA864718B",
              "versionEndExcluding": "4.5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simotion_firmware:4.5:-:*:*:*:*:*:*",
              "matchCriteriaId": "B5DA6BF7-ECB8-47F1-A791-E65CFF89A608",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simotion:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "879CF09E-4735-4A73-8E7B-215F2701F7E0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_828d_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "71CD07D8-ECED-47EF-B2BC-0585F9BB00C1",
              "versionEndExcluding": "4.5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_828d_firmware:4.5:-:*:*:*:*:*:*",
              "matchCriteriaId": "AEB948AA-7BD7-4A0F-B86E-38ECD722C086",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinumerik_828d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7D97047C-9772-4AEB-B993-131EBBAE33BA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "28E3AB24-86B4-485D-8D3A-131E5C7F0108",
              "versionEndExcluding": "4.5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:4.5:-:*:*:*:*:*:*",
              "matchCriteriaId": "40AC387B-B799-4A34-8C9E-73D05B86801D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "765286DF-07EC-4C7A-AB8C-09559CD977EA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CE53BC8E-CDA7-476A-87CA-532F365C79A7",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BCFE761-35C9-43EF-85BC-E8083B9F75CB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_multi_panels:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1150AED-CDBE-492C-95FF-3E02B3B447F1",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_multi_panels:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1AAE6A83-737B-47A9-86BB-652C7F6A8013",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_mobile_panels:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "42E8D21B-9CF4-4C2E-B33C-212BA29C7124",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_mobile_panels:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "55E03180-BE77-4A22-A6C1-FE90B9760570",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "02610368-4B97-4B3F-8592-64CF8F65D8AD",
              "versionEndExcluding": "2.1.82",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "61E7964A-E7A4-4CDE-B376-5BBEC5F00A73",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_iec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BE5003DA-5488-47C1-B442-9137E849FDD5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1_iec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFE96226-A2DF-4A9E-8CBB-8D7CF328E404",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_dnp3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FCF9D803-FF47-4400-B2C4-1F4EE28E5AA8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FFBFB96-1A35-4724-831B-68E3A9C32921",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_dk-1604_pn_io_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "65EDC583-1BCE-4787-820F-39DBD280DADF",
              "versionEndExcluding": "2.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_dk-1604_pn_io:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "568ED124-AEE8-4BDC-BB89-0F8F83BA7537",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D87643C3-6525-4CBD-BC0C-6B4DC30C8642",
              "versionEndExcluding": "1.1.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_tdc_cpu555:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE6AB995-D67B-43E5-B8FF-97C38D20CB10",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5C936A7A-1AF9-44E4-9CEC-0694A424616B",
              "versionEndExcluding": "1.1.8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_tdc_cp51m1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8DA1E7C4-6352-41A4-8A94-C24DDB456572",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D3F052D2-B537-4BF9-AF05-60107FDE0BEA",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_gh150_firmware:4.7:-:*:*:*:*:*:*",
              "matchCriteriaId": "96C7E194-617D-4593-B544-10AEFF59CCA5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BF977545-395A-4C34-BB22-A1047B5B6E85",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3653DA37-DB23-41E0-8CE8-838E384AA40A",
              "versionEndExcluding": "4.8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:4.8:-:*:*:*:*:*:*",
              "matchCriteriaId": "0F86A334-10F9-4DFB-A421-CBCAFD86C8C2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DED7F33B-D475-4232-8683-48554A6729F7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1BF93390-E65B-434E-9891-271DF7D11F47",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:4.7:-:*:*:*:*:*:*",
              "matchCriteriaId": "55F6B737-7237-4D38-A0F0-9EFCE76DC9C4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FD67D30A-8681-41AE-B248-7E50BA1B9FC8",
              "versionEndExcluding": "4.8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:4.8:-:*:*:*:*:*:*",
              "matchCriteriaId": "FCC0EE8B-1088-46B6-992A-B8E12A7B7DC2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C6619B0F-7CDC-40A6-89B2-C6067AF45214",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "31393A1B-4DBC-476D-875E-463B4B887E1B",
              "versionEndExcluding": "4.8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_sm120_firmware:4.8:-:*:*:*:*:*:*",
              "matchCriteriaId": "0206F9F2-27C7-4D2F-817B-13F8FA31E547",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "444DD77F-DB65-4766-A89D-7A679B4CA1E1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:extension_unit_12_profinet_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E789146F-1FA4-42E4-B867-FD0F5A7316CA",
              "versionEndExcluding": "01.01.01",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:extension_unit_12_profinet:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E0B32CC-8268-4B38-BBC7-51154882EC82",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:extension_unit_15_profinet_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "05B55989-A3E9-4AA1-A619-C75FEAA0B5DA",
              "versionEndExcluding": "01.01.01",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:extension_unit_15_profinet:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA05435D-9A52-4D43-BE74-7D4C6C156AC6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:extension_unit_19_profinet_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "52156691-1368-4C77-98A7-EA63089091C5",
              "versionEndExcluding": "01.01.01",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:extension_unit_19_profinet:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5EE8B9B8-3C49-4296-9BC0-7E030878D479",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:extension_unit_22_profinet_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EC052323-2E00-415D-847A-66F77AD5C3FD",
              "versionEndExcluding": "01.01.01",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:extension_unit_22_profinet:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F884CAF-D152-4318-B49B-0D68936D2BD9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1242-7_gprs_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4E035CB-0F76-47C0-B2C7-93AFA8A7B38B",
              "versionEndExcluding": "2.1.82",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1242-7_gprs:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C6AEC7D6-7E5E-4CFF-99C8-7FBADA2479D5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-7_lte\\/us_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E4CEE93A-9641-424B-AF55-2C550CA568F2",
              "versionEndExcluding": "2.1.82",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-7_lte\\/us:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "00DDA679-D761-4986-A0A0-4C00178DF0B5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-8_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7D21A891-321B-42A3-8173-8E0743AEDD65",
              "versionEndExcluding": "2.1.82",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-8:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE0116F3-67FA-4129-B1FF-023774D179AF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1626_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "71BAF32C-35EA-4704-B75D-9EED01F8264B",
              "versionEndExcluding": "1.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1626:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "581EA284-EDD6-4EA5-96B2-67904D1D9DC7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected."
    },
    {
      "lang": "es",
      "value": "Los paquetes de difusi\u00f3n PROFINET DCP especialmente elaborados podr\u00edan causar una condici\u00f3n de denegaci\u00f3n de servicio de los productos afectados en un segmento Ethernet local (capa 2). Se requiere la interacci\u00f3n humana para recuperar los sistemas. Las interfaces PROFIBUS no est\u00e1n afectadas"
    }
  ],
  "id": "CVE-2017-2680",
  "lastModified": "2025-04-20T01:37:25.860",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "ADJACENT_NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 6.1,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 6.5,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "[email protected]",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "[email protected]",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "[email protected]",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "ADJACENT",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 7.1,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "NONE",
          "vulnIntegrityImpact": "NONE",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "[email protected]",
        "type": "Secondary"
      }
    ]
  },
  "published": "2017-05-11T01:29:05.400",
  "references": [
    {
      "source": "[email protected]",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/98369"
    },
    {
      "source": "[email protected]",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securitytracker.com/id/1038463"
    },
    {
      "source": "[email protected]",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-284673.html"
    },
    {
      "source": "[email protected]",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html"
    },
    {
      "source": "[email protected]",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html"
    },
    {
      "source": "[email protected]",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf"
    },
    {
      "source": "[email protected]",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
    },
    {
      "source": "[email protected]",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf"
    },
    {
      "source": "[email protected]",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02"
    },
    {
      "source": "[email protected]",
      "tags": [
        "Broken Link"
      ],
      "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/98369"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securitytracker.com/id/1038463"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-284673.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Broken Link"
      ],
      "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf"
    }
  ],
  "sourceIdentifier": "[email protected]",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-400"
        }
      ],
      "source": "[email protected]",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-400"
        }
      ],
      "source": "[email protected]",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2017-05-11 10:29
Modified
2025-04-20 01:37
Summary
Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.
Impacted products
Vendor Product Version
siemens simatic_cp_343-1_std_firmware *
siemens simatic_cp_343-1_std -
siemens simatic_cp_343-1_lean_firmware *
siemens simatic_cp_343-1_lean -
siemens simatic_cp_343-1_adv_firmware *
siemens simatic_cp_343-1_adv -
siemens simatic_cp_443-1_std_firmware *
siemens simatic_cp_443-1_std -
siemens simatic_cp_443-1_adv_firmware *
siemens simatic_cp_443-1_adv -
siemens simatic_cp_443-1_opc-ua_firmware *
siemens simatic_cp_443-1_opc-ua -
siemens simatic_cp_1243-1_firmware *
siemens simatic_cp_1243-1 -
siemens simatic_cm_1542-1_firmware *
siemens simatic_cm_1542-1 -
siemens simatic_cp_1543sp-1_firmware *
siemens simatic_cp_1542sp-1 -
siemens simatic_cp_1542sp-1_irc_firmware *
siemens simatic_cp_1542sp-1_irc -
siemens simatic_cp_1543sp-1_firmware *
siemens simatic_cp_1543sp-1 -
siemens simatic_cp_1543-1_firmware *
siemens simatic_cp_1543-1 -
siemens simatic_rf650r_firmware *
siemens simatic_rf650r -
siemens simatic_rf680r_firmware *
siemens simatic_rf680r -
siemens simatic_rf685r_firmware *
siemens simatic_rf685r -
siemens simatic_cp_1616_firmware *
siemens simatic_cp_1616 -
siemens simatic_cp_1604_firmware *
siemens simatic_cp_1604 -
siemens simatic_dk-16xx_pn_io_firmware *
siemens simatic_dk-16xx_pn_io -
siemens scalance_x200_firmware *
siemens scalance_x200 -
siemens scalance_x200_irt_firmware *
siemens scalance_x200_irt -
siemens scalance_x300_firmware *
siemens scalance_x300 -
siemens scalance_x408_firmware *
siemens scalance_x408 -
siemens scalance_x414_firmware *
siemens scalance_x414 -
siemens scalance_xm400_firmware *
siemens scalance_xm400 -
siemens scalance_xr500_firmware *
siemens scalance_xr500 -
siemens scalance_w700_firmware *
siemens scalance_w700 -
siemens scalance_m-800_firmware *
siemens scalance_m-800 -
siemens scalance_s615_firmware *
siemens scalance_s615 -
siemens softnet_profinet_io_firmware *
siemens softnet_profinet_io_firmware 14
siemens softnet_profinet_io -
siemens ie\/pb-link_firmware *
siemens ie\/pb-link -
siemens ie\/as-i_link_pn_io_firmware *
siemens ie\/as-i_link_pn_io -
siemens simatic_teleservice_adapter_standard_modem_firmware *
siemens simatic_teleservice_adapter_standard_modem -
siemens simatic_teleservice_adapter_ie_basic_modem_firmware *
siemens simatic_teleservice_adapter_ie_basic_modem -
siemens simatic_teleservice_adapter_ie_advanced_modem_firmware *
siemens simatic_teleservice_adapter_ie_advanced_modem -
siemens sitop_psu8600_firmware *
siemens sitop_psu8600 -
siemens ups1600_profinet_firmware *
siemens ups1600_profinet -
siemens simatic_et_200al_firmware *
siemens simatic_et_200al -
siemens simatic_et_200ecopn_firmware *
siemens simatic_et_200ecopn -
siemens simatic_et_200m_firmware *
siemens simatic_et_200m -
siemens simatic_et_200mp_firmware *
siemens simatic_et_200mp -
siemens simatic_et_200pro_firmware *
siemens simatic_et_200pro -
siemens simatic_et_200s_firmware *
siemens simatic_et_200s -
siemens simatic_et_200sp_firmware *
siemens simatic_et_200sp -
siemens pn\/pn_coupler_firmware *
siemens pn\/pn_coupler -
siemens dk_standard_ethernet_controller_firmware *
siemens dk_standard_ethernet_controller_firmware 4.1.1
siemens dk_standard_ethernet_controller -
siemens ek-ertec_200p_pn_io_firmware *
siemens ek-ertec_200p_pn_io_firmware 4.4.0
siemens ek-ertec_200p_pn_io -
siemens ek-ertec_200_pn_io_firmware *
siemens ek-ertec_200_pn_io_firmware 4.2.1
siemens ek-ertec_200_pn_io -
siemens simatic_s7-200_smart_firmware *
siemens simatic_s7-200_smart -
siemens simatic_s7-300_firmware *
siemens simatic_s7-300 -
siemens simatic_s7-400_firmware *
siemens simatic_s7-400 -
siemens simatic_s7-1200_firmware *
siemens simatic_s7-1200 -
siemens simatic_s7-1500_firmware *
siemens simatic_s7-1500 -
siemens simatic_winac_rtx_firmware *
siemens simatic_winac_rtx_firmware 2010
siemens simatic_winac_rtx -
siemens sirius_act_3su1_firmware *
siemens sirius_act_3su1 -
siemens sirius_soft_starter_3rw44_pn_firmware *
siemens sirius_soft_starter_3rw44_pn -
siemens sirius_motor_starter_m200d_profinet_firmware *
siemens sirius_motor_starter_m200d_profinet -
siemens simocode_pro_v_profinet_firmware *
siemens simocode_pro_v_profinet -
siemens sinamics_dcm_firmware *
siemens sinamics_dcm_firmware 1.4
siemens sinamics_dcm -
siemens sinamics_dcp_firmware *
siemens sinamics_dcp_firmware 1.2
siemens sinamics_dcp -
siemens sinamics_g110m_firmware *
siemens sinamics_g110m_firmware 4.7
siemens sinamics_g110m -
siemens sinamics_g120\(c\/p\/d\)_pn_firmware *
siemens sinamics_g120\(c\/p\/d\)_pn -
siemens sinamics_g130_firmware *
siemens sinamics_g130_firmware 4.7
siemens sinamics_g130 -
siemens sinamics_g150_firmware *
siemens sinamics_g150_firmware 4.7
siemens sinamics_g150 -
siemens sinamics_s110_pn_firmware *
siemens sinamics_s110_pn_firmware 4.4
siemens sinamics_s110_pn -
siemens sinamics_s120_firmware *
siemens sinamics_s120_firmware 4.7
siemens sinamics_s120 -
siemens sinamics_s150_firmware *
siemens sinamics_s150_firmware 4.7
siemens sinamics_s150 -
siemens sinamics_v90_pn_firmware *
siemens sinamics_v90_pn -
siemens simotion_firmware *
siemens simotion_firmware 4.5
siemens simotion -
siemens sinumerik_828d_firmware *
siemens sinumerik_828d_firmware 4.5
siemens sinumerik_828d -
siemens sinumerik_840d_sl_firmware *
siemens sinumerik_840d_sl_firmware 4.5
siemens sinumerik_840d_sl -
siemens simatic_hmi_comfort_panels *
siemens simatic_hmi_comfort_panels -
siemens simatic_hmi_multi_panels *
siemens simatic_hmi_multi_panels -
siemens simatic_hmi_mobile_panels *
siemens simatic_hmi_mobile_panels -
siemens simatic_cp_1243-1_irc_firmware *
siemens simatic_cp_1243-1_irc -
siemens simatic_cp_1243-1_iec_firmware *
siemens simatic_cp_1243-1_iec -
siemens simatic_cp_1243-1_dnp3_firmware *
siemens simatic_cp_1243-1_dnp3 -
siemens simatic_cm_1542sp-1_firmware *
siemens simatic_cm_1542sp-1 -
siemens simatic_s7-1500_software_controller *
siemens sinumerik_828d_firmware *
siemens sinumerik_828d_firmware 4.7
siemens sinumerik_828d -
siemens sinumerik_840d_sl_firmware *
siemens sinumerik_840d_sl_firmware 4.7
siemens sinumerik_840d_sl -
siemens simatic_tdc_cpu555_firmware *
siemens simatic_tdc_cpu555 -
siemens simatic_tdc_cp51m1_firmware *
siemens simatic_tdc_cp51m1 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_343-1_std_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CFF143FA-311E-4081-805F-BBDB72003556",
              "versionEndExcluding": "3.1.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_343-1_std:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9C351559-6D8D-4EA8-87D6-83003844BD97",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_343-1_lean_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "47A5C59B-DAB3-4B05-B9FA-B75685F4AE2A",
              "versionEndExcluding": "3.1.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_343-1_lean:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE2A18E2-F88F-4DC1-81E9-AC836C85A248",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_343-1_adv_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E0622A2-C918-4062-938A-8736469F8286",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_343-1_adv:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "438184C5-3A2C-4DEE-8FF2-0EFBAA1BA37A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_443-1_std_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BB8BECDB-D55A-4B74-ADEC-CDDBAC4E3481",
              "versionEndExcluding": "3.2.17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_443-1_std:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BB8C873A-25EB-4787-9F25-DC5852337093",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_443-1_adv_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "58E4035F-02AB-4B6D-A9AF-556DBE021C30",
              "versionEndExcluding": "3.2.17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_443-1_adv:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "75013961-5B00-42E9-9061-CF2E9A4FC090",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_443-1_opc-ua_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "32DC8BB2-9BC6-4CC2-9CF0-28DF8AEC595A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_443-1_opc-ua:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "977E97C8-959F-4146-8BFD-0FCF014B1534",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EBE1A019-4BC4-4352-BA16-05629A20F89F",
              "versionEndExcluding": "2.1.82",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA9BB25C-D5E3-43DE-8C73-06BDC43CA960",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cm_1542-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6BE0A3E5-0069-4AD5-B287-88BE5D0291F1",
              "versionEndExcluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cm_1542-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FCB3A00F-252F-4E41-8254-6E8BBD40C4FD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA3E3782-7F36-4BC3-8D00-E1961E3105E3",
              "versionEndExcluding": "1.0.15",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1542sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C868560-8BAE-462D-AED0-3C52EA9B6DB8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A6AF0B55-84D1-46FA-B3A1-81EB2E2FED18",
              "versionEndExcluding": "1.0.15",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E362CEA5-F47B-4294-8F2D-A0A7AC6FF390",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "496E9B17-BD29-4DE9-96B3-B23E3599C766",
              "versionEndExcluding": "2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1543sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "843A8686-5172-4782-BB97-B5D3C6FB27A3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1543-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "12F7A42E-4D63-4A2A-ABF6-CA08BB6C6234",
              "versionEndExcluding": "1.0.15",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1543-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3FDE92FB-38C7-46E8-9208-BBD7872219D5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf650r_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "37B4E3A9-FE27-4A31-A213-92B461A5C846",
              "versionEndExcluding": "3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf650r:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C82C2C69-D983-4317-968B-D1855DF8AE43",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf680r_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "177A6E55-8D64-4CB8-B366-AE272E715932",
              "versionEndExcluding": "3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf680r:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "450DE127-DFED-4799-B8EA-0F95028E4BC3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf685r_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "72D14DB5-6132-4442-8AB2-3ECE89B1D47C",
              "versionEndExcluding": "3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf685r:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "63F70060-0090-4BD7-8BF6-769989879ACD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1616_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4FDC53A8-3F99-481E-9B0A-F5AF296B5BD6",
              "versionEndExcluding": "2.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1616:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA074FBE-1C3E-4441-8C51-52B555B85D9F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1604_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0424AECD-68D5-45F1-9F55-B72CB4DFE39C",
              "versionEndExcluding": "2.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1604:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6304FA24-F194-4EE2-95F5-35D086F82C01",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_dk-16xx_pn_io_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "26113F2F-8C5E-471B-9E12-AA3B3860B5CF",
              "versionEndExcluding": "2.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_dk-16xx_pn_io:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA0D867D-737F-4CEC-BAEA-9ADE0BA2303E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "45008AE8-8386-4CBA-8C38-10C1A60150C2",
              "versionEndExcluding": "5.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A59C91EA-5D1B-4970-8C36-BD76BA420B12",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x200_irt_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F61995A-2018-4DAA-9529-BADC145B267F",
              "versionEndExcluding": "5.4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x200_irt:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CAF3DA7A-6B80-4F20-835F-BF071197D1B0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x300_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC97A506-7E63-43A3-ACB0-DDAF3C5369C3",
              "versionEndExcluding": "4.1.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x300:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E3F6299B-D7E3-4750-B016-7DCBC83C2287",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x408_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B8A4CF89-9DDA-4974-A886-CC0A912017F7",
              "versionEndExcluding": "4.1.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x408:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "47F713E4-4B75-476E-BC21-92CA10198AE9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x414_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2CA7C987-779A-4B64-BFAC-73D54618AF04",
              "versionEndExcluding": "3.10.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x414:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E4C1BEF-D6B4-4260-9AC5-6F903EF6F4B1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm400_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F6EB11E9-4036-4A93-91DC-4D987B5FE2BA",
              "versionEndExcluding": "6.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm400:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9FC408A8-903F-43A2-9D05-65AD4482FDBB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr500_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B9AF696-211F-4CAD-8A0E-402487E8DC50",
              "versionEndExcluding": "6.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "080E722F-FCD4-4967-86EE-151ADC5702E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w700_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8763BB9-5DDA-4817-BDA6-63983CD4BC67",
              "versionEndExcluding": "6.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w700:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D3033B1E-57A6-4AE3-A861-7047CF8EAD79",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B74BBB98-0146-467E-B77B-E2FA1ABF2ED5",
              "versionEndExcluding": "4.03",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFB9921A-5204-40A3-88AB-B7755F5C6875",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2345F75-2CD1-4014-8F90-36A4FB4CC3BE",
              "versionEndExcluding": "4.03",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E917CBBB-EF41-4113-B0CA-EB91889235E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:softnet_profinet_io_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9831567D-6528-4ACA-99F9-1EC42CB4A90D",
              "versionEndExcluding": "14",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:softnet_profinet_io_firmware:14:-:*:*:*:*:*:*",
              "matchCriteriaId": "27BC04E4-8C6F-4A66-86C4-A8F793A10BDD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:softnet_profinet_io:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E348069A-B809-4DF6-81E9-DC52C6E2C268",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ie\\/pb-link_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8ED91175-0AF3-424A-8C49-43587BB95EAB",
              "versionEndExcluding": "3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ie\\/pb-link:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8D43C16C-0719-4648-903F-6CC0FFF1835A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ie\\/as-i_link_pn_io_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E909C1E-9329-4459-ACE3-AD906CD4A968",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ie\\/as-i_link_pn_io:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "317863B6-0B71-4D03-83FE-FC59EBB5307C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_teleservice_adapter_standard_modem_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A9F37323-B072-470B-B770-9735B84CACFE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_teleservice_adapter_standard_modem:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "610DF0CA-D0FA-4CBE-8383-6F038E7AC4C3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_basic_modem_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B366E4A-4223-4A42-9A05-52EB23BCF209",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_basic_modem:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "98FB86B6-DB8A-42EF-BA60-68D96B6FE8B6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_advanced_modem_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7CD7CAEE-9C1A-4520-8F85-FD9BFB0A57D9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_advanced_modem:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BF513598-C3FA-4555-8133-A7276DDAFAC8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sitop_psu8600_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5468C9FA-ADD9-4FD3-89FE-C3621F5CB0EC",
              "versionEndExcluding": "1.2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sitop_psu8600:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "55058209-8AE5-42AF-80D4-5A7A44307266",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ups1600_profinet_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "54B85DBA-24CA-4F95-89A5-D53D5AC69B0E",
              "versionEndExcluding": "2.2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ups1600_profinet:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ECC84D6F-F5E0-47CF-B11E-1C43F866D972",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200al_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C9D0595-53CD-48C0-82E3-DB0B2EC17721",
              "versionEndExcluding": "1.0.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200al:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "34C17B00-34B5-4A15-9333-252BE2975F37",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200ecopn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3EE0B998-E408-408F-8F78-5E90F74E9C9B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200ecopn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0259EAE9-0CA0-49A5-A573-8339604A181B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200m_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "14E56570-5C20-40BD-BF0B-F6ED06AFC8F7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200m:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7037E46B-4FE5-4693-B6A6-B5AF7B652C4F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200mp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "55BE63B0-F44E-4FCD-B00C-77595BACC62E",
              "versionEndExcluding": "4.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200mp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "49DA8715-D671-4D8F-A870-E61960A5AFA4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200pro_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D054139B-BE36-4B34-88AE-BC487DCB1DCB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200pro:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F0CE2EC-9A73-4576-A389-A19893D47B0F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200s_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BB063929-AAB0-4FF8-BCA3-71BA80517B1A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1EC40E7-F004-446C-B5C9-0AB9911105E0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3237684A-3BEA-462F-A91D-ABC94C90D15A",
              "versionEndExcluding": "4.2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200sp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "691CA334-4394-4ED6-B417-F67FC92228AE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:pn\\/pn_coupler_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "32BD232D-A6BB-4D7B-BD00-1085D08D8A77",
              "versionEndExcluding": "4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:pn\\/pn_coupler:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB2846BD-9DAB-44A2-87C9-39E3ACFE03FA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0FE40195-DE5A-4B9C-9455-FAF92FF090D0",
              "versionEndExcluding": "4.1.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:4.1.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "9B339839-3D74-4E13-9EB6-24CA46F991A5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:dk_standard_ethernet_controller:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "53DF35F1-94FF-4D0B-9FA2-E8B0AFAEA5FF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ek-ertec_200p_pn_io_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9329BF4-D00A-4138-AA4C-93022002C0B9",
              "versionEndExcluding": "4.4.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:ek-ertec_200p_pn_io_firmware:4.4.0:-:*:*:*:*:*:*",
              "matchCriteriaId": "7863DDDC-D5CE-44FE-89C4-0E8A702A91A8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ek-ertec_200p_pn_io:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E62802E3-AFA3-4023-9671-95C220397956",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ek-ertec_200_pn_io_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8C46E084-9732-4920-86C2-3A91830CBCE3",
              "versionEndExcluding": "4.2.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:ek-ertec_200_pn_io_firmware:4.2.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "18C8B2FB-87C3-4DBB-9960-53FA545F26CB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ek-ertec_200_pn_io:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "42D3FAF4-9B78-4EEF-8D80-17E9B98228D2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-200_smart_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "251EE4B2-F1C7-4ACF-B90D-4C0FE3D181E5",
              "versionEndExcluding": "2.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-200_smart:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "598EEFC9-5240-4011-9017-A9557585AA19",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-300_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9461CADE-1624-4D1B-8CF2-CF65F75071C0",
              "versionEndExcluding": "3.3.17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-300:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7EFD4E99-5C66-443F-8B6F-FA01C895DE78",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-400_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2570E321-C28E-46FA-8693-1230B3B5FD1B",
              "versionEndExcluding": "6.0.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-400:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F97B67B-4516-4AD9-B33C-7F480EE0DB4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "582B49BD-4565-4D19-BBE6-A193BDFCE8B0",
              "versionEndExcluding": "4.2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EC545350-FD53-4B2E-886F-E20F12260C9B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D24953B-B3DF-4150-810C-64A94A55E829",
              "versionEndExcluding": "2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "30DDEA9B-E1BF-4572-8E12-D13C54603E77",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "80BDBB38-20D2-48C3-8B58-62C2D8CC00B8",
              "versionEndExcluding": "2010",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:2010:-:*:*:*:*:*:*",
              "matchCriteriaId": "EA59D713-F342-4CDA-BDC8-108352D385DA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_winac_rtx:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA5ADAB0-3985-4933-8CDD-D1546D8271CC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sirius_act_3su1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E36412A-1AAB-42D1-B0B4-7A7BBF3CB317",
              "versionEndExcluding": "1.1.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sirius_act_3su1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8582A3E8-C05E-4D0B-851D-8C3181ED61CC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sirius_soft_starter_3rw44_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F84A65E6-4672-4B62-826E-6FAAE0B4A89D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sirius_soft_starter_3rw44_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBB058FA-3E70-4489-AAB1-0CB7EF16A2E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sirius_motor_starter_m200d_profinet_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3D42184E-8998-4C40-9612-5C9DE193CC06",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sirius_motor_starter_m200d_profinet:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BA5CB62E-04B7-4DD3-AA06-EB4A4FA58E54",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simocode_pro_v_profinet_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "98FDB53A-8F5D-46AA-9366-F6480B12D744",
              "versionEndExcluding": "2.0.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simocode_pro_v_profinet:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "352651A0-F7CE-4689-8597-15F3764707A9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_dcm_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FD2943F3-C46C-462E-9062-EE7B3E56CF72",
              "versionEndExcluding": "1.4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_dcm_firmware:1.4:-:*:*:*:*:*:*",
              "matchCriteriaId": "975EFBBB-33E1-4D04-9E06-93553D45539C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1A43D34-ECA3-4330-B85F-02BDD1D22149",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_dcp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D7A7140-62A2-434F-AB79-1D47C918F1FE",
              "versionEndExcluding": "1.2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_dcp_firmware:1.2:-:*:*:*:*:*:*",
              "matchCriteriaId": "A2B61A79-C2B0-4C3D-A63C-B20FF78B2981",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B75F50CA-7371-4BC7-8D8A-13F8BC69E4EB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g110m_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "775C90BB-C026-435C-889A-517EF85656C5",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g110m_firmware:4.7:-:*:*:*:*:*:*",
              "matchCriteriaId": "CAA92AC6-7DA0-418D-A13F-69268DFD7966",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D61D3E9C-1346-4354-BCD9-B02F67500C41",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g120\\(c\\/p\\/d\\)_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "21ED7835-5D9B-4AF0-8E71-A4E7377FAD9F",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_g120\\(c\\/p\\/d\\)_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "64E77B7F-3E48-4C2C-9E2E-4AAEA6BCA71A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g130_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B3B0706-47CD-43FB-8E3A-7EEEF020AFBA",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g130_firmware:4.7:-:*:*:*:*:*:*",
              "matchCriteriaId": "1D36CF8D-6DA4-49ED-9EF1-F96292F671EE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "373DBE44-AC28-4D04-93BB-35CD8C60E899",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g150_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AC731378-CB83-4C15-BC6A-5A86DF9B62F1",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g150_firmware:4.7:-:*:*:*:*:*:*",
              "matchCriteriaId": "51A78A0B-5D75-418A-98AC-6EBF50D89A8A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2296CA65-0E89-4BCB-8003-E7212BF1F585",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s110_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "35B36BC1-EE75-48D5-B511-C79891DA0F86",
              "versionEndExcluding": "4.4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s110_pn_firmware:4.4:-:*:*:*:*:*:*",
              "matchCriteriaId": "8C21EF20-693C-425F-A370-E84722856212",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_s110_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A4D7197E-C921-42CA-BE43-C96A4223F443",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "77A0BE57-1A9A-4564-9C53-CF47DEEF7991",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:4.7:-:*:*:*:*:*:*",
              "matchCriteriaId": "376556D0-1AE2-4F80-B3CE-C0251E35C326",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5A824BD-935F-4E53-8313-C5544B0489C7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s150_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "772FF972-2193-4639-B454-F92762E49C39",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s150_firmware:4.7:-:*:*:*:*:*:*",
              "matchCriteriaId": "EE2B31F0-D45F-4B42-95D2-540C68C5F3DE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_s150:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D48682C-A39D-4A09-B904-50FA64A9D2A5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_v90_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8EE54303-4FDA-42C7-B33B-BA884CD31339",
              "versionEndExcluding": "1.01",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_v90_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D870F289-F2BC-4105-A8F0-30E47CDE9FEF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simotion_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "92A7198A-D6C5-4FBF-8860-5C8EA864718B",
              "versionEndExcluding": "4.5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simotion_firmware:4.5:-:*:*:*:*:*:*",
              "matchCriteriaId": "B5DA6BF7-ECB8-47F1-A791-E65CFF89A608",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simotion:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "879CF09E-4735-4A73-8E7B-215F2701F7E0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_828d_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "71CD07D8-ECED-47EF-B2BC-0585F9BB00C1",
              "versionEndExcluding": "4.5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_828d_firmware:4.5:-:*:*:*:*:*:*",
              "matchCriteriaId": "AEB948AA-7BD7-4A0F-B86E-38ECD722C086",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinumerik_828d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7D97047C-9772-4AEB-B993-131EBBAE33BA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "28E3AB24-86B4-485D-8D3A-131E5C7F0108",
              "versionEndExcluding": "4.5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:4.5:-:*:*:*:*:*:*",
              "matchCriteriaId": "40AC387B-B799-4A34-8C9E-73D05B86801D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "765286DF-07EC-4C7A-AB8C-09559CD977EA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CE53BC8E-CDA7-476A-87CA-532F365C79A7",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BCFE761-35C9-43EF-85BC-E8083B9F75CB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_multi_panels:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1150AED-CDBE-492C-95FF-3E02B3B447F1",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_multi_panels:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1AAE6A83-737B-47A9-86BB-652C7F6A8013",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_mobile_panels:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "42E8D21B-9CF4-4C2E-B33C-212BA29C7124",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_mobile_panels:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "55E03180-BE77-4A22-A6C1-FE90B9760570",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "02610368-4B97-4B3F-8592-64CF8F65D8AD",
              "versionEndExcluding": "2.1.82",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "61E7964A-E7A4-4CDE-B376-5BBEC5F00A73",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_iec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BE5003DA-5488-47C1-B442-9137E849FDD5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1_iec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFE96226-A2DF-4A9E-8CBB-8D7CF328E404",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_dnp3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FCF9D803-FF47-4400-B2C4-1F4EE28E5AA8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FFBFB96-1A35-4724-831B-68E3A9C32921",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cm_1542sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8BF91884-7532-4E15-A754-EBC430FD0E9D",
              "versionEndExcluding": "1.0.15",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cm_1542sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "921D7568-9FE9-4491-B099-A922984351DC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "64D5B21D-0DC1-479B-810B-21E78F34A80A",
              "versionEndExcluding": "2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_828d_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "45B42950-8BD9-4933-9615-27FCC67C03A1",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_828d_firmware:4.7:-:*:*:*:*:*:*",
              "matchCriteriaId": "86ADBE36-CC1F-4F3C-81CA-ABA0F40AC212",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinumerik_828d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7D97047C-9772-4AEB-B993-131EBBAE33BA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6377EA6B-8EE3-4208-8FB0-175684A77B3F",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:4.7:-:*:*:*:*:*:*",
              "matchCriteriaId": "D5AE6E9A-02B9-4A69-ACC4-EFBE1767E51E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "765286DF-07EC-4C7A-AB8C-09559CD977EA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D87643C3-6525-4CBD-BC0C-6B4DC30C8642",
              "versionEndExcluding": "1.1.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_tdc_cpu555:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE6AB995-D67B-43E5-B8FF-97C38D20CB10",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5C936A7A-1AF9-44E4-9CEC-0694A424616B",
              "versionEndExcluding": "1.1.8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_tdc_cp51m1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8DA1E7C4-6352-41A4-8A94-C24DDB456572",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected."
    },
    {
      "lang": "es",
      "value": "Los paquetes PROFINET DCP especialmente dise\u00f1ados que se env\u00edan en un segmento Ethernet local (capa 2) a un producto afectado podr\u00edan causar una condici\u00f3n de denegaci\u00f3n de servicio de ese producto. Se requiere la interacci\u00f3n humana para recuperar el sistema. Las interfaces PROFIBUS no est\u00e1n afectadas. Esta vulnerabilidad s\u00f3lo afecta a los SIMATIC HMI Multi Panels y HMI Mobile Panels, y a los dispositivos S7-300/S7-400"
    }
  ],
  "id": "CVE-2017-2681",
  "lastModified": "2025-04-20T01:37:25.860",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "ADJACENT_NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 6.1,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 6.5,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "[email protected]",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "[email protected]",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "[email protected]",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "ADJACENT",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 7.1,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "NONE",
          "vulnIntegrityImpact": "NONE",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "[email protected]",
        "type": "Secondary"
      }
    ]
  },
  "published": "2017-05-11T10:29:00.180",
  "references": [
    {
      "source": "[email protected]",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/98369"
    },
    {
      "source": "[email protected]",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securitytracker.com/id/1038463"
    },
    {
      "source": "[email protected]",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html"
    },
    {
      "source": "[email protected]",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
    },
    {
      "source": "[email protected]",
      "tags": [
        "Broken Link"
      ],
      "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/98369"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securitytracker.com/id/1038463"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Broken Link"
      ],
      "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf"
    }
  ],
  "sourceIdentifier": "[email protected]",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-400"
        }
      ],
      "source": "[email protected]",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-400"
        }
      ],
      "source": "[email protected]",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2019-10-10 14:15
Modified
2024-11-21 04:20
Summary
An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation.
Impacted products
Vendor Product Version
siemens cp1604_firmware *
siemens cp1604 -
siemens cp1616_firmware *
siemens cp1616 -
siemens dk_standard_ethernet_controller_firmware *
siemens dk_standard_ethernet_controller_firmware 4.1.1
siemens dk_standard_ethernet_controller_firmware 4.1.1
siemens dk_standard_ethernet_controller -
siemens ek-ertec_200_firmware *
siemens ek-ertec_200_firmware 4.5.0
siemens ek-ertec_200 -
siemens ek-ertec_200p_firmware *
siemens ek-ertec_200p -
siemens scalance_x-200irt_firmware *
siemens scalance_x-200irt -
siemens simatic_et_200m_firmware *
siemens simatic_et_200m -
siemens simatic_et_200s_firmware *
siemens simatic_et_200s -
siemens simatic_et_200ecopn_firmware *
siemens simatic_et_200ecopn -
siemens simatic_pn\/pn_coupler_6es7158-3ad01-0xa0_firmware *
siemens simatic_pn\/pn_coupler_6es7158-3ad01-0xa0 -
siemens simatic_s7-300_cpu_firmware *
siemens simatic_s7-300_cpu -
siemens simatic_s7-300_cpu_312_ifm_firmware *
siemens simatic_s7-300_cpu_312_ifm -
siemens simatic_s7-300_cpu_313_firmware *
siemens simatic_s7-300_cpu_313 -
siemens simatic_s7-300_cpu_314_firmware *
siemens simatic_s7-300_cpu_314 -
siemens simatic_s7-300_cpu_314_ifm_firmware *
siemens simatic_s7-300_cpu_314_ifm -
siemens simatic_s7-300_cpu_315_firmware *
siemens simatic_s7-300_cpu_315 -
siemens simatic_s7-300_cpu_315-2_dp_firmware *
siemens simatic_s7-300_cpu_315-2_dp -
siemens simatic_s7-300_cpu_316-2_dp_firmware *
siemens simatic_s7-300_cpu_316-2_dp -
siemens simatic_s7-300_cpu_318-2_firmware *
siemens simatic_s7-300_cpu_318-2 -
siemens simatic_s7-400_v6_firmware *
siemens simatic_s7-400_v6 -
siemens simatic_s7-400_pn_v7_firmware *
siemens simatic_s7-400_pn_v7 -
siemens simatic_s7-400_dp_v7_firmware *
siemens simatic_s7-400_dp_v7 -
siemens simatic_winac_rtx_\(f\)_firmware *
siemens simatic_winac_rtx_\(f\)_firmware 2010
siemens simatic_winac_rtx_\(f\)_firmware 2010
siemens simatic_winac_rtx_\(f\)_firmware 2010
siemens simatic_winac_rtx_\(f\) -
siemens simotion_firmware *
siemens simotion -
siemens sinamics_dcm_firmware *
siemens sinamics_dcm_firmware 1.5
siemens sinamics_dcm -
siemens sinamics_dcp_firmware *
siemens sinamics_dcp -
siemens sinamics_g110m_firmware *
siemens sinamics_g110m_firmware 4.7
siemens sinamics_g110m -
siemens sinamics_g120_firmware *
siemens sinamics_g120_firmware 4.7
siemens sinamics_g120 -
siemens sinamics_g130_firmware *
siemens sinamics_g130_firmware 4.7
siemens sinamics_g130 -
siemens sinamics_g150_firmware *
siemens sinamics_g150 -
siemens sinamics_gh150_firmware *
siemens sinamics_gh150_firmware 4.8
siemens sinamics_gh150 -
siemens sinamics_gl150_firmware *
siemens sinamics_gl150_firmware 4.8
siemens sinamics_gl150 -
siemens sinamics_gm150_firmware *
siemens sinamics_gm150_firmware 4.8
siemens sinamics_gm150 -
siemens sinamics_s110_firmware *
siemens sinamics_s110 -
siemens sinamics_s120_firmware *
siemens sinamics_s120_firmware 4.7
siemens sinamics_s120 -
siemens sinamics_s150_firmware *
siemens sinamics_s150 -
siemens sinamics_sl150_firmware *
siemens sinamics_sl150_firmware 4.7
siemens sinamics_sl150 -
siemens sinamics_sm120_firmware *
siemens sinamics_sm120 -
siemens sinumerik_828d *
siemens sinumerik_828d 4.8
siemens sinumerik_828d 4.8
siemens sinumerik_828d 4.8
siemens sinumerik_828d 4.8
siemens sinumerik_828d 4.8
siemens sinumerik_840d_sl *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cp1604_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1D00494F-8BC7-44C1-816E-0266920F8659",
              "versionEndExcluding": "2.8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cp1604:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6222006F-09D7-49F7-B8C7-4D94298A8F6A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cp1616_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B1E2552-2661-40FB-A88A-4383064A58F3",
              "versionEndExcluding": "2.8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cp1616:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "184365A2-BAD2-4926-ACEE-F71E018D3CE5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0FE40195-DE5A-4B9C-9455-FAF92FF090D0",
              "versionEndExcluding": "4.1.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:4.1.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "9B339839-3D74-4E13-9EB6-24CA46F991A5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:4.1.1:p4:*:*:*:*:*:*",
              "matchCriteriaId": "92416826-BD34-4611-A5FE-F315C9E8727F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:dk_standard_ethernet_controller:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "53DF35F1-94FF-4D0B-9FA2-E8B0AFAEA5FF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ek-ertec_200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "191FC7FB-791D-44E9-99C8-6CE15C99D057",
              "versionEndExcluding": "4.5.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:ek-ertec_200_firmware:4.5.0:-:*:*:*:*:*:*",
              "matchCriteriaId": "F894A35F-CB1A-4653-9157-DBCE16247D09",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ek-ertec_200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B47CF3BB-08E4-4B86-B793-8253C172D846",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ek-ertec_200p_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D2859C30-0E12-437E-A07A-7B25D841CFDE",
              "versionEndExcluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ek-ertec_200p:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB75CD44-5223-40A7-A835-111BF3C25D23",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x-200irt_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E299AC3-800C-4C27-956A-C7B8DF5F00D0",
              "versionEndExcluding": "5.2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x-200irt:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "94C7BE35-D3A6-488C-BB3D-D17D65DF4B80",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200m_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "14E56570-5C20-40BD-BF0B-F6ED06AFC8F7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200m:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7037E46B-4FE5-4693-B6A6-B5AF7B652C4F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200s_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BB063929-AAB0-4FF8-BCA3-71BA80517B1A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1EC40E7-F004-446C-B5C9-0AB9911105E0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200ecopn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3EE0B998-E408-408F-8F78-5E90F74E9C9B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200ecopn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0259EAE9-0CA0-49A5-A573-8339604A181B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_pn\\/pn_coupler_6es7158-3ad01-0xa0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "17C73DE7-4462-4C7B-8475-D5E6075C8E00",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_pn\\/pn_coupler_6es7158-3ad01-0xa0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2155DBBF-98F3-42A2-8DB1-0BB27984D0E0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C87674A8-B518-4910-B03D-FFF4D5A7B627",
              "versionEndExcluding": "3.3.17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "602FB384-0DB2-488C-B3CC-96E3A2882976",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_312_ifm_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7B0C6327-7BF6-4B96-82A8-D750007869EE",
              "versionEndExcluding": "3.3.17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_312_ifm:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CCFCAA2B-71FE-4DB4-B8B0-F5FD1254C331",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_313_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3EF9F3FB-FBBA-42A8-9A90-FE34703274B5",
              "versionEndExcluding": "3.3.17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_313:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E6E900F-63C1-4E50-9DCD-26CE760E5275",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_314_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F2F0659-CD37-4AA9-B7D5-44639515533C",
              "versionEndExcluding": "3.3.17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_314:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "78399465-EED5-4EBD-A2E1-6FE0BD01EDB4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_314_ifm_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "07AD63B6-B05C-4BBF-812D-379C4D8F8CC7",
              "versionEndExcluding": "3.3.17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_314_ifm:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8BE7963C-7AFF-495B-9F0B-28FB393443FD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_315_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F2A0C75-E360-4E3D-85DA-878E39054E26",
              "versionEndExcluding": "3.3.17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_315:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E3962681-E32E-4BD1-8C71-8768248691D4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_315-2_dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "488F0774-43DA-455D-905C-C514A0192260",
              "versionEndExcluding": "3.3.17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_315-2_dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E8FD8E6D-0527-4215-B6F0-5824011433FB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_316-2_dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F103C351-99C9-4F7D-B69A-D8A876F57504",
              "versionEndExcluding": "3.3.17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_316-2_dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "644AD6A8-AEDE-4F1C-92F8-836877A81310",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_318-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BA99549B-5E95-445A-A95B-1CDA7014686B",
              "versionEndExcluding": "3.3.17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_318-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF58C652-E74D-4B57-A7C5-08D7446863D5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-400_v6_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7B2893A-F0B4-4795-AF1C-DFF17D493929",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-400_v6:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A6445275-2AEF-4285-BE7A-67F20182481C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-400_pn_v7_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1B6B9D8B-D7BA-4D72-97C7-7BBEB49802F7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-400_pn_v7:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E4F8215E-E737-4CD5-B7D9-57FE4A2A2FE5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-400_dp_v7_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "72F7B870-35A1-4900-8104-1303F291E29A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-400_dp_v7:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ABE9F7D2-22C7-4E7C-99C3-4A88CDD2CDB7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_winac_rtx_\\(f\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D03BD73-51ED-42E0-A552-C32BB7A935B2",
              "versionEndExcluding": "2010",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_winac_rtx_\\(f\\)_firmware:2010:-:*:*:*:*:*:*",
              "matchCriteriaId": "7151A19C-0AE5-4F66-9E3D-8BF675A8430C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_winac_rtx_\\(f\\)_firmware:2010:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "BEEB72F4-AE57-49DD-8876-1BCA7B805692",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_winac_rtx_\\(f\\)_firmware:2010:sp2:*:*:*:*:*:*",
              "matchCriteriaId": "7929F123-AC76-4F49-940F-558CABC25E75",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_winac_rtx_\\(f\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C6143A7A-9D01-4D13-B0F5-2AD0DD6DA5EE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simotion_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "080E9ADC-C88F-45D4-8453-6E5E25371476",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simotion:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "879CF09E-4735-4A73-8E7B-215F2701F7E0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_dcm_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "84B1F9B1-4248-4A4C-A8BB-77475A0E9B9B",
              "versionEndExcluding": "1.5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_dcm_firmware:1.5:-:*:*:*:*:*:*",
              "matchCriteriaId": "F2F99FFB-C312-4080-9580-84AFB7C9FA09",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1A43D34-ECA3-4330-B85F-02BDD1D22149",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_dcp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "83803F1C-4842-43BB-B903-C2E91FF7DC08",
              "versionEndExcluding": "1.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B75F50CA-7371-4BC7-8D8A-13F8BC69E4EB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g110m_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "775C90BB-C026-435C-889A-517EF85656C5",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g110m_firmware:4.7:-:*:*:*:*:*:*",
              "matchCriteriaId": "CAA92AC6-7DA0-418D-A13F-69268DFD7966",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D61D3E9C-1346-4354-BCD9-B02F67500C41",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g120_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B1DBCA1A-27F3-4E9A-9F89-65E82A68DE4A",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g120_firmware:4.7:-:*:*:*:*:*:*",
              "matchCriteriaId": "94CB2F3E-AAA1-4472-BFD4-4E6E1B663FF5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_g120:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "61A60DCE-384B-43A4-A669-973FB8ECA932",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g130_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B3B0706-47CD-43FB-8E3A-7EEEF020AFBA",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g130_firmware:4.7:-:*:*:*:*:*:*",
              "matchCriteriaId": "1D36CF8D-6DA4-49ED-9EF1-F96292F671EE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "373DBE44-AC28-4D04-93BB-35CD8C60E899",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g150_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "07F8091F-C17A-4913-A1BC-A7BA376B595F",
              "versionEndExcluding": "4.8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2296CA65-0E89-4BCB-8003-E7212BF1F585",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E231DE7-8B8D-41A3-A163-CE8EF50AF9D0",
              "versionEndExcluding": "4.8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_gh150_firmware:4.8:-:*:*:*:*:*:*",
              "matchCriteriaId": "6D076504-AFE3-4C51-80E5-C5992CA7D511",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BF977545-395A-4C34-BB22-A1047B5B6E85",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3653DA37-DB23-41E0-8CE8-838E384AA40A",
              "versionEndExcluding": "4.8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:4.8:-:*:*:*:*:*:*",
              "matchCriteriaId": "0F86A334-10F9-4DFB-A421-CBCAFD86C8C2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DED7F33B-D475-4232-8683-48554A6729F7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0E25804D-D943-4C2A-9C78-AAC61F7BA4FF",
              "versionEndExcluding": "4.8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:4.8:-:*:*:*:*:*:*",
              "matchCriteriaId": "06B69CD4-3AEC-4014-81DB-33805A44A5D3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s110_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "243FFEA3-7193-45EA-B865-E9CA1D6656FE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_s110:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6218802E-D3B1-4197-A6B5-7343A50F7D88",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "77A0BE57-1A9A-4564-9C53-CF47DEEF7991",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:4.7:-:*:*:*:*:*:*",
              "matchCriteriaId": "376556D0-1AE2-4F80-B3CE-C0251E35C326",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5A824BD-935F-4E53-8313-C5544B0489C7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s150_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "22AFC8AE-8AF0-4418-B251-4CE293B9DCD8",
              "versionEndExcluding": "4.8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_s150:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D48682C-A39D-4A09-B904-50FA64A9D2A5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "30E52510-9306-42B8-A517-A6BBD34B8B9D",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:4.7:-:*:*:*:*:*:*",
              "matchCriteriaId": "58A71910-E54F-426B-BAB1-260AEFD8EF6E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C6619B0F-7CDC-40A6-89B2-C6067AF45214",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CFFE3048-EEB0-48A0-BED0-8647284B022B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "444DD77F-DB65-4766-A89D-7A679B4CA1E1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:sinumerik_828d:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "328F0192-B34D-481C-8964-226317439966",
              "versionEndExcluding": "4.8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinumerik_828d:4.8:-:*:*:*:*:*:*",
              "matchCriteriaId": "C7936CF6-DC07-4550-9FEC-823A2F49096D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "BEE7D914-F2DE-4D8C-BFB2-7AD16650CD3F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp2:*:*:*:*:*:*",
              "matchCriteriaId": "BDBAEDBC-6A76-495D-9BC7-BA687F32EE40",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp3:*:*:*:*:*:*",
              "matchCriteriaId": "45EF769B-1EB1-4D2D-84C5-8005EF1EE1EF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp4:*:*:*:*:*:*",
              "matchCriteriaId": "48EE5859-5450-4078-94E7-E525B999A837",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:sinumerik_840d_sl:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9FFC86D6-F312-4097-91A6-79C78502323F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en Development/Evaluation Kits para PROFINET IO: DK Standard Ethernet Controller (Todas las versiones anteriores a la versi\u00f3n V4.1.1 Patch 05), Development/Evaluation Kits para PROFINET IO: EK-ERTEC 200 (Todas las versiones anteriores a la versi\u00f3n V4.5.0 Patch 01), Development/Evaluation Kits para PROFINET IO: EK-ERTEC 200P (Todas las versiones anteriores a la versi\u00f3n V4.5.0), familia de switches SCALANCE X-200IRT (incluidas las variantes SIPLUS NET) (Todas las versiones anteriores a la versi\u00f3n V5.2.1), SIMATIC ET200M (incluidas las variantes SIPLUS) (Todas las versiones), SIMATIC ET200S (incluidas las variantes SIPLUS) (Todas las versiones), SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12 (Todas las versiones), SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12 (Todas las versiones), SIMATIC ET200ecoPN, 4AO U/I 4xM12 (Todas las versiones), SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12 (Todas las versiones), SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12 (Todas las versiones), SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12 (Todas las versiones), SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12 (Todas las versiones), SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12 (Todas las versiones), SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12 (Todas las versiones), SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12 (Todas las versiones), SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12 (Todas las versiones), SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12 (Todas las versiones), SIMATIC ET200ecoPN: IO-Link Master (Todas las versiones), SIMATIC ET200pro (Todas las versiones), SIMATIC NET CP 1604 (Todas las versiones anteriores a la versi\u00f3n V2.8), SIMATIC NET CP 1616 (Todas las versiones anteriores a la versi\u00f3n V2.8), SIMATIC PN/PN Coupler 6ES7158-3AD01-0XA0 (incluida la variante SIPLUS NET) (Todas las versiones), familia SIMATIC S7-300 CPU (incluyendo las variantes relacionadas ET200 CPUs y SIPLUS) (Todas las versiones anteriores a la versi\u00f3n V3.X.17), familia SIMATIC S7-400 PN/DP V6 y anteriores CPU (incluidas las variantes SIPLUS) (Todas las versiones), familia SIMATIC S7-400 PN/DP V7 CPU (incluidas las variantes SIPLUS) (Todas las versiones), SIMATIC WinAC RTX (F) 2010 (Todas las versiones anteriores a la versi\u00f3n SIMATIC WinAC RTX 2010 SP3), SIMOTION (incluidas las variantes SIPLUS) (Todas las versiones), SINAMICS DCM (Todas las versiones anteriores a la versi\u00f3n V1.5 HF1), SINAMICS DCP (Todas las versiones anteriores a la versi\u00f3n V1.3), SINAMICS G110M V4.7 Control Unit (Todas las versiones anteriores a la versi\u00f3n V4.7 SP10 HF5), SINAMICS G120 V4.7 Control Unit (incluidas las variantes SIPLUS) (Todas las versiones anteriores a la versi\u00f3n V4.7 SP10 HF5), SINAMICS G130 V4.7 Control Unit (Todas las versiones anteriores a la versi\u00f3n V4.7 HF29), SINAMICS G150 Control Unit (Todas las versiones anteriores a la versi\u00f3n V4.8), SINAMICS GH150 V4.7 Control Unit (Todas las versiones), SINAMICS GL150 V4.7 Control Unit (Todas las versiones), SINAMICS GM150 V4.7 Control Unit (Todas las versiones), SINAMICS S110 Control Unit (Todas las versiones), SINAMICS S120 V4.7 Control Unit and CBE20 (incluidas las variantes SIPLUS) (Todas las versiones anteriores a la versi\u00f3n V4.7 HF34), SINAMICS S150 Control Unit (Todas las versiones anteriores a la versi\u00f3n V4.8), SINAMICS SL150 V4.7 Control Unit (Todas las versiones anteriores a la versi\u00f3n V4.7 HF33), SINAMICS SM120 V4.7 Control Unit (Todas las versiones), SINUMERIK 828D (Todas las versiones anteriores a la versi\u00f3n V4.8 SP5), SINUMERIK 840D sl (Todas las versiones). Un atacante con acceso de red a un producto afectado puede causar una condici\u00f3n de denegaci\u00f3n de servicio al romper la sincronizaci\u00f3n en tiempo real (IRT) de la instalaci\u00f3n afectada. La vulnerabilidad de seguridad podr\u00eda ser explotada por un atacante no autenticado con acceso de red a la instalaci\u00f3n afectada. No se requiere interacci\u00f3n del usuario para explotar esta vulnerabilidad de seguridad. La vulnerabilidad afecta la disponibilidad de las instalaciones afectadas"
    }
  ],
  "id": "CVE-2019-10923",
  "lastModified": "2024-11-21T04:20:09.600",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 5.0,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "[email protected]",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "[email protected]",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "[email protected]",
        "type": "Secondary"
      }
    ]
  },
  "published": "2019-10-10T14:15:14.503",
  "references": [
    {
      "source": "[email protected]",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-349422.html"
    },
    {
      "source": "[email protected]",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-349422.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-349422.pdf"
    }
  ],
  "sourceIdentifier": "[email protected]",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-400"
        }
      ],
      "source": "[email protected]",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-400"
        }
      ],
      "source": "[email protected]",
      "type": "Secondary"
    }
  ]
}

OSZAR »